Forwards Final Deficiency Rept Re Radiographic Exam of Hartsville Drywell Vent Structure & Phipps Bend Reactor Pressure Vessel Pedestal Weld Buildup
ML19296C662
Person / Time
Site: Hartsville, Phipps Bend  
Issue date: 02/15/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19296C663 List:
References
NCR-S-13, NCR-S-7, NUDOCS 8002270344
Download: ML19296C662 (1)


Text

,

.g TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374o1 400 Chestnut Street Tower II February 15, 1980 Mr. James P. O'Reilly, Director Of fice of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS - REPORTABLE DEFICIENCY -

RADIOGRAPHIC EXAMINATION OF HARTSVILLE DRYWELL VENT STRUCTURE AND FliIPPS BEND REACTOR PRESSURE VESSEL-PEDESTAL (NCR S-7 AND S-13)

Initial report of the subject deficiency was made to R. W. Wright on January 15, 1980.

In compliance with paragraph 50.55(e) of 10 CFR Part 50, we are enclosing the final report of the subject deficiency.

If you have any questions regarding this subject, please call Jim Domer at FTS 854-2014.

Very truly yours, TENNESSEE VALLEY AUTHORITY r

L. M. Mills, Manager Nuclear Regulation and Safety Enclosure cc:

Mr. Victor Stello, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 a

c

'