Forwards IE Bulletin 80-04, Analysis of PWR Main Steam Line Break W/Continued Feedwater Addition. Written Response Required
ML19296C349
Person / Time
Site: Yankee Rowe
Issue date: 02/08/1980
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Ray J
YANKEE ATOMIC ELECTRIC CO.
References
NUDOCS 8002250637
Download: ML19296C349 (1)


Text

@o E ' g( jo UNITED STATES g

g NUCLEAR REGULATORY COMMISSION g

9 r REGION I 631 PARK AVENUE KINO OF PRUSSIA, PENNSYLVANIA 19406 Docket No. 50-29 Yankee Atomic Electric Company ATTN:

Mr. James A. Kay Senior Engineer - Licensing 25 Research Drive Westborough, Massachusetts 01581 Gentlemen:

The enclosed IE Bulletin No. 80-04, is forwarded for action. A written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely,

/ WM r

Boyce H. Grier Director

Enclosures:

1.

IE Bulletin No. 80-04 2.

List of Recently Issued IE Bulletins CONTACT:

D. L. Caphcon (215-337-5253) cc w/encls:

H. Autio, Plant Superintendent J. E. Tribble, President bud 2250C3 l

ENCLOSURE 1 UNITED STATES SSINS No.:

6820 NUCLEAR REGULATORY COMMISSION Accessions No.:

0FFICE OF INSPECTION AND ENFORCEMENT 7910250504 WASHINGTON, D.C.

20555 IE Bulletin No. 80-04 Date: February 8, 1980 Page 1 of 3 ANALYSIS OF A PWR MAIN STEAM LINE BREAK WITH CONTINUED FEEDWATER ADDITION Description of Circumstances:

Virginia Electric and Power Co. submitted a report to the Nuclear Regulatory Commission dated September 7, 1979 that identified a deficiency in the original analysis of containment pressurization as a result of reanalysis of steam line break for North Anna Power Station, Units 3 and 4.

Stone and Webster Engineering Corporation performed a reanalys b of containment pressure following a main steam line break and determined that, if the auxiliary feedwater system continued to supply feedwater at runout conditions to the steam generator that had experienced the steam line break, containment design pressure would be exceeded in approximately 10 minutes.

The long term blowdown of the water supplied under runout conditions by the auxiliary feedwater system had not been considered in the earlier analysis.

On October 1,1979, the foregoing information was provided to all holders of operating licenses and construction permits in IE Information Notice No. 79-24. The Palisades facility did an accident analysis review pursuant to the information in the notice and discovered that with offsite power available, the condensate pumps would feed the affected generator at an excessive rate.

This excessive feed was nut considered in the analysis for the steam line break accident.

On January 30, 1980, Maine Yankee Atomic Power Company informed the NRC of an error in the main steam line break analysis for the Maine Yankee plant.

During a rev5:w of the main steam line break analysis, for zero or low power at the end of core life, the licensee identified an incorrect p. :ulation that the startup feedwater control valves would remain positioned "as is" during the transient.

In reality, the startup feedwater control valves will ramp to 80% full open due to an override signal resulting from the low steam generator pressure reactor trip signal.

Reanalysis of the event shows the opening of the startup valve and associated high feedwater addition to the affected steam generator would cause a rapid reactor cooldown and resultant return-to power, a condition outside the plant design _ba h Actions to be Taken by the Licensee DUPLICATE DOCUMENT For all pressurized water power rea reactors listed in Attachment 1: