s

' (3)

QUAD CITIES NUCLEAR POWER STATION TABLE lA 1978 EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT GASEQUS EFFLUENTS-SUMMATION OF ALL RELEASES Muarter Quarter Est. Total Unit

,,a 4th Error, y, A.

Fission & Activation Gases C1 7,onE+03 5.10r+03 1.

Total release cCi/sec 9.94E+02 6.66E+02 2.

Averace release rate for oeriod Percent of Tech. Shec. limit 3

a.

  • /.

4.32E-02 3.36E-02 Chimnev

b. i Percent of Tech. Spec. limit 4.17E-01 1.llE+00 Stack B.

lodines 4.01E-01 3.15E-01 Ci 1.

Total iodine-131 2.

Averace release rate for period uti/sec 5.04E-02 3.95E-02 3+

a.

Percent of Tech. Spec. limit statior 4.06E+00 l 3.19E+00 C.

Particulates Ci 4.83E-01 3.14E-01 1

Parti culates with half -liv < > 8 davs 2.

Avaraca releasa rate for period uti/sec 6.08E-02 3.96E-02 4.94E-05 1.83E-05 3

Gross alpha radioactivity 790 D 02 0 32 tl

37 '. -

TA3LE 1A CONTINUED 1978 EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT GASEOUS EFFLUENTS-SUMMATICM OF ALL RELEASES Quarter quarter Ett. Total Unit 3rd 4th Error. Y.

D.

Tri t t urn Ci 1.70E+01 1.29E+01 1.

Total release uCi/sec 2.14E+00 1.62E+00

_2. Average relaase rate for oeriod e

D

  • V'l QUAD CITIES huCLEAR PC',lEst STAT 10;i 1B TA3LE EFFLUEfiT A;iD VASTE DISPCSAL SEMI ANNUAL REPO?.T 1978 CASEQUS EFFLUENTS-ELEVATED RELEASE Continuous flode Batch Mode Quartcr Quarter Quarter Quarter Nuciides Released Unit 3rd 4th 1.

Fission gases Kr-89 Ci

<LLD

<LLD Kr-Sc, Ci 3.91E+02 3.29E+02 Kr-R7 Ci

<LLD 1.32E+01 Kr 92 Ci 8.18E+01 5.33E+01 X.-13 3 Ci 6.86E+03 3.96E+03 X e-1 %

Ci 5.16E+02 5.12E+02 Xe-13c, Ci

<LLD

<LLD X -138 Ci 3.94E+01 4.19E+02 Ci Ci Unidantified Ci

<LLD

< LLD Tot,1 for Period Ci 7.90E+03 5."29E+03 2.

lodines 1-131 Ci 3.72E-01 2.83E-01 1-133 Ci 1.69E+00 1.91E+00 Ci 1.90E+00 2.13E+00 1 -1 y Tota 1 for Perind Ci 3.96E+00 4.32E+00

. -.- ~,=~.. --,.-

_- _-.- -.+ - -..---.

17 TA3LE 1B CONTINUED EFFLUEtlT AND WASTE DISPOSAL SEM! A;4NUAL REPORT 1o79 GASEQUS EFFLUENTS-ELEVATED RELEASE Continuous Mode Batch Mode Quarter Quarter Quarter Quarter Nuclides Released Unit 3rd 4th 3

Particulates Cl 1.62E-02 Sr-8o Ci 1.89E-04 Sr c0

~~ C i 6.35E-04 7.67E-04 Cs-134 Ci 1.73E-03 2.36E-03 Cs-137 Cl 5.28E-02 1.23E-01 Ba-lho i

Ci 7.45E-02 1.43E-01 Lo-ILO Cr51 Ci

<LLD

<LLD Mn54 Ci 3.87E-05 2.87E-05 CoS3 Cl

  • <LLD

<LLD Co60 Ci 1.51E-03 1.43E-03 1131 Cl 6.33E-02 8.17E-02 Ag110m Ci

<LLD

<LLD Cl 6.82E-04 1.75E-03 C1 Ci Ci Ci 1.21E-01 Unidentified Ci

dr7 QUA0 CITIES i;UCLEAR POWER STATION 1C TA3LE EFFLUENT AND VASTE DISPOSAL SEMIANNUAL REPORT 1978 GASEOUS EFFLUENTS-GROUND LEVEL RELEASE Continuous Mode Batch Mode Quarter Quarter Quarter Quarter Nuclides Released Unit 3rd 4th 1.

Fission gases Kr-89 Ci

<tto

<tto Kr-8;m CI 2.17E-01 4.94E-01 Kr-87 Ci

<LLD

<LLD K r-83 Ci 6.30E-02 3.11E-02 X a-131 Ci 3.31E+00 4.86E+00 Xe-135 CI 4.04E-01 6.90E-01 X c-13 cm Cl

<LLD

<LLD

..e-138 Ci

<LLD 2.37E+00 Ci Ci Unid-ntified Ci

<LLD

<LLD Total for Period Cl 3,qoE+00 845E*00 2.

todines 1-131 Ci 4.62E-02 3.17E-02 1-133 Ci

1. 74 E-01 1.14E-01 1-135 Ci 5.09E-01 3.63E-01 Total for Pncind Ci 7.29E-01 5.09E-01

~

37 TABLE 1C CONTINUE 0 1978 EFFLUEtiT AND WASTE DISPOSAL CEMI ANNUAL REPORT GASEOUS EFFLUEllTS-GROUND LEVEL RELEASE Batch Hode Continuous Mode

< Quarter Quarter Quarter Quarter Nuclides Released Unit 3rd 4th 3,

Particulates Ci 8.10E-03 Sr-Bo CI 2.06E-04 Sr c0

~CI 2.95E-03 9.71E-04 Cs-134 5.60E-03 1.67E-03 Cl Cs-137 C1 1.95E-02 7.07E-03 Ba-lho Ci 2.70E-02 8.63E-03 La-lho Cr51 C1 1.73E-02 2.11E-03 Mn54 Ci 3.17 E-04 2.46E-05 CoS8 Cl

7. 66E-04 5.64E-05 Co60 CI 6.44E-03 8.24E-04 Il31 Ci 1.30E-03 7.01E-03 Ag110m Ci 3.89E-05 5.83E-06 1.07E-03 1.24E-04 Cs 136 C1 4.58E-04 8.18E-05 l

Zn 65 C;

3.15E-04

8. 34E-05 Ce 141 Ci

<LLD 3.41E-05 Zr 95 C1

<LLD 4.45E-05 Nb 95 CI

<LLD 2.82E-05 Ru 101 Ci Ci 5.66E-02 Unidentified

SIN?

J QUAD CITIES NUCLEAR POWER STATION TABLE 2A 1978 EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES Quarter quarter Est. Total Unit 3rd 4th Error, %

A.

Fission and Activation Products 1.

T *al rai ose (not including ses. afnha)

CJ 3.67E-01 3.05E-01 2

Av~....,2 oiluted concentration uCi /mi 2.49E-09 8.57E0-9 durinn period 3.

Percent of annlicable l'i mi t 2.49E+00 8.57E+00 4

Maximum diluted concentration uCi/ml 3.82E-08 6.44E-08 durinn period B.

Tritium C1 2.89E+00 1.

Total relance 2

Average diluted concentration uCi /nl 1.96E-08 durinn neriod 3.

Percent of annlicabla limit 6.53E-04 l C.

Dissolved and Entrained Gases Ci

<LLD

<LLD 1

Total relante 2

Average diluted concentration uCi /mi

<LLD

<LLD durino period 3.

Percent of anoIIcable limit

<LLD

<LLD j

D.

Gross Alpha Radioactivity

_f.

Total retaase CI 2.44E-04 2.70E-04 2

Averane concentration relensed ut i /ml 1.66E-12 7.58E-12 E.

Volu e o vaste released (prior 3.18E+06 9.llE+05 Liters F.

Volume of dilution water used Liters 1.47E+11 3.56E+10 durinn parind

T)

QUA) CITIES iPJCLES.':.G'/Tl STATIGil TA3LE 20 EFFLUE:IT A.'!9 '.'ASTE Di 3?05AL SE;11 A:;:lU/.L RE?D. T 1978 1

LIQUID EFFLUE lis Centinuous !!ada 3.'+ ch M ode Quarter Quarter Quarter Quarter Unit 3rd 4th Sr-89 Ci 3.75E-03 l

Se oc Ci

6. 47 E-04 Cs-11L C1 4.21E-02 1.72E-02 8.38E-02 3.77E-02 Cs-137 C i-

<LLD

<LLD 1-131 Ci

~

1.50E-02

<LLD Co-5B Ci 2.36E-02 2.68E-02 Co-60 C;

Fa-Go Ci

<LLD

<LLD Zn-69 Ci

<LLD

<LLD tin-64 Ci (LLD 5.14E-04 Cr-;I Ci

<LLD

<LLD

<LLD

<LLD Zr-4; Ci

<LLD

<LLD tjs-os Ci

<LLD

<LLD Mo-co Ci Tc-QCm C;

<LLD

<LLD

<LLD 6.98E-03 Ba-lho Ci

<LLD

<LLD i

C -141 C;

1.89E-02 1.04E-02 La-140 Ci Ci U n i da n t i f i ori Ci 1.79E-01 T o t., : for P e r ind (., mv;.)

Ci 3.67E-01 Ci

<LLD

<LLD xo-!:3 CI

<LLD

<LLD

-. 114

SOLID RADIOACTIVE WASTE

SUMMARY

BSC - Itarnwell South Carolina

~

CN - Cliem Nuclear Co.

QUAD-CITIES STATION lill - liittman Nuclear & Development Co.

DISPOSITION OF MATERIAL VOLUME (ft )

VOLUME (ft )

MILLICURIES CURIES DATE CO. TRANS.

BURIAL SITE PER SilIPMENT PER MONTil PER SilIPMENT PER MONTil 7/03

!!N BSC 105 9629 7/03 IlN BSC 105 10892 7/08 IIN BSC 90 6674 7/10 IIN BSC 105 12036 7/11 IIN IISC 90 8167 7/12 IIN BSC 105 10868 7/12*

IIN BSC 90 8010 7/12 IIN '

BSC 90 9237.5 7/14 IIN IISC 90 9155 7/17 IIN BSC.

90 9007 7/17 IIN BSC 105 11157 7/18

!!N BSC 90 6565 7/19 IIN IISC 90 7035 7/20 llN BSC 90 11144 7/21 llN 11SC 105 8414 7/21 ilN liSC 90 7134

SOLID RADI0 ACTIVE WASTE SUM?fARY BSC - Barnwell South Carolina J"lY - 1978 CN - Chem Nucleac Co.

OUAD-CITIES STATION llN - liittman Nuclear & Developraent Co.

DISPOSITION OF MATERIAL VOLUME (ft )

VOLUME (ft )

MILLICURIES CURIES DATE Co. TRANS.

BURIAL SITE PER SIIIPMENT PER MONTil PER SilIPMENT

?ER MONTH 7/24 IIN BSC 90 967 7/25 llN BSC 105 9027 7/28 IIN BSC 105 7040.5 7/26 IIN BSC 90 5450 7/27 IIN BSC 90 6936.5 7/31 IIN BSC 90 3903 7/31' ilN BSC 90 6063 2190 184,5) e

SOLID RADI0 ACTIVE WASTE SLRelARY liSC - Barnwell South Carolina

^"E"'

~

CN - Cliem Nuclear Co.

OUAD-CITIES STATION llN - liittman Nuclear & Development Co.

DISPOSITION OF MATERIAL V0ttniE (ft )

VOLUME (ft )

MILLICURIES CURIES DATE CO. TRANS.

BURIAL SITE PER SilIPMENT PER MONTil PER SilIPMENT PER MONTil 8/2 IIN BSC 93.87 4611 8/2 IIN BSC 90 5572 8/3 IIN BSC 90 8012 8/7 IIN BSC 97.66 8282 8/7 IIN BSC 90 g4g5 8/9 IlN BSC 90 7000 8/10' ilN BSC 1039.4 293 8/11 IIN BSC 90 8485 8/14 IIN liSC 90 5913 8/14 IIN BSC 90 8407 8/16 IIN BSC 90 8264 8/17 IIN BSC 105.16 5805 8/18 IIN BSC 90 6960 8/18 IIN BSC 90

(> 694

[8/21 IIN BSC 90 11424 i

8/22 IIN liSC 90 7514

SOLID RADI0 ACTIVE WASTE StnefARY UNITS 1/2 August - 1978 llSC - Ilarnwell South Carolina CN - t. hem Nuclear Co.

OUAD-CITIES STATI6N llN - liittinan Nuclear & Development Co.

DISPOSITION OF MATERIAL VOLUME (ft )

VOLUME (ft )

HILLICURIES CURIES DATE Co. TPANS.

BURIAL SITE PER SilIPMENT PER MONTl!

PER SilIPMENT PER MONTH 8/23 IIN BSC 105.16 6558 8/23 IIN BSC 90 6961

~

8/28 IIN BSC 105 8135 8/28 IIN BSC 90 9157 8/29 IIN B.SC 90 6878 2896.25 149.43

SOLID RADIOACTIVE WASTE SifFetARY UNITS 1/2 ltSC - Barnwell South Carolina September - 1978 CN - Chem Nucicar Co.

']UAD-CITIES STATION llN - liittman Nuclear & Development Co.

DISPOSITION OF MATERIAL VOLUME (ft )

VOLUME (ft )

MILLICURIES CURIES DATE CO. TRANS.

BURIAL SITE PER SilIPMENT PER MONTil PER SilIPMENT PER MONTil 9/1 IIN BSC 90 8276 9/1 IIN BSC 105.16 7263 9/5 IIN BSC 90 4742 9/7 IIN BSC 105 10187 9/7 IIN BSC 90 8728 9/8 ilN BSC 90 8129

_9 [

IIN BSC 105 5775 9/13 IIN BSC 90 6432 9/13 IIN BSC 109 6623.6 9/14 IIN BSC 90 4759 9/15 IIN BSC 975 99.46 9/18 ilN BSC 90 8658 9/18 IIN BSC 109.2 10689 9/22 llN BSC So 7444 9/22 IIN liSC 90 841 9/22 IIN llSC 105 6942

{

SOLID RADIOACTIVE WASTE SUMt!ARY UNITS 1/2 BSC - Ilarnwell South Carolina September - 1978

~

CN - Chem Nuclear Co.

QUAD-CITIES STATION llN liittman Nuclear & Development Co.

DISPOSITION OF MATERIAL VOLUME (ft )

VOLUME (ft )

MILLICURIES CURIES DATE CO. TRANS.

BURIAL SITE PER SilIPMENT PER MONTil PER SilIPMENT PER MONTil 9/25

!!N BSC 90 689 9/27 IIN BSC 105 11096.4 9/27 IIN BSC 90 5954 9/28 IIN BSC 105 11458 9/28 IIN BSC 90 7565 2903.36 142.35 m

SOLID RADI0 ACTIVE WASTE SURIARY UNITS 1/2 BSC - Barnwell South Carolina October - 1978 CN - Chem Nuclear Co.

QUAD-CITIES STATION llN - Ilittman Nuclear & Development Co.

DISPOSITION OF MATERIAL t

i VOLUME (ft )

VOLUhE (ft )

MILLICURIES CURIES DATE CO. TRANS.

BURIAL SITE PER SIIIPMENT PER MONTil PER SHIPMENT PER MONTH 10/2 IIN BSC 105.16 4939 10/4 IIN BSC 90 960 10/5 IIN BSC 499.25 72.2 10/6 IIN BSC 40 19474.3

,Q liN R9C 105 91115 10/10 llN BSC 90 10608 10/li llN BSC 105 27833 10/13 IIN' BSC 90 13015 10/16 IIN BSC 109.22 9971 10/18 IIN

!!SC -

105 23083

. 10/18 IIN BSC 581_75 46 7 10/20 IIN BSC 105

??s27 10/20 llN BSC 90 14563 10/25 IIN BSC 105 18495 10/25 IIN BSC 109.22 7716 10/26 IIN ltSC 90 13164

HT SN 0

EO 9

I M 1

R UR 6

CE S

3 P

2 8

7 9

1 T

SN r

EE e

I M b

RP 1

9 o

UI 0

3 t

Ci 2

9 l

c I S 1

4 O

L 2

LR I E MP

)

li T

t N

f O

6

(

M 7

Y E

R 9

R M E 7

A U P 6

M L

2 M

O U

V S

NO E

I T

T S

A A

2 T W / S 1

)

T E

S N

V S E E

6 t

I T

I M

1 f

T I

T P

(

C N

I I

5 5

A U C 0

0 l

Ei 0

S 1

1 I

D M

D A

U R A

U L

E R

Q O

P V

D I

L O

S

.mC t

E n

L T

e A

I m

I S

p R

o E

L C

C a

l T

A S

S n

e A

I B

B i

v M

R l

e U

o D

F B

r O

a.&

e C

N o r O

h Ca I

t e

T r

u l

I a

o c

S e

S u

O l

N P

c l

S S

u n I

N le Na D

A w

m R

N I

nmt T

I N

ret I

I ahi hcl O

i C

CNt 0

SCl E

i 3

2 B

T

/

/

A 0

0 D

1 1

SOLID RADI0 ACTIVE WASTE SUmfARY BSC - Barnwell South Carolina UNITS 1/2 November - 1978 CN - Chem Nuclear Co.

QUAD-CITIES STATION llN - liittman Nuclear & Development Co.

l DISPOSITION OF MATERIAL VOLUME (ft )

VOLUME (ft )

MILLICURIES CURIES DATE Co. TRANS.

BURIAL SITE PER SIIIPMENT PER MONTil PER SilIPMENT PER MONTil 11/1 IIN BSC 105 13948.2 11/2 IIN BSC 830.25 79.89 11/6 IIN BSC 105 14731 11/6 IIN BSC 105 12502 11/9 IIN BSC 105 19452 11/13 IIN BSC 105 19091 11/16 IIN BSC 105 13611 11/17 IIN' BSC 803.26 157.69 11/17 IIN BSC 105 14436 11/21 IIN BSC' 105 8900 11/22 IIN BSC 105 9538 11/28 IIN BSC 105 12782 11/29 IIN BSC 90 4903 11/29 IIN BSC 105.16 8538 11/30 llN BSC 90 7386 2968.67 159.89 4

SOLID RADIOACTIVE WASTE SUMfARY BSC - Barnwell South Carolina UNITS 1/2 December - 1978 C'I - Chem Nuclea-Co.

QUAD-CITIES STATION llN - liittman Nuclear & Development Co.

DISPOSITION OF MATERIAL VOLUME (ft )

VOLUME (ft )

MILLICURIES CURIES DATE CO. TRANS.

BURIAL SITE PER SilIPMENT PER MONTil PER SilIPMENT PER MONTil 12/1 IIN BSC 97.58 11070 12/4 ilN BSC 90 6062 12/5 IIN BSC 90 6821 12/6 IIN BSC 90 5860 12/7 IIN BSC 90 13669 12/8 IIN BSC 105.16 16821 12/8*

1111 BSC 105 20675 12/12 IIN BSC 90 2599.5 12/13 I!N BSC 105 14069.6 12/13 IIN BSC-90 6173 12/18 IIN BSC 105 11348 12/19 IIN BSC 105 16760 12/19 IIN BSC 90 907s 12/20 IIN BSC 90 5763 12/22 IIN BSC 105 14469 12/27 IIN BSC 90 10567

SOLID RADI0 ACTIVE WASTE

SUMMARY

BSC - Barnwell South Carolina UNITS 1/2 December - 1978 CN - Chem Nuclear Co.

QUAD-CITIES STATION llN - liittman Nuclear & Development Co.

DISPOSITION OF MATERIAL VOLUME (ft )

VOLUME (ft )

MILLICURIES CURIES DATE Co. TRANS.

BURIAL SITE PER SilIPMENT PER MONTil PER SilIPMENT PER MONTil 12/27 IIN BSC 90 6285 12/29 liN

!!SC 105 10716 12/29 llN BSC 90 9437 1822.74 188.03

.Tu l y throu h December 6-Month Tota is 15460.78 1060.19 t

Quad Cities Station 1918 Report of Occupational Personnel Radiation Doses Commonwealth Edison Employees Work Function Reactor Operations Routine Maint. &

Job Function

& Surveillance Inservice Inspection Waste Processing Refueling

!/ of people / man-rem

  1. of people / man-rem
  1. of people / man-rem
  1. of people / man-rem Maintenanee 10/23 3 105/255 3 1/1.8 Operating 71/37.6 9/15 3 74/125.1 13/33.0 Health Physics 11/28.4 6/14.8 9/23.1 supervisory 42/27 3 65/57.3 3/1.6 7/2.5 Engineering 144/34.1 I

Contract Workers Maintenance 1808/699 5 Special maintenance Company employees other than station employees:

193/187.8 Special maintenance on installing ACAD/ CAM' modification: pull & inspect CRD nozzle; removed, inspected, and replace sparger; blade guides, cut off and weld en nc< tie plate.