s PALISADES :iUCIJ.AE PCWER PLA?C RADICACTLT. EFFLUE;T AIID WASTE DISPOSAL SE!I-A i';UAL PIPCET JULY - DECEGER 1979
"+m, j
800306
This report provides information relating to radioactive effluent releases and solid radioactive vaste disposal operatiens of the Palisades Plant during the period of July through Dece=ber 1979 in the for=at centained in plant Technics 1 Specification Section 6.9.3 1.A.
1.
Surele= ental Information a.
Batch Peleases Infor=ation relating to batch releases of liquid and gaseous effluents is provided in Table 1.
b.
Abnomal Releases Cne abnormal gaseous release occurred during the reporting period totaling 0.569 Curies. The release a=ounted to less than 35 of the total gaseous releases during the reporting period. The =axi=u= dise to off-site populations fro = this release is calculated to be less than 0.0002 cre=.
No release limits were exceeded.
2.
Gaseous Effluents Table 2a presents a sc==ary of all gasecus radicactive ef fluents released during the period. Release totals for ea:h radienuclide determined to be present in gasecus effluents are contained in Table 2b.
The unidentified portien of the total release was 0.0009% of the total release.
3 licuid Effluents Table 3a presents a s -~/ of all liquid radioactive effluents released during the period. Release totals for each radienuclide deter =ined to be present in liquid effluents are contained in Table 3b.
The unidentified portion of the total release was 0.01", of the total release.
L.
Solid Waste Quantities of solid vaste shipped off-site and the dispcsition of these ship =ents are presented in Table L.
5 Radiological Iract en Man
?ctential doses to individuals and populations were calculated using effluent data centained in Tables 2 and 3, and the dose conversion facters contained in the February / March 1979 Appendix sub=ittal.
Total body and significant organ deses to individuals in unrestricted a.
areas frc= receiving water-related expcsure pathways were calculated to be less than 1 =illire=.
b.
The marimu= off-site air doses due to beta and gs==a radiation at loca-tiens near ground level frc= gaseous effluents vere calculated to be less than 1 millirad.
Organ doses to individuals in unrestricted areas from radioactive iodine c.
and radioactive material in particulate fem frem the major pathways of exposure were calculated to be less than 1 millires for any organ.
d.
Total body doses to the populatien and average doses to individuals in the pcpulation frem receiving water-related pathways to a distance of 50 miles frem the site were calculated to be less than 1 manrem and 1 millires, respectively, Total body doses to the population an:1 average doses to individuals in e.
the population frem gaseous effluents to a distance of 50 miles frem the site were calculated to be less than 1 =anres and millire=, res-pectively.
Tt.PLE I I'ALISADFS fillCLEAR POWER PLANT RA'IUII RELFASES (1979 )
A.
CASEDUS WASTE CAS DFEAY TAtlKS UtilTS TilIRD Qt'ARTER FOtlRTil OlfARTER fiumber of Eelenses 30 1
Total Release Time Minutes 21:12 350 S0 350 l
Maximum Relense Time Minutes 2 81 350 7
Average Relense Time Minutes Minimura Release Time Minuten 35 350 H.
LIQt1ID t
UNITS TillRD QllARTER FotJRTH QtfARTER fiumber of Relenses 11 7
Total Release Time Minutes 5609 3263 Maximum Release Time Minutes p;410 1080 166 Average Release Time Minutes 510 4
Minimum Relenne Time Minutes 75 115 C.
ABil0RMAL RELEASES There van one abnormal ganeous relenne tot.nling 5.69 E-01 Curles.
TA3LE 2a PALISADES NUCLEAR PC'JER PLA'C EFFLUEC AND '4ASTE DISPOSAL SECANNUAL RENRT (L979 )
GASIDUS EFFLUE'ITS - SUMMATION OF ALL RELEASES THIRD FCUR"?.
EST. MTAL, UNITS QUARTER QUARTER ER"OR, %
i A.
FISSION & AC"'IVATION GASES 1.
Total release C1 1,91g+ol 5 06E-02
+ 165 2.
Average release rate fer period pCi/see 2.h3E+00 6.hhE-03 3
Percent of Technical specifiestion 1.66E-03 k.30E-06 Limit B.
IODINE 3 1.
Total iodice-131 Ci
- 7. lee-03 1.c6E-03
+ 5%
2.
Average release rate for period pCi/sec 9,153_ch 1,353_ch (I-131) 3 Percent of Technical specification 6.53E-02 9.63E-03 Limit (I-131)
C.
PARTICLU TES 1.
Particulates with half-lives >8 Ci h.91E-Oh 1.36E-03
-+ 15%
days 2.
Average release rate for period uCi/see 6.25E-05 1.73E-Ch 3
Percent of Technical specification 2.71E-03 6.26E-03 L1=1t k.
Cross alphe radioactivity Ci 1.11E-06 1.62E-06 D.
TRITILM 1.
Total release C1 1.17E+00 2.25E+00 2.
Average release rate for period pCi/see 1.k9E-01 2.86E-01 3
Percent of Technical specification 1.L9E-OL 2.86E-Ch Limit TOTAL C1 2.03E+01 2.30E+00
TA3LE Sh PALISADES :RICLEA.R POWER PL%~"
EFFLUEIT A iD WAJTE DISIOSAL SD4IA mUAL REPORT (:.979 )
CASIDUS EFFLUEITS - GROUiD-LEVEL RELEASES HUCLIDES RELEASED UiITS TH:P3 QUARTER FCURTH QUARTIR 1.
FISSION GASES Arcon kl C1 2.61E-02 Krypton-85 Ci
.___-v_
,3,3 g.,
f Xenon-133 Ci Xenon-135 C1 1.10E-01 Xenon-131m C1 1.25E-01 Xenon-133m Ci 5 21E-03 Total for period C1 1.91E+01 3.06E-02 2.
ICDriES Iodine-131 Ci 7.18E-03 1.06E-03 Iodine-133 C1 2.39E-03 Iodine-135 Ci h 23E-OL Total for period Ci 9.99E-03 1.06E-03 3
PARTICULATES Cesium-134 Ci L.03E-06 5.39E-05 l
3.3kE-05 l
1.67E-OL Ce sium-137 Ci Chro=ium-51 C1 3.32E-06 l
5.75E-05 3.33E-OL Mangenese-54 Ci Cobalt-58 C1 9.5LE-05 1.75E-Ch Cobalt-60 C1 2.23E-Ch k.3SE-Oh
'Tiobiu=-95 Ci 1.LSE-06 tiet Unidentified Beta 01 6.2hE-05 1.36E-Oh z--.
TA3LE %
PAI!SA2ES :.~i'0 LEAR POWER PLtdC EFITUC;T AND WAS'"E DISIOSAL SECAN';UAL REPORT (1979)
LIQJID H'77UE;TS - SLM'.ATION OF ALL RE EASES
!"CRD FCURTR EE. TOTAL UNI'"S C'ARTER QUARTER ER"0R,%
A.
FISSICN AND ACTIVATION PPC:1A7. S 1.
Total release (not including tritium, Ci 9.L6E-02 5 15E-03
+ 6.L5 reses siphs) 2.
AversEe diluted concentrstion during pCi/=1 3.59E-09 3.31E 10 reriod Percent of a;;11 cable limit 1.09E+01
't.02E-01
- 3. TR! TIUM 1.
Total release C1 6.07E+01 2.02E+01 1 5%
2.
Average diluted concentration during pC1/=1 2.5CE-06 1.L9E-06 teried Percent of applicable 11=1t 8.33E+00 L.97E+00 C.
DIS 3OLVED AND DiTRAITZD GASES 1 6.7",
1.
Total release Ci
- 7. 6LE-0 3 2.
Average diluted concentrstion during pCi/=1 3.12E-10 period Percent of applicable 11:10 1 37I-02 D.
CROSS ALPHA RADICAcnet.i 1.
Total release Ci E.
VOIUME OF WASTE RELEASED (PRIOR IO DILUTIDNj Liters h.96E+06 3.k9E+06 F.
VOUJME OF DILUTION WATER USED IURD G PERIOD l Liters2.k3E+10 1.36E+10
TABLE 3b PALISADES ?iUCLEAR PCVER PLA:iT EFFIDHiT AND WASTE DISP] SAL SD4IAN:iUAL REPORT (1979)
LIQUID EFFLUEITS NUCLEES RE1EASD U: TITS THIRD QUAR C, FOURTH OUARTER Ce s iu=- 134 01 1.60E-OL 6.30E-05 C s si=-137 l
Ci 9.17E-Oh 6.37E-Oh
- d ine-131 l
C1 1.90E-05 0 bait-53 Ci 5.26E-02 2.L6E-03 l
1.lhE-02 9.60E-OL C0talt-6C Ci Marganese-Sh C1 S.56E-03 6.2hE-Ch Chromium-51 C1 1.ChE-02 1.63E-Ch Z42:eni=- 95 Ci 5.53E-OL
-=
Niobium-95 C1 1.3LE-03 6.00E-06 FE-59 C1 1.0LE-03 1.10E-05
- Tet Unidentified Beta Ci 7.60E-03 2.55E-OL Total for Period (Abcve)
Ci 9.h6E-02 5 13E-03 Xenen-133 Ci 7.6LE-03
TABLE h PALISADES :."* CLEAR PCWER P!.Afr" EFFLUE:iT AND WASTE DISPOSAL SDCAN?iUAL REPORT (1979)
SOLID WASTE AND IPPADIATED WEL SHIRCITS A.
20 LID WASTE SEIFFD OFFSITE POR BURIAL OR DISPOSAL (ICT IRPADIATD WIL)
SECOND 1.
Type of Waste v.I5}g 3
Units a.
Spent resins, filter sludges, m5 1.llE+01 evaporater botte=s, etc.
Ci 5.72E+01 b.
Dry co=;ressible vaste, contaminated m3 3.L5E+02 equipment, etc.
C1 1.29E+01 3
5.coE_ol c.
Irradiated co=ponents, control reds, m
etc.
C1 2.71E+02 d.
Other (describe) m3 Ci 2.*
Solid Waste Disposition Destination Number of Shiements Mode of Trans:crtation License Number 11 Truck Chem-Nuclear Systems, Inc.
Barnwell, 30 lho-13536-01 2
Truck Nuclear Engineering Cc=pany Richland, WA
'C-IOl9 2 3.
IRPADIATD FUEL SEI?MENTS (DISIOSITION)
Number of Shipments Mode of Transportation Destination Ncne
.