ML19294B698

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-338/79-52 & 50-339/79-58 on 791203-21 & Notice of Violation
ML19294B698
Person / Time
Site: North Anna  
Issue date: 01/16/1980
From: Oreiily J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Proffitt W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
Shared Package
ML19294B691 List:
References
NUDOCS 8003050344
Download: ML19294B698 (2)


See also: IR 05000338/1979052

Text

.

/

'o

UNITED STATES

8

^g

NUCLEAR REGULATORY COMMISSION

o

$'

E

REGION ll

'#

o

101 MARIETTA sT., N.W., SUITE 3100

  • V

ATLANTA, GEORGIA 30303

o

.....

JAN 161979

In Reply Refer To:

RII:MSK

50-338/79-52

50-339/79-58

Virginia Electric and Power Company

ATTN:

W. L. Proffitt

Senior Vice President, Power

P. O. Box 26666

Richmond, VA 23261

Gentlemen:

This refers to the inspection conducted by M. S. Kidd of this office on

December 3-21, 1979, of activities authorized by NRC License No. NPF-4 and

Construction Permit No. CPPR-78 for the North Anna Power Station facility, and

to the discussion of our findings held with W. R. Cartwright at the conclusion

of the inspection.

Areas examined during the inspection and our findings are discussed in the

enclosed inspection report. Within these areas, the inspection consisted of

selective examinations of procedures and representative records, interviews with

personnel, and observations by the inspector.

During the inspection, it was found that certain activities under your license

appear to be in noncompliance with NRC requirements. This item and references

to pertinent requirements are listed in the Notice of Violation enclosed here-

with as Appendix A.

This notice is sent to you pursuant to the provisions of

Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal

Regulations. Section 2.201 requires you to submit to this office, within 20

days of your receipt of this notice, a written statement or explanation in reply

including:

(1) corrective steps which have been taken by you and the results

achieved; (2) corrective steps which will be taken to avoid further noncom-

pliance; and (3) the date when full compliance will be achieved.

In addition to the need for corrective action regarding these specific items of

noncompliance, we are concerned about the implementation of your management

control systems that permitted their occurrence.

Consequently, in your reply,

you should describe in particular those actions taken or planned to improve the

effectiveness of your management control systems.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,

Title 10, Code of Federal Regulations, a copy of this letter and the enclosed

inspection report will be placed in the NRC's Public Document Room.

If this

report contains any information that you (or your contractor) believe to be

proprietary, it is necessary that you make a written application within 20 days

to this office to withhold such information from public disclosure. Any such

application must include a full statement of the reasons on the basis of which

it is claimed that the information is proprietary, and should be prepared so

.

.

4

JAN 161979

Virginia Electric and Power

-2-

Company

.

that proprietary information identified in the application is contained in a

separate part of the document.

If we do not hear from you in this regard within

the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this letter, we will be glad ta discuss

them with you.

Sincerely,

we

3..

_

N

, 1

James P. O'Reilly 0

Director

Enclosures:

1.

Appendix A, Notice of Violation

2.

Inspection Report Nos. 50-338/79-52

and 50-339/79-58

cc w/ encl:

W. R. Cartwright, Station Manager

Box 402

Mineral, VA 23117

.

P. G. Perry

Senior Resident Engineer

P. O. Box 38

Mineral, VA 23117

- _ . .