Notice of Violation from Insp on 790901-30
ML19291C414
Person / Time
Site: Peach Bottom  
Issue date: 11/09/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19291C400 List:
References
50-277-79-23, 50-278-79-25, NUDOCS 8001240372
Download: ML19291C414 (2)


Text

.

APPENDIX A

' NOTICE ~OF' VIOLATION Philadelphia Electric Company Docket Nos. 50-277 50-278 Based on the results of an NRC inspection conducted on September 1 -

September 30, 1979, it appears that one of your activities was not conducted in full compliance with conditions of your NRC Facility License Nos. DPR-44 and DPR-56 as indicated below.

This item is an infraction.

Technical Specification 6.1.1,

" Radiation Protection Program", requires that procedures for personnel radiation protection shall be prepared consistent with requirements of 10CFR Part 20 and shall be approved, maintained, and adhered to for all operations involving personnel exposure.

1.

Health Physics Procedure HP0/CO-4, " Radiation Work Permits",

Revision 13, dated March 20, 1979,Section III states in part....

"The responsibility for following the requirements of the RWP will be accepted by each individual when he signs in on the RWP".

.... RWP 2-94-0555 dated September 14, 1979, issued for decontam-ination of equipment and-system components in the Unit 2 116' foot elevation chemical decontamination area states that taped openings are required under anti-contamination requirements.

Contrary to the above requirements, on September 17, 1979, two individuals who had signed in on RWP 2-94-0555 were observed working in the chemical decontamination area, a contaminated area, with untaped open coveralls and untaped gloves.

2.

Health Physics Procedure HP0/CO-4, " Radiation Work Permits",

Revision 13, dated March 20, 1979, requires in Section VI that each person shall provide the following data on the Radiation Work Permit (RWP) upon leaving:

a) Time out b) Dosimeter reading c) Differential dosimeter reading Contrary to the above requirement, between September 18 and 20, 1979, seven individuals who had signed in on RWP 3-94-0423, dated August 2, 1979 for Unit 3 refueling floor general work areas, failed to provide the required information upon leaving.

On September 19 and 20, 1979, four individuals signed in on RWP 3-01-0492, dated September 15, 1979 for Unit 3 MSIV room valve repair, general maintenance, and inspection, without providing the required information upon leaving.

17952Bli 8001240 372_

Appendix A 2

3.

Health Physics Procedure HP0/CO-4, " Radiation Work Permits",

Revision 13, dated March 20, 1979, requires in part in Section VI, that all personnel who desire to enter the area covered by the RWP shall read and be familiar with the data and instructions on the RWP, sign their own name, and provide name, date, time in, dosimeter reading.....

Contrary to the above requirement, on September 24-25, two individuals were working under RWP 2-64-0563 in a Unit 2 reactor building hot tool repair cage who had not signed in or provided appropriate data on the RWP.

1795 N9

)