ML19291C199

From kanterella
Jump to navigation Jump to search

Supplemental Info to RO 80-3.One Tube Defective on Steam Generator Hot Leg 21.One Tube Defective & Ten Tubes Degraded on Cold Leg 21.Hot Leg 22 to Be Inspected.Four Tubes Defective & 42 Degraded on Cold Leg 22.Cause Unknown
ML19291C199
Person / Time
Site: Prairie Island 
Issue date: 01/15/1980
From: Tierney F
NORTHERN STATES POWER CO.
To:
References
TAC-12657, NUDOCS 8001230114
Download: ML19291C199 (1)


Text

-

..^r-- m

-,.(

hj h

TC- + 3.-

--..a iSW~~

~

NORTHERN STATES POWER COMPANY PRAIRIE ISLAND NL'CLEAll GENER.iTING PL. INT RM 92 Welch,. TIN 55089 January 15, 1980 Mr. James G. Keppler, Director Region III Office of Inspection and Enforcement US Nuclear Regulator / Co m ission 799 Roosevelt Road Glen Ellyn, IL 60137 Atteativa.

R. 7. Warnich.

Supple = ental Information on Reportable Occurrence No. n-3 Since initial written notification of tais event on January 10, Is3C, cdditional eddy current examinations have been done.

Results to date sc.cw:

50. 21 Stean.mnerator Hot Leg 499 tuces inspected

.-u ti. /

1 tt. e c o und u, e f e c tave (repcrte; ca eanuar)

No. 21 Stea= Generator Cold Leg 642 tu es inspected 1 found defective 10 tubes fauna degraded No. 22 Steam Generator Hot Leg (to be inspected)

No. 22 Steam Generator Cold Leg 1079 tubes inspected

-+ found defective 4214 found degraded The vast majority of degraded tubes are being found at or near :he ;riphery with the indications appearing at the first or sc:end tu:: su;,crts.

Sc theory for the degradation has yet been advarced. Plans are being made ;c - n c '.

2 degraded tube for further exanination.

Sincerely,

/7 ff j&Mlf

?.-

F. P. Tierney, Jr.

Plant Manager

[}j.}h[

Prairie Island Nuclear Plant FFT/ 3h

<0 }

_. O.

.u.a.. e,

)

ss D ir;teto r, MIPC (2) f c/o Distribution Services 3 ranch, 2 C,.CM C. D. Feierabend

/ p 8001230119-c a m

D D

D

~ h 3R

~

_