Text
'*
Page 2 - Certificate No. 9028 - Revision No. 3 - Docket No. 71-9028 5.
(b)
Contents (1) Type and form of material Cobalt-60 or Iridium-192 as sealed sources which meet the requirements of special form as defined in 571.4(o) of 10 CFR Part 71.
(2) Maximum quantity of material per package 11 Curies of Cobalt-60; or 240 Curies of Iridium-192 6.
The source shall be secured in the shielded positio1 of the packaging by the shipping plug, source assembly, and locking device.
The shipping plug, source assembly used must be fabricated of materials capable of resistinq a 1475 F fire environment for one-half hour and maintaining their positioning function.
The ball stop of the source assembly must engage the locking device. The flexible cable of the source assembly and shipping plug must be of sufficient length and diameter to provide positive positioning of the source in the shielded position.
7.
The name plates shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.
8.
The package authorized by this certificate is hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.
9.
Expiration date:
December 31, 1984.
REFERENCES Technical Operations, Inc. application dated September 27, 1979.
Supplement dated: November 9, 1979.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION Ehw Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:
UEC Ii ;g g 8" #
1791 062