Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in IE Insp of License 42-02084-02 on 791208.Requests Addl Info Re Shielding in Storage Area
ML19291A755
Person / Time
Issue date: 02/13/1979
From: Brown G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
TUBOSCOPE, INC. (FORMERLY AMF TUBOSCOPE, INC. - SUBS.
Shared Package
ML19291A747 List:
References
790312, NUDOCS 7905240818
Download: ML19291A755 (1)


Text

..

en nicoq UNITE D STAT ES

  • g' o

NUCLEAR REGULATORY COMMISSION S

g p

rg REGION IV

.g 611 RYAN PLAZA DRIVE, SUITE 1000

  • Y AR LINGTON, TEX AS 76011 o

\\q' ' e..r

,/

March 12,1979 License No. 42-02084-02 AMF Tuboscope, Inc.

ATTN: Mr. B. E. Thomas Senior Vice President 2919 Holmes Road Houston, Texas 77001 Gentlemen:

Thank you for your letters of January 19 and February 13, 1979, in response to our letters of December 22, 1978, and February 5,1979.

As a result of our review of your February 13, 1979 letter, and discussion with you by telephone on March 7,1979, we find that additional information is needed.

Specifically, we need to know that the shielding installed in the storage area is adequate to assure that if an individual were continuously present in the unrestricted area outside the building but adjacent to the storage area for seven consecutive days that he would receive 100 millirems or less.

You should, therefore, submit this information within 10 days of your receipt of this letter so that we can continue our review of this matter.

Should you have any questions concerning this letter, please let me know.

Sincerely, Ll&d -u

/ Glen

. B,rown, Chief Fuel Facility and Material Safety Branch 79052407If CERTIFIED MAIL - RETURN RECEIPT REQUESTED