Docket No.
50-445/79-28 50-446/79-27 APPENDIX A NOTICE OF VIOLATION Based on the results of the NRC inspection conducted during the r:riod of December 4-7 and 10-13, 1979, it appears that certain of your activities were not conducted in full compliance with the conditions of your NRC Construction Permit No. CPPR 126 as indicated below:
Failure to Provide Appropriate Instructions for Installation of Class IE Equipment 10 CFR 50, Appendix B, Criterion V requires appropriate documented instruc-tions or procedures to accomplish activities affecting quality.
IEEE Standard 336, 1971, requires in paragraph 2.3 that installation of Class IE equipment be performed in accordance with the latest information and shall include as appropriate, approved construction drawings, installation specifications, manufacture's instructions, etc.
Contrary to the above:
1.
On December 11, 1979, the IE inspector reviewed Construction Operational Traveler No. EE 79-131-02AB for the instellation of the Unit 1 Hot Shut-down Panel and inspected the actual completed panel installation. The IE inspector observed that the floor supports for the air conditioning unit for this panel were missing.
2.
Operational Traveler EE 79-131-02AB did not reference the Gibbs & Hill Construction Drawing (S1-608) or the Reliance Instruction M-LV01701F that indicated the support requirement. The steel and hardware for these supports were supplied with the panel. The IE inspector found the steel and hardware laying inside the walk-in panel.
This is an infraction.