Forwards IE Bulletin 80-04, Analysis of PWR Main Steam Line Break W/Continued Feedwater Addition. No Written Response Required
ML19290F062
Person / Time
Site: Farley 
Issue date: 02/08/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Clayton F
ALABAMA POWER CO.
References
NUDOCS 8003180025
Download: ML19290F062 (2)


Text

'

pa mac oq'o UT.1TED STATES

! *g, T NUCLE AR REGUL ATORY CO*.'.M!SSION g

i

4 4.;,%., f e

RE GION li o, ri. 2:,., J' 101 M ARIETT A ST., N.W., SUITE 3100 f*(/ 9 e

AT LANT A, G E oRGI A 30303 Og

....+

FEB S 1983 In Reply Refer To:

RII:JP0 r[50-364 Alabama Power Company y

Attn:

F. L. Clayton Senior Vice President Post Office Box 2641 Birmingham, AL 35291 Gentlemen:

The enclosed IE Bulletin No. 80-04, is forwarded to you for inforcation.

No written response is required.

If you desire additional information regard-ing this matter, please contact this office.

Sincerely, p James P. O Re 11y Director s

Enclosures:

1.

IE Bulletin No. 80-04 2.

Most Recently Issued

?

IE Bulletins e

i

~

8003180o2 5

t iU" b d30 Alabama Power Company.

cc w/ enc 1:

A. R. Barton Executive Vice President Post Office Box 2641 Birmingham, Alab:ma 35291 H. O. Thrash Manager, Nuclear Generation Post Office Box 2641 Birmingham, Alabama 35291 C. Biddinger, Jr.

.ianager-Carporate Quality Assurance Post Office Box 2641 Birmingham, Alabama 35291 G. Hairston, III ant Manager rawer 470 thford, Alabama 36312

~

R. E. Hollands, Jr.

QA Supervisor Post Office Box U Ashford, Alabama 36312 e

d O

I i

e n.-- - -~

_ - - -... ~ - - -

I UNITED STATES SSINS No.:

6820 NUCLEAR REGULATORY COMMISSIC.

Accessions No..

OFFICE OF INSPECTION AND ENFORCEMENT 7910250504 WASHINGTON, D.C.

20555 February 8,1980 IE Bulletin No. 80-04 ANALYSIS OF A PWR MAIN STEAM LINE BREAN WITH CONTINUED FEEDWATER ADDITION Description of Circumstances:

Virginia Electric and Power Co. submitted a report to the Nuclear Regulatory Commission dated September 7, 1979 that identified a deficiency in the original analysis of containment pressurization as a result of reanalysis of steam line break for North Anna Power Station, Units 3 and 4.

Stone and Webster Engineering Corporation performed a reanalysis of containment pressure following a main steam line break and determined that, if the auxiliary feedwater system continued to supply feedwater at runout conditions to the steam generator that had experienced the steam line break, containment design pressure would be exceeded in approximately 10 minutes. The long term blowdown of the water supplied under runout conditions by the auxiliary feedwater system had not been considered in the earlier analysis.

On October 1,1979, the foregoing information was provided to all holders of operating licenses and construction eermits in IE Information Notice No. 79-24.

The Palisades facility did an accident.nalysis review pursuant to the information in the notice and discovered that with offsite power available, the condensate pumps would feed the affec ed generator at an excessive rate.

This excessive feed was not considered in th- -r:!ysis for the steam line break accident.

On January 30, 1980, Maine Yankee Atomic Power Company informed the NRC of an error in the main steam line break analysis for the Maine Yankee plant.

During a review of the main steam line break analysis, for zero or low power at the end of core life, the licensee identified an incorrect postulation that the startup feedwater control valves would remain positioned "as is" during the transient.

In reality, the startup feedwater control valves will ramp to 80% full open due to an override signal resulting from the low steam generator pressure reactor trip signal. Reanalysis of the event shews the opening of the startup valve and associated high feedwater addition to the affected steam generator would cause a rapid reactor cooldown and resultant return-to power, a condition outside the plant design basis, Actions to be Taken by the Licensee:

For all pressurized water power react reactors listed in Enclosure 1:

DUPLICATE DOCUMENT 1.

Review the containment pressure 1 Potential for containment overpre Entire docannent previously entered into system under:

ANO of pag,es:

No.