W 8(ggnntav o
o UNITED STATES g
g NUCLEAR REGULATORY COMMISSION 3
j REGION 1 631 PARK AVENUE
/
KING OF PRUSSIA, PENNSYLVANIA 19406 February 29, 1980 Docket No. 50-293 Boston Edison Company M/C Nuclear ATTN:
Mr. G. Carl Andognini, Manager Nuclear Operations Department 800 Boylston Street Boston, Massachusetts 02199 Gentlemen:
Enclosed is supplemental information to IE Bulletin No. 79-018.
This information is presented in the form of generic questions and answers which will assist you in responding to the actions required of IE Bulletin No. 79-018 issued on January 14, 1980. Should you have any questions regarding this supplemental information, please contact this office.
Sincerely,
' $ Y.
- 4. /
e H. Grier 1 rector
Enclosures:
1.
Supplemental Information to IE Bulletin No. 79-018 w/ Attachments 2.
List of Recently Issued IE Bulletins CONTACT:
S. D. Ebneter (215-337-5296) cc w/encls:
P. J. McGuire, Pilgrim Station Manager 9003140 353
ENCLOSURE 1 UNITED STATES SSINS No: 6820 NUCLEAR REGULATORY COMMISSION Accessions No:
OFFICE OF INSPECTION AND ENFORCEMENT 7912190696 WASHINGTON, D.C.
20555 IE Bulletin No. 79-018 Supplemental Information Date:
February 29, 1980 Page 1 of 1 ENVIRONMENTAL 0UALIFICATION OF CLASS IE EQUIPMENT Enclosed are the generic questions and answers which resulted from NRC Task Group / Licensee " workshop" meetings held recently in NRC Regional Offices regarding IE Bulletin No. 79-018.
This information is intended to further the understanding of the qualification review process and reporting requirements of the Bulletin.
The further intent of this information is to assist the licensees in providing a method of approach acceptable to the assigned NRC Task Review Group in determining adequacy of the environmental qualification of Class IE Electrical Equipment installed at their respective facilities.
It should be recognized that the review of the licensee's responses may generate additional need for guidance of finalized resolution of the environmental qualification issue.
Attachient:
Generic Questions and Answers to IE Bulletin No. 79-018 ODUPLI Entire document previously entered into system under:
[d [h d, b. k h ANO b
N o.
of pages: