Text

?

NUCLE AR ENERGY BUSINESS GROUP

  • GENE R AL ELECTRIC COMP ANY SAN JOSE, CALIFORNI A 95125 GENER AL h ELECTRIC APPLICABLE TO:

e -240R1 PueucATiON No RMM bd MDmM T. l. E. NO.

77NED355 SHEET LOCA Analysis for Peach 5

TITLE No.

Botton APS Unit 2 January 1980 DATE NO TE. Correct all copies of the applicable ISSUE DATE DeCe~ hey 10II publicatiors as specified below.

F N ES INSTRUCTIONS (COR RECTIONS AND ADDITIONS) p gAo ApH L NE) 1.

Page 4-11/4-12 Replace with revised page 4-11.

2.

Insert new page 4-12.

,.a y gG) if-l'

'sf ',.

(\\\\ O i ! M'.E d i' PAGE 8003100 2,24

e NEDO-24031 Tabic 4-3 e MAPLHGR VERSUS AVERAGE PLA';AR DTOSURE Plant:

PB-2 Fuel Type:

LTA260 Average Planar Exposure MAPLHGR PCT 0xidation (Mwd /t)

(kW/ft)

(*F)

Fraction 200 11.4 1829 0.007 1,000 11.5 1839 0.003 5,000 12.1 1913 0.010 10,000 12.2 1929 0.011 15,000 12.3 1958 0.012 20,000 12.1 1961 0.012 25,000 11.7 1911 0.C10 30,000 11.3 1832 0.009 35,000 10.3 1752 0.006 40,000 9.7 167S 0.004 45,000 9.1 1603 0.003 50,000 8.5 1567 0.002 Table 4-3f MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE Fuel Type:

SDRB284 Local Expcsure MAPLEGR PCT 0xidation CCd / t)

(k'.i/ f t)

(*F)

Fraction 200 11.3 135S 0.009 1,000 11.3 1362 0.009 5,000 11.3 1926 0.011 10,000 12.0 1937 0.011 15,000 12.0 1947 0.012 20,000 11.6 1910 0.010 25,000 10.9 19'9 9. # #, S 30,000 10.2 1751 0.006 4-11

.(

NED0-24081 Table 4-32 MAPLHGR VERSUS AVERAGE PLANAR EXP0ftRE Fuel Type:

PSDRB234H

  • l Average Planar Exposure MAPLHGR PCT 0xidaticn (mwd /t)

(kW/ft)

(*F)

Fraction 200 11.2 1861 0.008 1,000 11.2 1865 0.008 5,000 11.7 1993 0.010 10,000 12.0 1938 0.011 15,000 12.0 1933 0.011 20,000 11.5 1907 0.011 25.000 10.8 1823 0.007 30,000 10.1 1744 0.005

  • Applicable to 80, 100, and 120 mil channels.

Fuel Type:

PSDR3285 200 11.0 1326 0.008 1,000 11.1 1836 0.008 5,000 11.9 1924 0.011 10,000 12.2 1948 0.012 15,000 12.1 1943 0.011 20,000 11.7 1903 0.010 25,000 11.0 181S 0.007 30,000 10.3 1740 0.005 4-12