i NUCLE AR ENERGY BUSINEM GROUP e GENERAL ELECTRIC COMPANY SAN JOSE, CALIFORNI A 95125 GENER AL h ELECTRIC APPLICABLE TO:

PUBLICATION NO

" F D'- 2 ' f' 81 ERRATA And ADDENDA T. I. E. NO.

SHEET LOCA Analysis for Peach TITLE 4

Botton APS Unit 2 g

,q79 NO TE: Correct allcopies of the applicable December 1977 publication as specified below.

issue DATE REFERENCES INST RUCTIONS ITE M (SECTION, PAGE PA R AG R APH. LINE)

(COR RECTIONS AND ADDITIONS) 1.

Page 4-10 Replace with revised page 4-10.

2.

Page 4-11/4-12 Replace with re-ised page 4-11/4-12.

D I

PAGE I

8003100'219

NEDO-24081 Table 4-3c MAPLl!GR VERSUS AVERAGE PLANAR EXPOSURE Plant:

PB-2 Fuel Type:

8D274L Average Planar Exposure MAPLilGR PCT 0xidation (Mwd /t)

(kW/ft)

(*F)

Fraction 200 11.2 1758 0.006 1,000 11.3 1765 0.006 5,000 11.9 1845 0.008 10,000 12.1 1862 0.008 15,000 12.2 1890 0.009 20,000 12.1 1891 0.009 25,000 11.6 1853 0.007 30,000 10.9 1773 0.005 4-9

NEDO-24081 Table 4-3d MAPLIIGR VERSUS AVERAGE PLANAR EXPOSURE Plant:

PB-2 Fuel Type:

8D274H*

Average Planar Exposure MAP LilGR PCT 0xidation (Hwd/t)

(kW/ft)

('F)

Fraction 200 11.1 1755 0.006 1,000 11.2 1755 0.006 5,000 11.7 1830 0.007 10,000 12.1 1869 0.008 15,000 12.2 1894 0.009 20,000 12.0 1892 0.009 25,000 11.5 1848 0.007 30,000 10.9 1778 0.006 35,000 9.9 1664 0.003 40,000 9.3 1591 0.003

  • Applicable to 80, 100 and 120 mil channela.

4-10

J NEDO-24081 Table 4-3 e MAPLilGR VERSUS AVERAGE PLANAR EXPOSURE Plant:

PB-2 Fuel Type:

LTA260 Average Planar Exposure MAPLilGR PCT 0xidation (Mwd /t)

(kW/ft)

(*F)

Fraction 200 11.4 1829 0.007 1,000 11.5 1839 0.008 5,000 12.1 1913 0.010 10,000 12.2 1929 0.011 15,000 12.3 1958 0.012 20,000 12.1 1961 0.012 25,000 11.7 1911 0.010 30,000 11.3 1882 0.00) 35,000 10.3 1752 0.006 40,000 9.7 1678 0.004 4-11/4-12