For,, A E C.7 '
U.S. ATOMIC ENERGY COMVf SSION Form opproved Budget Bureau No.
in njn wash.ngton, D C. 20545 3 8-R0007.
.. 3 )(Sg/n 1M'l 7d*y175 APPLICATION FOR LICENSE TO EXPORT d.nlt,
- BYPRODUCT, SOURCE, OR SPECI AL NUCLEAR MATERIAL 5-$93 i
E' THIS DOCUMENT CONTAINS S a,,,,,t 7,,v,cate a EC 29 P POOR QUAUTY PAGES
%\\c 17-CoS Carefulls Rmid Instruction s on ILu k 1 O A TE OF A P F.. C A TION 2 A PPLIC AN T'S R EF rRENC E NO 3 COUN TRY O' ULTIM ATE D ES TIN ATION December 29, 1977 UUE M I/EU/15377-430/01 Sweden s
4 N AME OF APr.lCANT 5 ULTIM ATE CONSIGNEE IN FOREIGN COUNTRY N '"" ""'"dd' Transnu : lear, Inc.
Studsvik AB S T R E E T A D t' ESS 5205 '. 2sburg Pike Atomenergi Sweden CITY. Sv -
. ANO zip CODE Fack, S-61101 Mykoping 1 Fall, diurch, Virginia 22041 Sweden 6 IN TEF'MEOl A TE CON SIGN EE IN FOR EIGN COU NTR Y (Grre name 7 IF PURCH AS ER IN FOR EIGN COU N TRY 15 OTH ER THAN mad a./decs s I/ Sa*w a s ultumrL'e mnstgnee, state "Sa**e. ")
ULTIM A TE CON $lGN EE, GIVE N A ME AN D ADO RESS ut same state "Sec."> OTHER INTERMEDI ATE CONSIGNE.:
Transnuklear GmbH 645 Hanau 645 Hanau, Postfach 110030 Germani Federal rapublic of Germany and CERCA, 2104 Romans-sur-Isere, France W Ifgang-bei-Industriegelande, Hessen, W./
S (a) QU a N T1TY TO B E Sr*1PPE O (b) COMM OO ST Y DESCR t PTION Hnclude che mcal a'id pb> sscal l nrm; for special riuclear reaternal and (See t ristr'sctrons on bacU byproduct matertal also Tectf> tsotop tc conter:t; tl In a devtce, identify the det sce, mantd.tcturer, e:d model number.)
28.707 KgU308 Uranium in the form of uraniur oxide enriched to a maximurc 24.200 KgU 22.579 KgU235 3 pgreent U235. This material will be supplied and packaged by United Nuclear Corp., Woodriver Junction, Rhode Island. Ship-ment to take place as soon as license is issued.
(cf SH a cPIN G A n o P A C KIN G POOC E O U R E S ! Reg'stred for ne tal -nclear matertrs. See nr:strictions on bars >
I.A.E.A.
Certificate of Competent Authority 4909 in accordance with 10 CFR Part 71.
9 ENO USE Os C MOOITICL COVERED EV TH l1 A POLIC A TION. (Descr be /u s. Mat:nw uhat 9 r.1 Fe prouared or mam/actr. red al at sert it.'
u sH Le remiered. c r the nat:.re of the research that uld he p er! Ped.) t See unstr'.rtwn s on kark for 17ecta: nci ect r-af rrial. )
Will be used for the manufacture of fuel elements for the R-2 Reacter in Sweden.
(See attached End Use Statement) to The applicant. and any official executine this certificate on behalf of the applicant named in item 4. certify that this arplication is prepared in conformity with Title 10. Code of Irederal Heplations. Parts 30 and 46 (if for bvproduct rnaterial) or Part 40 (if tor source materialt or Part ~0 (if for special nuclear matertall-and Part 'l (for transrort of radiaactive naterial. if applienies and enat all in formation contained herein. including any supplements attached hereto, is true and carrect to the best of thei-knowledge and belief This material is privately owned.
Transnuclear, Inc.
Please issue license for a period of
( Art'Itcant named in lic t <>
one year.
Vicki Mats _on
/j C
ily:
g Traffic Ccordinator JLt:u-7f#w 2);; ; '"'" "" "'* **"" ' "' "" * "'
- 7 or w 7904110CO3 0,w - p
- - $cetion 1 *,01. A e o f one 25 19 42 6 7 ' ent 747 mnk es it n criminni ofica w ta mk e o ~ill full y inl e e s to k-
se C
ON A
b(.r r n - --] ffj$M
%g db Un&
A'B ATOMENERGt SWEDEN Cate our reference 1977-12-07
- - - -., -) re ference Ces't with by Your date
- C ' Wo E Blomberg U77 C3C 29
.C.',
/, j!
To whom i: may concern
.r--,s...,,-.
.u "1.'.i'l $7GID3 End Use Statement The undersigners certify that the following material, i.e.
28.707 kgs of U 0 -Powder, equivalent to 24.200 kgs of 33 uranium having a U-233 assay of ')3.3 per cent and containing 22.579 kys of U-235 and will be used by us for manufact.uring of fuel elements for the R2-reactor, Studsvik, ';ykUping, Sweden and shall be purchased by us from SUKEM CmbH, D6450 llanau, Federal Republic of Germany. NUKEM CmbH shall perform the conversion work for us. Manufacturing of the fuel elements for use in the reactor R2 at Studsvik shall be performed by
.NUKEM GmbH, D-6450 HANAU 11, Postfach 110080, Federal Republic of Germany and CERCA, 26104 Romans-sur-Issre, France.
's'e authorize Transnuclear Inc., Falls Church, 'lirginia to apply for the export license.
Studsvik, December 7, 1977 AKTIEBOL\\GET ATOMENERGI Section for Materials Research Reactor R2 y,1 ' _..
K Saltvedt D**]D
]D
' T l k
.a a n o N N
..N0%
L'
i. i.
..an/,t.3/ l % -e
.,^...
C=...'s'*'.'.'6'.
=, C *.. ".c ~'.....
c,,
^
..v...'_,~.~.~2r,'. _., _. ' _,.. ',
(;.
a;,,,,~,,,,<'e
,.-g~,~
.n....
r.,
s.
,.7., t.,
.._m
.t.
. : ;,._,. t.,,
,_m
..p-.
N vember 15, 1977 Date Reactor R2, A3 Atomenergi, Studsvik, S-61101 NYKUPING 1, Sweden 1.
,.,e. e o f r,aci lity:
- -- - ~
- 2. Quantity of Uranium Requested (Fgs):
39 93
- 3. Enrichment in the Icotope U-235 (%):
17 kgs U; Toll enrier.ent contract wita : usem/ t.urno,jer.,
- 4. Sale or 'I'oll D'.riching: 22 kes U in form of U30S; Purchase contr'act with Nukea GmbH
- 5. Current Ccre Leading (Fgs or U-235):
8,9 1 o,4 U235
- 6. Current Power Level (L~dth):
50>!d
- 7. Criticality and Full cterating Power Dates ar.d power nating (ir reque:: 13y3173 new facility):
-~~
- 6. 'ic.mc of Convertar and Fabricator of Fuel: 1) Nukem GmbH, D-6450 HANAU 11, Postfach 110080, West Ce rcan'.
- 2) Cerca, 2610' Romans-sur-Issre, France
- 9. 3rcakdowr of Fuel Invertory (:'gs of U-235):
- a. A cunt of U-235 in Fabrication outside USA Including 3 crap A1,. s.w,., e o. Nukem 11 kgs U235-Enrichment about 9 0l', Cerca 16.25 U235-Enrichment 93'
.m
- b. k-cunt cf U-235 in storage in Cce:leted, Unirradiatee :suel glements:
12.86 x;;s U235
- c. Accu'.t of U-235 in Cere:
8,9 1 0,4 kgs U235
- d. Amcunt of U-235 in Scent Fuel Storage within Sweden (R2 plant) and savannah River Plant (Chemical Reprocessing Plant) and the Reprocessing Schedule for Such ifaterial.
Se enclosed "CO:9LESiENT TO CHECKLIST"
- e. A= cunt of U-235 Lost and/or Consu :ed During operation of Above Facilit.v:
16,9 kgs U235/ year
- 1. Standard fuel eietents
.D u g U.0 5
- f. Arount of U-235 ter Pael Element: 2. Control red fuel eierents 193 g U235
- g. Aver?.ge Core Life:
13 days
- h. Averare '.ead Time fer Cenvercien and Pac 1 Fabricatier if Cenvercicn a-d 7... r.-
s
.. -,,. 9 e ".* 7
.O 8
v..a COMPLE.'!ENT TO Tl!C CllECKLIST The quantity of 39 kgs uranium in our request;js for nanufacturing of 110 standard fuel elements and 20 control rod fuel sections (1 year's need) for operating the R2 reactor. About 15", of the uranium is a surplus quantity for scrap etc for the manuf acturers, Suken and Cerca.
Operation schedule The R2 reactor is calculated to operate on 50 MW 16 cycles / year or in average 6430 hours0.0744 days <br />1.786 hours <br />0.0106 weeks <br />0.00245 months <br /> / year.
Core loading for each 18-days cycle For each loading we use 44 standard eler.ents (6-7 new elenents - 250 g U235 each and and 38-37 partly burned) and 6 control red fuel elements (0-1 new 5 partly burned).
Total weight of the core for each cycle S,9 1 0,4 ag of U235. Average operation pcwer 50 "W.
Burn-up With existing experiment loading we estimate an averazu burn up of 57 : 2 percent, calculated of U235.
CHECKLIST 9.d All spent fuel will be reprocessed at Department of Energy's Reprocessing Plant at Savannah River.
Contract EY-76-C-09-1018.
All fissile material after processing will be used "as feed" in coming short-term, fixed commitment contracts.
1.
Savannah River Plant; Reprocessed during-1977: 9.6 k;s U235 2.
Spent fuel, waiting for transpert to SRP:
7.12 Reprocessed at SRP Jan-Feb 1978 3.
Partly spent fuel, storage at Studsvik 12,4 4
Reprocessing quantities / year about 13,2
"