Forwards IE Insp Rept 70-1308/79-02 on 790228,0301-02 & 07. No Noncompliance Noted
ML19282D183
Person / Time
Site: 07001308
Issue date: 03/26/1979
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Zahn L
GENERAL ELECTRIC CO.
Shared Package
ML19282D184 List:
References
NUDOCS 7905230437
Download: ML19282D183 (2)


Text

'

PDR j/

4 UNITED STATES NUCLEAR REGULATORY COMMISSION

,. g g

j,l f,I j

REGloN W

  • gy,

f 799 RooSE VELT Ro AD

. *. j GLEN ELLYN ILU NolS 60137 Mt 211979 Docket No. 70-1308 General Electric Company ATTN:

Mr. L. L. Zahn, Jr.

Manager, Spent Fuel Services Operation 175 Curtner Avenue San Jose, CA 95125 Gentlemen:

This refers to the inspection conducted by Mr. W.

L. Axelson of this office on February 28, March 1, 2 and 7, 1979, of activities at Morris Operation authorized by NRC Special Nuclear Material License No. SNM-1265 and to the discussion of our findings with Mr. E. Voiland and others of your staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined during the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and interviews with personnel.

No items of noncompliance with NRC requirements were identified during the course of this inspection. However, during this inspec-tien, a matter was identified which needs management attention.

This is discussed in Paragraph 8 of the enclosed inspection report.

Please advise us in writing within thirty days concerning your intended action to resolve this matter, including completion date.

Based on discussions with Mr. E. Voiland and others of your staf f, we understand that the new Radiological Emergency Plan (NEDE-21894) will be fully implemented on or before April 15, 1979.

As you are aware, NRC's Office of Nuclear Material and Safeguards approved this plan and stated such in a letter dated February 5, 1979, to Mr. D. Dawson of your staff.

In accordance with Section 2.790 of the NRC's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter, the enclosures, and your response to this letter will be placed in the NRC's Public Document Room, except as follows.

If the enclosures contain information that you or your contractors f/

7 9 0 5 23 0 V3-[

General Electric Company MF 251979 believe to be proprietary, you must apply in writing to this of fice, within twenty days of your receipt of this letter, to withhold such information from public disclosure.

The application must include a full statement of the reasons for which the information is considered proprietary, and should be prepared so that proprietary information identified in the application is contained in an enclosure to the application.

k'e will gladly discuss any questions you have concerning this inspection.

Sincerely, A. B. Davis, Chief Fuel Facility and Materials Safety Branch

Enclosure:

IE Inspection Report No. 70-1308/79-02 cc w/ encl:

Mr. E. E. Voiland, Manager Morris Operation hr. D. M. Dawson, Manager Licensing and Transportation Fuel Recovery Operations Central Files Reproduction Unit NRC 20b PDR Local PDR NSIC Mr. Dean Hansell, Office of Assistant Attorney General

..