Forwards IE Insp Repts 50-440/78-15 & 50-441/78-14 on 781128-1201 & Notice of Violation
ML19282B300
Person / Time
Site: Perry  
Issue date: 01/24/1979
From: Heishman R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
CLEVELAND ELECTRIC ILLUMINATING CO.
Shared Package
ML19282B301 List:
References
NUDOCS 7903120537
Download: ML19282B300 (2)


See also: IR 05000440/1978015

Text

.

r-

.

5

,

UNITEo ST ATES

O

4,

NUCLEAR REGULATORY COMMISSION

y .,

..

R EGloN ilt

j

[

.

799 ROOSEVELT ROAD

,

i

f

,

GLE N E LL YN lL LINoIS C0137

~

.%.

.....

.

3T9

-

JnT4 2 4

.

.

Docket No. 50-440

Docket No. 50-441

The Cleveland Electric Illuminating

Company

ATTN:

Mr.

D. R. Davidson

Vice President - Engineering

Post Office Box 5000

Cleveland, OH 44101

Gentlemen:

This refers to the inspection conducted by Messrs. J. E. Konklin,

K. R. Naidu and W. A. Hansen of this office on November 28 -

December 1, 1978, of activities at the Perry Nuclear Plant

Project, Units 1 and 2, authorized b' NRC Construction

Permits No. CPPR-148 and No. CPPR-149 and to the dis-

cussion of our findings with Messrs. G. W. Groscup and

M. R. Edelman and others of your staff at the conclusion

of the inspection.

The enclosed copy of our inspection report identifies areas

examined during the inspection. Within these areas, the

inspection consisted of a selective examination of procedures

and representative records, observations, and interviews with

personnel.

During this inspection, certain of your activities appeared

to be in noccompliance with NRC requirements, as described

in the enclosed Appendix A.

Item No. 1 shown in the Notice

of Violation encl.ised with this letter is a recurrent item.

In your response please give this matter your particular

attention.

This notice is sent to you pursuant to the provisions of

-

Section 2.201 of the NRC's " Rules of Practice," Part 2, Title

10, Code of Federal Regulations.

Section 2.201 requires you

to submit to this office within thirty days of your receipt

of this notice a written statement or explanation in reply,

including for each item of noncompliance: (1) corrective

action taken and the results achieved; (2) corrective, action

to be taken to avoid further noncompliance; and (3) the date

when full compliance will be achieved.

7903ygogzn

e .

,

.

b

#

The Cleveland Electric

-2-

Illuminating Company

,

In accordance with Section 2.790 of the NRC's " Rules of

Practice," Part 2, Title 10, Code of Federal Regulations, a

copy of this letter, the enclosures, and your response to

this letter will be placed in the NRC's Public Document Room,

except as follows.

If the' enclosures contain information

ti.at you or your contractors believe to be proprietary, you

must apply in writing to this office, within twenty days of

your receipt of this letter, to withhold such information

from public disclosure.

The application must include a full

statement of the reason 7 for which the information is con-

sidered proprietary, and should be prepared so that proprietary

information identified in the application is contained in an

enclosure to the application.

We will gladlJ discuss any questions you have concerning this

inspection.

Sincerely,

Q.:;> ]'l. wn l: fo-

[/ . F. Ecishm'an, Chief

R

Reactor Construction and

Engineering Support Branch

Enclosures:

'

'

l.

Appendix A, Notice of

Violation

2.

IE Inspection Rpts No.

50-440/78-15 and No.

50-441/78-14

cc w/encls:

Central Files

Reproduction Unit NRC 20b

PDR

Local PDR

NSIC

TIC

U. Young Park, Power Siting

Commission

Mr. Daniel D. Wilt, Attorney

.-