b UNITED ST ATES j

e'x 4

NUCLEAR REGULATORY COMMISSION j,,l{d5Gf E l

.j WASWNGTON, D. C. 20SES s'l g, v j FEB 6 1979 Docket Nos. 50-369 and 50-370 Mr. William O. Parker, Jr.

Vice President, Steam Production Duke Power Corapany P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Parker:

SUBJECT:

CASK DROP ANALYSIS (McGuire Nuclear Station, Units 1 and 2)

As.a result of our continuing review of your application, we find that we are in need of specific information regarding the spent fuel cask accident analysis. This information is described in the Enclosure.

We request that this information be provided no later than March 2,1979.

Please contact us if you have any questions concerning this matter.

Sincerely, y

n AN W, l5&]

Ro ert L. Baer, Chief Light Water Reactors Branch No. 2 Division of Project Management

Enclosure:

Request for Additional Inforn.ation ccs w/ enclosure:

See page 2 79030601H

Mr. William 0. Parker, Jr.

Vice President, Steam Production FEB C MM Duke Power Company P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 cc:

Mr. W. L. Porter Duke Power Company P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 Mr. R. S. Howard Power Systems Division Westinghouse Electric Corporation P. O. Box 355 Pittsburgh, Pennsylvania 15230 Mr. E. J. Keith EDS Nuclear Incorporated 220 Montgomery Street San Francisco, California 94104 Mr. J. E. Houghtaling NUS Corporation 2536 Countryside Bculevard Clearwater, Florida 33515 Mr. Jesse L. Riley, President The Carolina Environmental Study Group 854 Henley Place Charlotte, North Carolina 28207 J. Michael McGarry, III, Esq.

Debevoise & Liberman 700 Shoreham Building 806 15th Street, N. W.

Washington, D. C.

20005 Shelley Blum, Esq.

418 Law Building 730 East Trade Street Charlotte, North Carolina 28202 s

~

Mr. William 0. Parker, Jr.

.c rn:

w'"

cc: Robert M. Lazo, Esq., Chairman Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Dr. Emmeth A. Luebke Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Dr. Cadet H. Hand, Jr., Director Bodega Marine Lab of California P. O. Box 247 Bodega Bay, California 94923

ENCLOSURE 3g79 Cask Drop Accident Analysis for McGuire 1.

Provide the results of an analysis, including the assumptions,

, analysis, analysis methodology and drawings; that evaluates the consequences of dropping or tipping, or combination of both, of the Oconee fuel cask in the McGuire spent fuel handling building.

The analysis should identify and consider any special equipment to be used in handling the Oconee cask with the McGuire cask handling crane. The analysis should demonstrate that such an event will not cause damage to stored spent fuel or safety related systems or components in the McGuire fuel handling building.

.