e Docket No. 50-334 S'ee I o 1983 DISTRIBUTION Docket filei Mr. J. J. Carey, Vice President NRC PDR
'NSI C Duquesne Light Company Local PDR 1
JTaY U#
Nuclear Division ORB #1 reading Post Office Box 4 DEisenhut ACRS, 10 Shippingport, PA 15077 OELD EJordan
Dear Mr. Carey:
PTam CParrish
SUBJECT:
REPLACEMENT FUEL ASSEMBLY FOR CYCLE 4 - BEAVER VALLEY UNIT I By letter dated September 1,1983, you submitted a revision to your Cycle 4 Reload Safety Evaluation Report. The revision involved the development of a new core loading pattern which was required due to the damage of the K-2 fuel assembly and rod cluster control assembly (RCCA) dur'ng fuel shuffle.
The new core loading pattern merely involves replacement of the fuel assembly at the K-2 position with the fuel assembly from the R-8 position. A new RCCA is also placed in location K-2 with the same neutron absorption proper-ties as the replaced RCCA. A new 3.1% enriched Region 6A fuel assembly will then be placed in the R-8 position.
You indicated that you have evaluated the new ctre loading pattern for Cycle 4 using the methodology described in WCAP-9273, " Westinghouse Reload Safety Evaluation Methodology", and have verified that the results and conclusion _
of the original Cycle 4 RSER, namely core peaking factors, power distributions and reload safety analyses checklist limits, arc still valid.
We agree with this conclusion and, therefore, our previous SER dated August 19, 1983 for the operation of Cycle 4 is still applicable.
This completes our effort on this action.
Steven A. Varga, Chief Operating Reactors Branch #1 Division of Licensing cc: See next page ORB #l:D t
PTa ch 9/I(t 3 Q3 9309270378 830914 DRADOCK05000g
a.
Mr. J. J. Carey Duquesne Light Company cc:
Mr. W. S. Lacey Mr. K. Grada, Superintendent Station Superintendent of Licensing and Compliance Duquesne Light Company Duquesne Light Company Beaver Villey Power Station Nuclear Division Post Office Box 4 Post Office Box 4 Shippingport, Pennsylvania 15077 Shippingport, Penn;ylvania 15077 Charles A. Thomas, Esquire Resident Inspector Thomas and Thomas U. S. Nuclear Regulatory Commission 212 Locust Avenue Post Office Box 298 Box 999 Shippingport, Pennsylvania 15077 Harrisburg, Pennsylvania 17108 Gerald Charnoff, Esquire Regional Administr6 tor - Region I Jay E. Silberg, Esquire U. S. Nuclear Regulatory Commission Shau. Pittman, Potts and Trowbridge 631 Park Avenue 1800 M Street, N.W.
King of Prussia, Pennsylvania 19406 Washington, D.C.
20036 Karin Larter, Esquire Special Assistant Attorney General Bureau of Administrative Enforcement 5th Floor, Executive House Harrisburg, Pennsylvania 17120 Marvin Fein Utility Counsel City of Pittsburgh 313 City-County Building Pittsburgh, Pennsylvania 15219 Mr. John A. Levin Public Utility Commission P.O. Box 3265 Harrisburg, Pennsylvania 17120 Irwin A. Ponowsky, Esquire Office of Consumer Advocate 1425 Strawberry Square Harrisburg, Pennsylvania 17120 0
- 4 e