ML19276G703
| ML19276G703 | |
| Person / Time | |
|---|---|
| Site: | Pilgrim |
| Issue date: | 06/29/1979 |
| From: | Brunner E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Andognini G BOSTON EDISON CO. |
| Shared Package | |
| ML19276G704 | List: |
| References | |
| NUDOCS 7908270117 | |
| Download: ML19276G703 (2) | |
See also: IR 05000293/1979008
Text
..
.
g
,
UNITED STATES
{o
NUCLEAR REGULATORY COMMisslON
- l=
-
o
REGION I
g
j
631 PARK AVENUE
f
41NG OF PRUS$1 A, PENNSYLV ANI A 19406
% ,.* /
%
JUN 2 91979
Docket No. 50-293
Boston Edison Company M/C Nuclear
ATTN: Mr. G. Carl Andognini, Manager
Nuclear Operations Department
800 Boylston Street
Boston, Massachusetts 02199
Gentlemen:
Subject:
Inspection 79-08
This refers to the inspection conducted by Mr. G. Napuda of this office
on May 1-4,1979 at Pilgrim Nuclear Power Station, Unit 1, Plymouth,
Massachusetts and at your corporate offices of activities authorized by
NRC License No. DPR-35 and to the discussio. s of our findings held by
Mr. Napuda with Messrs. S. Rosen, M. Yessallian, C. Vantrease and other
meCars of your staff at the conclusion of the inspection.
Areas examined during this inspection are descridad in the Office of
Inspection and Enforcement Inspection Report which is enclosed with this
letter. Within these areas, the inspection consisted of selective
examinations of procedures and representative records, interviews with
personnel, and observations by the inspector.
Our inspector also verified the steps you have taken to correct the
items of noncompliance brought to your attention in letters dated March
23, 1978 and November 30, 1978.
We have no further questions regarding
your action at this time.
Within the scope of this inspection, no items of noncompliance were
observed.
In accordance with Section 2.790 of the t!RC's " Rules of Practice," Part
2, Title 10, Code of Federal Regulations, a copy of this letter and the
enclosed inspection report will be placed in the NRC's Public Document
Room.
If this report contains any information that you (or your contractor)
believe to be proprietary, it is necessary that you make a written
application within 20 days to this office to withhold such information
from public disclosure.
Any such application must be accompanied by an
affidavit executed by the owner of the information, which identifies the
document or part sought to be withheld, and which contains a statement
of reasons which addresses with specificity the items which will be
considered by the Commission as listed in subparagraph (b)(4) of Section
2.790.
The information sought to be withheld shall be incorporated as
far as possible into a separate part of the affidavit.
If we do not
hear from you in this regard within the specified period, the report
will be placed in the Public Document Room.
,,
,
4
7908270,,
'.
.
,
Boston Edison Company M/C fluclear
2
JUN 2 91979
No reply to this letter is required; however, if you should have any
questions concerning this inspection, we will be pleased to discuss them
with you.
Sincerely,
h
E o
3. Brunner, Chief
Rea, tor Operations and Nuclear
Support Branch
.
Enclosure: Office of Inspection and Enforcement Inspection
Report Number 50-293/79-08
cc w/ encl:
P. J. ficGuire, Pilgrim Station fianager
A. Z. Roisman, Natural Resourses Defense Council (Without Report)