Forwards IE Circular 79-04, Loose Locking Nut on Limitorque Valve Operators
ML19276E842
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 03/16/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Goodwin C
PORTLAND GENERAL ELECTRIC CO.
References
NUDOCS 7903210407
Download: ML19276E842 (1)


Text

16dh d

O(4, UNITED STATES gg 9, e t, NUCLEAR REGULATORY COMMISSION

$.i O I I REGION V D E SUITE 202, W ALNUT C REEK PLAZ A 0

1990 N. C ALIFORNI A BOULEV ARD 4

9

+****

WALNUT CREEK. CALIFORNI A 94596 March 16,1979 Docket No. 50-344 Portland General Electric Company 121 S. W. Salmon Street Portland, Oregon 97204 Attention: Mr. Charles Goodwin, Jr.

Assistant Vice President Gentlemen:

The enclosed IE Circular No. 79-04, is forwarded to you for information.

If there are any questions related to your understanding of the suggested actions, please contact this office.

Sincerely, f/ '.

b,/

Cn$LUWf,

/R.

gelkep

' Director

Enclosures:

1.

IE Circular No. 79 ',

2.

List of IE Circulars Issued in 1979 cc w/encis:

B. Withers, PGE F. C. Gaidos, PGE 790321o % 7

s IE Circular No. 79-04 March 16, 1979 LISTING OF IE CIRCULARS ISSUED IN LAST TMELVE MONTHS Circular Subject Date of Issued To No.

Issue 78-16 Limitorque Valve 7/26/78 All Holders of Actuators Reactor OLs or cps 78-17 Inadequate Guard Training /

10/13/78 All Holders of Qualification and Falsified and applicants Training Records for Reactor OLs.

78-18 UL Fire Test 11/6/78 All Holders of

~

Reactor OLs or cps 78-19 Manual Override (Bypass) 12/28/78 All Holders of of Safety Actuation Signals cps 79-01 Administration of 1/12/79 All Medical Unauthorized Byproduct Licensees except Material to Humans Teletherapy Medical Licensees and each Radiopharmaceutical Suppliers 79-02 Failure of 120 Volt Vital 2/16/79 All Holders of AC Power Supplies Reactor OLs and cps 79-03 Inadequate Guard Training-2/23/79 All Holders of Qualification and Falsified and applicar.ts Training Records for Special Nuclear Material Licenses in Safeguards Group I 79-04 Loose Locking Nut on 3/16/79 All Holders of Limitorque Valve Operators Reactor OLs or cps Enclosure Page 1 of 1

IE Circular No. 79-04 March 16, 1979 Page 2 of 2 Pennsylvania Power and Light Company (PP&L) infomed the t'RC that the generic problem of failure to stake locking nuts exists with Linitorque Type SMC valve operators and Type SMB operators.

PP&L Co. was cdvised of the problem by Bechtel Corporation. The infomation was subnitted to the tiRC on March 2, 1979 as a deficiency at the Susquehanna Stean Electric Station. The Type SMC Instruction and Maintenance Manual SMCI-04-78 and Drawing No. 21-497-0013-3 provide directions for securing the locking nut.

All holders of construction permits and operating licenses should be aware that the potential for valve operator failure exists if the locking nut is not adequately secured. The recommended action is to survey all installed Limitorque Operator Types Sf1B-000 through SMB-5 and Type SitC to determine that the locking nut is secure and to verify that assembly and maintenance instructions contain directions for securing the locking nut either by staking, per the vendor's recommendation, or another acceptable nanner.

flo written response to this Circular is required.

If you require additional information regarding this subject, contact the Director of the appropriate tiRC Regional Office.

IE Circular No. 79-04 March 16, 1979 Page 1 J 2 LOOSE LOCKING NUT ON LIMITORQUE VALVE OPERATORS Description of Circumstances:

On December 8,1978, Fort Calhoun Station Unit No.1 reported that 30 out of 65 Limitorque Type SMB valve operators did not have the locking nut fastened securely in accordance with the manufacturer's recommendation.

If this locking nut is not secure it can loosen and allow the stem nut to move axially to the peint that the splines are disengaged; resulting in a loss of drive to the valve stem.

The licensee reported that several locking nuts were slightly loose but in no instance had the stem nut backed out enough to affect the operation of the valve.

This licensee was made aware of the potential problem by a letter of July 28,1978, from the NSSS supplier, Combustion Engineering, Inc.

Other plants have reported similar findings.

On April 27, 1977, Davis-Besse Nuclear Power Station Unit No.1, reported that two valve operability failures had been caused by locking nuts loosening and falling off. During the ensuing inspection program a total of 65 out of 144 safety related valve operators required staking. Arkansas !!uclear One (AN0), Unit 2, reported on June 29, 1978, that several valve operators required staking. A subsequent inspection at ANO Unit 2 was made by an IE inspector who identified records that 15 out of 17 SMB operators provided by the NSSS supplier (Combustion Engineering Inc.) required sta king. Valve operability failures, resulting from loosened locking nuts, have also been reported by Cooper Nuclear Station (Unusual Event Report 75-5), Browns Ferry Unit 2 report of March 6,1974 and Three liile Island Nuclear Station Unit 1 reports of March 13, 1976 and October 20, 1976.

The corrective action by the licensee in each case was to stake the locking nut.

In June 1978, the Limitorque Corporation issued a supplement to the October 1977 issue of the Type SMB Instruction and Maintenance Manual SMBI 170 that called for the crimping or staking of the locking nuts.

The 1971 issue of the manual had statements for crimping and staking of the lock nuts incorporated into the manual. The stem nut specification drawing provided by Limitorque for Unit Types SMB-000, SMB-00, SMB-0, SMB-1, SMB-2, SMB-3, and Sf1B-4 directs the customer to a Limitorque Drawing No. 21-497-0009-3 for instructions on staking the locking nut; the 9ecification drawing for the SMB-5 unit has a reference to Limitorque Drawing No. 21-497-0010-3 for staking instructions.

Bo@