ML19276E507
| ML19276E507 | |
| Person / Time | |
|---|---|
| Site: | Crystal River |
| Issue date: | 03/08/1979 |
| From: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Stewart W FLORIDA POWER CORP. |
| References | |
| NUDOCS 7903140428 | |
| Download: ML19276E507 (1) | |
Text
'
-~ -- i s a - -
.wr.r a.
.. c r r-h-....
u 7 zmid pm arcOg UNITED STATES Td-30 @
f jo, NUCLEAR REGULATORY COMMISSION
(,g R EGloN 11 g
f
.E 101 M ARIETT A STRE ET. N.W.
[
ATLANTA. GEORGIA 30303 o
%,..... f MAR 8 1979 In Reply Refer To:
RII:JPO 50-302 Florida Power Corporation Atta:
Mr. W. P. Stewart, Director Power Production P. O. Box 14042, Mail Stop C-4 St. Petersburg, Florida 33733 Gentlemen:
The enclosed Bulletin 79-02 is forwarded to you for action.
A written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, m.6 ames P. O'Reilly D ector
Enclosure:
IE Bulletin No. 79-02 cc w/ encl:
G. P. Beatty, Jr.
Nuclear Plant Manager P. O. Box 1228 Crystal River, Florida 32629 7903140 @ s
UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 March 8, 1979 IE Bulletin No. 79-02 PIPE SUPPORT BASE PLATE DESIGNS USING CONCRETE EXPANSION ANCHOR BOLTS Description of Circu= stances:
While performing inservice inspections during a March-April 1978 refueling outage at Millstone Unit 1, structural failures of piping supports for safety equipment were observed by the licensee. Subsequent licensee inspections of undamaged supports showed a large percentage of the concrete anchor bolts were not tightened properly.
Deficiency reports, in accordance with 10 CFR 50.55(e), filed by Long Island Lighting Company on Shoreham Unit 1, indicate that design of base plates using rigid plate assumptions has resulted in underestima-tion of loads on some anchor bolts.
Initial investigation indicated that nearly fif ty percent of the base plates could not be assumed to behave as rigid plates.
In addition, licensee inspection of anchor bolt installations at Shoreham has shown over fif ty percent of the bolt installations to be deficient.
Vendor Inspection Audits by NRC at Architect Engineering firms have shown a wide range of design practices and installation procedures which have been employed for the use of concrete expansion anchors.
The current trends in the industry are toward more rigorous controls and verification of the installation of the bolts.
The data available on dynamic testing of the concrete expansion anchors show fatigue failures can occur at loads substantially below the bolt static capacities due to material imperfections or notch type stress risers.
The data also show low cycle dynamic failures at loads below the bolt static capacities due to joint slippage.
Action to be Taken by Licensees and Permit Holders:
For pipe support base plates that use concrete expansion anchor bolts in Seismic Category I systems as defined by Regulatory Guide 1.29, " Seismic Design Classification" Revision 1, dated August 1973 or as defined in the applicable FSAR.
1.
Verify that pipe support base plate flexibility was accounted for in the calculation of anchor bolt loads.
In lieu of supporting analysis justifying the assumption of rigidity, the base plates 1 of 3
IE Bulletin No. 79-02 March 8, 1979 should be considered flexible if the unstiffened distance between the member welded to the plate and the edge of the base plate is greater than twice the thickness of the plate. If the base plate is determined to be flexible, then recalculate the bolt loads using
~~
an appropriate analysis which will account for the effects of shear - tension interaction, minimum edge distance and proper bolt spacing.
This is to be done prior to testing of anchor bolts. These calculated bolt loads are referred to hereafter as the bolt design loads.
2.
Verify that the concrete expansion anchor bolts have the following minimum factor of safety between the bolt design load and the bolt ultimate capacity determined from static load tests (e.g. anchor bolt manufacturer's) which simulate the actual conditions of installation (i.e., type of concrete and its strength properties):
a.
Four - For wedge and sleeve type anchor bolts, b.
Five - For shell type anchor bolts.
3.
Describe the design requirements if applicable for anchor bolts to withstand cyclic loads (e.g. seismic loads and high cycle operating loads).
4.
Verify from existing QC documentation that design requirements have been met for each anchor bolt in the following areas:
(a)
Cyclic loads have been considered (e.g. anchor bolt preload is equal to or greater than bolt design load).
In the case of the shell type, assure that it is not in contact with the back of the support plate prior to preload testing.
(b) Specified design size and type is correctly installed (e.g. proper embedment depth).
If sufficient documentation does not exist, then initiate a testing program that will assure that minimum design requirements have been met with respect to sub-items (a) and (b) above. A sampling technique t
is acceptable. One acceptable technique is to randomly select and test one anchor bolt in each base plate (i.e. some supports may have more than one base plate).
The test should provide verification of sub-items
~
(a) and (b) above.
If the test fails, all other bolts on that base plate should be similarly tested. In any event, the test program should assure that each Seismic Category 1 system will perform its intended function.
2 of 3
~
i IE Bulletin No. 79-02 March 8, 1979 5.
All holders of operating licenses for power reactor facilities are requested to complete items 1 through 4 within 120 days of date of issuance of this Bulletin. A reactor shutdown is not required to be initiated solely for purposes of this inspection above. Maintain documentation of any sampling inspection of anchor bolts required by item 4 on site and available for NRC inspection. Report in writing within 120 days of date of Bulletin issuance, to the Director of the appropriate NRC Regional Office, completion of your verifica-tion and describe any discrepancies in meeting items 1 through 4 and, if necessary, your plans and schedule for resolution. For planned action, a final report is to be submitted upon completion of your action. A copy of your report (s) should be sent to the United States Nuclear Regulatory Commission, Office of Inspection and Enforcement, Division of Reactor Operations Inspection, Washington, D.C.
20555. These reporting requirements do not preclude nor substitute for the applicable requirements to report as set forth in the regulations and licenea.
6.
All holders of construction permits for power reactor facilities are requested to complete items 1 though 4 for installed pipe support base plates with concrete anchor bolts within 120 days of date of issuance of this Bulletin. For pipe support base plates which have not yet been installed, document your actions to assure that items 1 though 4 will be satisfied. Maintain documentation of these actions on site and available for NRC inspection. Report in writing within 120 days of date of Bulletin issuance, to the Director of the appropriate NRC Regional Office, completion of your review and describe any discrepancies in meeting items 1 though 4 and, if necessary, your plans and schedule for resolution. A copy of your report should be sent to the United States Nuclear Regulatory Commission, Office of Inspection and Enforcement, Division of Reactor Construction Inspection, Washington, D.C.
20555.
Approved by GAO B180225 (R0072); clearance expires 7/31/80. Approval was given under a blanket clearance specifically for identified generic problems.
Enclosure:
List of IE Bulletins Issued in Last Twelve Months 3 of 3
s IE Bulletin No. 79-02 March 8, 1979 LISTING OF IE BULLETINS ISSUED IN LAST TWELVE MONTHS Sulletin Subject Date Issued Issued To
^
No.
78-03 Potential Explosive 2/8/78 All BWR Power Gas Mixture Accumula-Reactor Facilities tions Associated with with an OL or CP BWR Offgas System Operations 78- 04 Environmental Quali-2/21/78 All Power Reactor fication of Certain Facilities with an Stem Mounted Limit OL or CP Switches Inside Reactor Containment 78-05 Malfunctioning of 4/14/78 All Power Reactor Circuit Breaker Facilities with an Auxiliary Contact OL or CP Mechanism-General Medel CR105X 78-06 Defective Cutler-5/31/78 All Power Reactor Hammer, Type M Relays Facilities with an With DC Coils OL or CP 78-07 Protection afforded 6/12/78 Al! Power Reactor by Air-Line Respirators Facilities wit't. an and Supplied-Air Hoods OL, all class E and F Research Reactors with an OL, all Fuel Cycle Facilities with an OL, and all Priority 1 Material Licensees 78- 08 Radiation Levels from 6/12/73 All Power and Fuel Element Transfer Research Reactor Tubes Facilities with a Fuel Element transfer tube and an OL.
78- 09 BWR Drywell Leakage 6/14/79 All BWR Power Paths Associated with Reactor Facilities Inadequate Drywell with an OL or CP Closures Page 1 of 2
IE Bulletin No. 79-02 March 8, 1979 LISTING OF IE BULLETINS ISSUED IN LAST '1VELVE MONTHS Bulletin Subject Date Issued Issued To No.
78-10 Bergen-Paterson 6/27/78 All BWR Power Hydraulic Shock Reactor Facilities Suppressor Accumulator with an OL or CP Spring Coils 78-11 Examination of Mark I 7/21/78 BWR Power Reactor Contain=ent Torus Facilities for Welds action: Peach Bottom 2 and 3 Quad Cities 1 and 2, Hatch 1. Monti-cello and Vermont Yd.kee 78-12 Atypical Weld Material 9/29/78 All Power Reactor in Reactor Pressure Facilities with an Vessel Welds OL or CP 78-12A Atypical Vald Materia.
11/24/78 All Power Reactor in Reacto: Pressure Facilities with an Vessel Weids OL or CP 78-!3 Failures In Source Heads 10/27/78 All general and of Kay-Ra;/, Inc., Gauges specific licensees Models 7( 50, 7050B, 7051, with the subject 7051B, 7h60, 7060B, 7061 Kay-Ray, Inc.
and 70611.
gauges 73-14 Deterior stion of Burw-N 12/19/78 All GE BWR facilities Components In ASCO with an OL or CP Solenoids 79-01 Environnental Qualifica-2/8/79 All Power Reactor tion of Class IE Equipment Facilities with an C:.. C Page 2 of 2
---i-mi