ML19270F983

From kanterella
Jump to navigation Jump to search

Requests Addl Info to Complete Review of Proposed Mod for Storage of Reactor Cavity Annular Seal Plate During Reactor Operation
ML19270F983
Person / Time
Site: Rancho Seco
Issue date: 03/19/1979
From: Reid R
Office of Nuclear Reactor Regulation
To: Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
References
TAC-49501, NUDOCS 7904090316
Download: ML19270F983 (3)


Text

=_..

[

UNITED STATES y..

' *g NUCLEAR REGULATORY COMMISSION 2

53 D

WASHINGTON, D. C. 20555 V W. 4 )

%,,,~,,.

March 19,1979 Docket No. 50-312 Mr. J. J. Mattimoe Assistant General Manager and Chief Engineer Sacramento Municipal Ut'lity District 6201 S Street P. O. Box 15830 Sacramento, California 95813

Dear Mr. Mattimoe:

We have reviewed your submittal of February 1,1979, describing the proposed modification for storing the reactor cavity annular seal plate during reactor operation.

In order to complete our review of your proposal, we find that we need additional information.

Specifically, we request that you provide the following:

1.

A more detailed description of the proposed storage

~

system with clear drawings showing a plan view and an elevation of the storage system.

In addition, provide the significant dimensions of the structure.

2.

A description and the results of any analysis performed to arrive at the conclusion that the proposed modification is acceptable.

Include a listing of the materials used for the structure. Also include the Codes, code allowables, and loading combinations used in the analysis.

Indicate to what extent this design complies with the applicable Standard Review Plans and Regulatory Guides for seismic Category 1 structures.

3.

A description of the fabricating techniques used in the construction at the seal ring support.

Specifically show typical welded and bolted joints and describe the quality control utilized in the manufacture of the support.

790409t 3 /(,

.e Sacramento Municipal Utility District cc: David S. Kaplan, Secretary and General Counsel 6201 S St+eet Post Of fice Box 15830 Sacramento, Cali ornia 95813 Mr, Robert B. ',orsum Babcock & Wilcox Nuclear Power Generation Division Suite,a20, 7735 Old Georgetown Road Bethesda, Maryland 20014 Business and Municipal Department Sacramento City-County Library 828 I Street Sacramento, California 95814 i

4

Mr. J. J. Mattimoe It is requested that you provide this information within 30 days of the receipt of this letter.

Sincerely, wI' hf.

3:

Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors cc: See next page

.