DA11tYLAND POWER C00PEftATIVE Ea Sone, Ohconan
$4601 January 26, 1979 In reply, please refer to LAC-6087 Director of Nuclear Reactor Regulation ATTN:
Mr. Dennis L.
Ziemann, Chief Operating Reactors Branch #2 Division of Operating Reactors U.
S. Nuclear Regulatory Commission Washington, D.
C.
20555
SUBJECT:
DAIRYLAND POWER COOPERATIVE LA CROSSE BOILING WATER REACTOR (LACBWR)
PROVISIONAL OPERATING LICENSE NO. DPR-45 SYSTEMATIC EVALUATION PROGRAM (SEP)
REQUIREMENTS FOR ISOLATION OF HIGH AND LOW PRESSURE SYSTEMS
Reference:
(1)
NRC Letter, Ziemann to Linder, dated December 21, 1978.
Gentlemen:
Your letter (Reference 1) requested verification of correctness of data presented in the reference table as well as additional information pertaining to Safety Topic V-ll.A.
We have revised the enclosed table and verified accuracy and completeness of the information as it applies to isolation of Low Pressure Systems from Reactor Coolant Systems.
If there are any questions regarding this submittal, please con-tact us.
Very truly yours, DAIRYLAND POWER COOPERATIVE va k
/us Frank Linder, General Manager FL:PJW:af cc:
J.
Keppler, Reg. Dir., NRC-DRO III 7902050W 4
PLANT:
LA CROSSE EVALUATION Di ISOLATION OF LOW PRESSURE SYSTEMS FROM REACTOR COOLANT SYSTEM MEETS REDUNDANCY TESTABLE LOCATION OF METHOD OF DIRECT INTERFACES,4 ISOLATING 0F TYPE BETWEEN HP/LP CHECK VALVE PRESSURE METHOD 0 3
CRITERIA ISOLATION VALVES VALVES INTERFACE ORIENTATION REDUCTION ISOLATI0f Water Cleanup System 6 Inlet NOTE:
Water cleanup system designed for reacter co,olant system pressure.
Discharge ECCS Law Pressure Yes Yes 2CK (38 No 1C Horizontal NA Auto Injection 001 and 38-26-002)
Low Pressure Core Yes Yes IMO (53 No 1C Horizontal NA Auto Spray 2 001) 1CK (53-26-001)
Sampling System None penetrate containment boundary.
RliR Systen -
Suction Side NOTE:
RHR system is designed for reactor coolant system pressure.
Discharge Side
" '~'
1C - Inside Reactor Containment Building.
~
./
REMARKS Called primary purification system. High pressure system.
Reference Allis-Chalmers Specifi-cation 41-585 - Piping Systems for Reactor Pirat. Maximum working pressure 1400 psig.
Called alternate core spray system.
Operates on low reactor water level coincident with low differ-ential pressure reactor versus Containment Building.
Sam 61ing system designed for reactor coolant system pressure, gw Called decay heat cooling system-high pressure s" stem.
Reference Allis-Chalmers Specification 41-858 - Piping Systems for Reactor Plant. Maximum working pressure 1400 psig.
_