ML19269E132

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 70-0033/79-04 on 790305-09
ML19269E132
Person / Time
Site: 07000033
Issue date: 04/26/1979
From: Martin W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Conroy D
TEXAS INSTRUMENTS, INC.
Shared Package
ML19269E129 List:
References
NUDOCS 7906260565
Download: ML19269E132 (2)


Text

4*

UNITED STATES c,

ye

  • g NUCLEAR REGULATORY COMMISSION j

j REGION l

'C 631 PARK AVENUE

'a{

KING OF PRUS$1A PENNSYl.VANI A 19405 APR 2 6 84 Docket No. 70-33 Texas Instruments Incorporated ATTN: Mr. Daniel Conroy Manager, Metals Systems Division Manufacturing 34 Forrest Street Attleboro, Massachusetts 02703 Gentlemen:

Subject:

Inspection 70-33/79-04 This refers to the inspection conducted by Mr. Edward W. Jones, Jr. of this office on March 5-9, 1979 of activities authorized by NRC License No. SNM-23 and to the discussions of our findings held by Mr. Edward W.

Jones, Jr. with Mr. Daniel Conroy at the conclusion of the inspection.

Areas examined during this inspection are described in the Office of Inspection and Enforcement Inspection Report which is enclosed with this letter. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.

Our inspector also verified the steps you have taken to correct the item of noncompliance brought to your attention in a letter dated November 15, 1978. We have no further questions regarding your action at this time.

Based on the results of this inspection, it appears that one of your activities was not conducted in full compliance with NRC requirements, as set forth in the Notice of Violation, enclosed herewith as Appendix A.

This item of noncompliance has been categorized into the levels as described in our correspondence to you dated December 31, 1974.

This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201 requires you to submit to this office, within twenty (20) days of your receipt of this notice, a written statement or explanation in reply including:

(1) corrective steps which have been taken by you and the results achieved; (2) corrective steps which will be taken to avoid further items of noncompliance; and (3) the date when full 'c.ompliance will be achieved.

2131 356 06260F C

79

l Texas Ins '.ruments Incorporated 2

APR Z 61979 In acco' dance with Section 2.790(d) of the NRC's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, documentation of findings of your control and accounting procedures for safeguarding special nucleat materials and your facility security procedures are exempt from disclo;ure; therefore, the enclosures to this letter, and your response to this letter will not be placed in the Public Document Room and will receive limited distribution.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, Walter G. Martin, Chief Safeguards Branch

Enclosure:

1. Appendix A, Notice of Violation (Contains 2.790 Info)
2. Office of Inspection and Enforcement Inspection Report Number 70-33/79-04 (Contains 2.790 Info) cc: (w report cover sheet only)

W. George, Assistant Vice President and t% nager Metallurgical Materials Division F. L. Sherman, Manager, HFIR Project G

G 2131 357 a

1

..