William J. Cahill, Jr.

  • * - * -
  • Via Prcw:Pnt Conscheated Ed: son Comany cf New York. Inc.

4 trong F% e. New York. N Y 10003 Teleonone (212) 460-3519 February 9, 1979 Mr. Harold R. Denton, Director Office of Nuclear Peactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Re: Consolidated Edison Company of New York, Inc.

(Indian Point Station, Unit No. 2)

Docket No. 50-247

Dear Mr. Denton:

Consolidated Edison Company of New York, Inc. (Consolidated Edison)

. transmits herewith three (3) signed originals and forty (40) copies of a document entitled, " Application for Amendment to Operating License,'

sworn to on February 9,1979. This Application requests an amendment to the Technical Specifications for Indian Point Unit No. 2. The proposed Technical Specification changes, contained in Attachment A to this Application, would revise Table 3.12-1 to reflect redesign of the support systems of certain safety-related pipe lines. The purpose of the redesign is to improve the reliability of the sub-ject piping systems by reducing the number of hydraulic snubbers necessary to satisfy design criteria. A Safety Evaluation of the proposed changes is presented in Attachment B to this Application.

During the performance of the support system redesign, Consolidated Edison utilized the outside consulting services of Associated Technologies, Inc. (ATI) and EDS Nuclear (EDS). Their engineering and analytical work provided the basis for hydraulic snubber reduction on the redesigned piping support systems. Accordingly, Consolidated Edison transmits herewith forty (40) copies of the following consultant reports which are the supporting documents for the redesign effort and the requested Technical Specification changes:

(1) Report No. 03-00101, Rev. O, " Indian Pvint Unit 2 Generating Station, Buchanan, New York - Piping Systems Hydraulic Shock Suppressor Removal Study,"

dated April, 1978; Associated Technologies, Inc.

(2) Report No. 03-00102, Rev. O, " Indian Point Unit 2 Generating Station Buchanan, New York - Piping Systems Hydraulic Shock Suppressor Analysis for Removal," dated July, 1978; Associated Technologies, Inc.

79021s53( q /

(3) Report No. NYO-78-005, Rev. O, " Support System Redesign for Piping Runs on North Half of Containment for Indian Point Unit 2," dated January, 1979; EDS Nuclear.

Since most of the work associated with the hydraulic snubber reduction program requires an extended plant outage for completion, we are planning to have the entire program completed by the end of the upcoming refueling. Accordingly, Consolidated Edison respectfully requests an expedited review of this Application by the Regulatory Staff and issuance of the appropriate license amendment by April 2, 1979. Since the refueling outage is currently projected to begin in June, 1979, approval of our request by Aprii 2, 1979 would allow sufficient time for factoring the various support modification jobs into the overall outage schedule and for purchase of the necessary materials. Should you or your Staff have any questions regarding this Amendment request, we will be pleased to discuss them with you at your convenience.

In accordance with 10 CFR 170.22, this Application has been determined to be CLASS III, as it involves a single issue and has been deemed not to involve a significant hazards consideration.ne amount Therefore, as of S4,000.00 required by regulation, enclosed is a check L.

as the filing fee. This payment is being made under protest, and Consolidated Edison reserves the right to challenge the validity of the imposition of these fees and the basis for the determination of the amounts of the fees.

A Certificate of Service is enclosed.

Very truly yours, j - - <

/ j,7 ,d O -

William J. Cahill, Jr.

Enclosures Vice President cc: Hon. George V. Beg 6ny (w/ encl.)

UNITED STATES OF AITRICA MUCLEAR REGULATORY CO!"tISSION In the Matter of )

)

CONSOLIDATED EDISON COMPANY ) Docket No. 50-247 OF NEW YORK, INC. )

(Indian Point Station, )

Unit No. 2) )

CERTIFICATE OF SERVICE gs I certify that I have, this sday of February, 1979, served the foregoing document entitled, " Application for Amendment to Operating License," sworn to on February 9, 1970, and the three (3) accompanying reports dated April, 1978, July, 1978, and January, 1979, by mailing two copies thereof, first class postage prepaid and properly addressed to the following person:

Fon. George V. Begany Mayor, Village of Buchanan 188 Westchester Avenue Buc.hanan, New York 10511

.. s -,

h~gw \, 1;, -. _ s ~ _ ,, - ]

Joyce P. Davis

~ . ./