Forwards IE Info Notice 79-01,Bergen-Paterson Hydraulic Shock & Sway Arrestors (Hssa)
ML19269C714
Person / Time
Site: Davis Besse 
Issue date: 02/02/1979
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Jeffery Grant
TOLEDO EDISON CO.
Shared Package
ML19269C715 List:
References
NUDOCS 7902120113
Download: ML19269C714 (1)


Text

.T s

L f*"*%,

UNITED STATES

,,,4 NUCLEAR REGULATORY COMMISSION

/

j

[,'e REGION 111 i

799 RoOSEVE LT RO AD t

g G LEN E LLYN, ILLINOIS 60137 Docket No. 50-346 Toledo Edison Company ATTN:

Mr. James S. Grant Vice President - Energy Supply Edison Pla.za 300 Madison Avenue Toledo, OH 43652 Gentlemen:

s This Information Notice is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time. If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions. If you have questions regarding this natter, please contact the Director of the appropriate NRC Regional Office.

Sincerely, O.-.,_% faukw dames G. Keppler Director

Enclosures:

1.

IE Information Notice No. 79-01 2.

List of IE Information Notices Issued in 1979 cc w/encls:

Mr. T. Murray, Station Superintendent Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR JSIC VTIC U. Young Park, Pcwer Siting Comr:lission 790212Ol/3

U.S. NUCLEAR REGULATORY COMMISSION

_~

OFFICE OF INSPECTION AND ENFORCEMENT REGION III February 2,1979 IE Information Notice No. 79-01 BERGEN-PATERSON HYDRAULIC SHOCK AND SWAY ARRESTORS (HSSA)

On December 4, 1978, Rancho Seco Nuclear Generating Station reported the failure or seven Bergen-Paterson HSSA (Snubber) units to lockup in the compression direction and the failure of one additional unit to lockup in the extension direction. These failures were identified during surveillance testing and the affected models included HSSA-3-6, HSSA-10-6 and HSSA-20-6. When the units were disassembled, the licensee observed damage to the popet valve and seat on the conpression side of the valve blocks of the seven units that failed in the compression direction.

It was also observed that five of the seven units had the The licensee poppet spring entrapped between the poppet and the seat.

attributed the seven failures in the compression direction to abusive handling during compreasion of the units for installation following testing at the previous refueling outage. The cause of the single failure in the extension direction has not been determined. In addition to exercising greater care in reinstallation, the licensee committed to functionally test all Bergen-Paterson snubbers subjected to transient conditions which cause either physical damage to or significant movement of piping. This testing will include verification of piston movement, lockup and bleed. The Bergen-Paterson Technical Maintenance Manual reco=cends that additional inspections should be made on units which may,have participated in an unusual shock occurrence involving known damage to,' piping or equipment.

On January 3, 1979, the licensee reported that the decay heat removal system had been subjected to a transient condition in the form of a

" water hammer." This transient, caused pipe movement great enough to damage two rigid pipe support wall attachments. The subsequent functional testing of the affected Bergen-Paterson units revealed that one of seven units failed the lockup test.

This unit (Model No. HSSA-3-6) was disassembled and damage to the poppet valve and seat was observed.

The damage to the poppet valves is presently being reviewed by both the licensee and Bergen-Paterson. At this time, the cause of damage has not been completely defined nor has appropriate corrective action been determined. Other licensees have reported instances of poppet valve damage; however, the cause and extent of damage are not known at this time.

h 7902120059

February 2, 1979 IE Information Notice No. 79-01 This information is provided as an early notification of a possibly It is expected that recipients will review the significant matter.

Ne specific information for possible applicability to their facilities.

If further NRC evaluations action or response is requested at this time.

so indicate, an IE Circular or Bulletin will be issued to recommend or -

If you have questions regarding request specific licensee actions.

this matter, please contact the Director of the appropriate NRC Regional Office.