ML19269C286

From kanterella
Jump to navigation Jump to search
LER 78-065/03L-0 on 781228:during a Surveillance Test on Control Room Emergency Habitability Sys,Sys Could Not Maintain the Room at Required 1/8 Inch Wc Above Outside Atmosphere.Caused by Leaks in Control Room
ML19269C286
Person / Time
Site: Beaver Valley
Issue date: 01/26/1979
From: Werling J
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19269C285 List:
References
LER-78-065-03L, LER-78-65-3L, NUDOCS 7901310049
Download: ML19269C286 (1)


Text

. .-. . . _ . . . . _ . _

NRC FORM ';46 .

U.S. NUCLEAR REGULATORY COMMISSION

. (7 77)

  • LICENSEE EVENT REPORT CONTROL BLOCK: & LEASE PRINT OR TYPE ALL REQUIRED INFO 6MATION) 1 l l l l l lh 6

o li l P l A l B l V l S l 1pl 0 l0 l- l 0 l0 l 0 l 0 l 0 l- l0 l 025 l@l4 26 l1LICENSE l1 l1TvrE l1JGl@l 57 car l sd l@

7 8 9 LICENSEE CODE 84 15 LICENSE NuMeER CON'T RE'OR7 g 3uc l60L @l610 l 5 lDOCK 0 l ET0NUM8ER l 0 l 3 l 3hal 4 @l l EVENT t>3 l 2 l0 2ATEl 8 l 7 l 8 @l 0REPORT 74 75 1l 2l 6l 7l9l@

0 ATE 80 7 8 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h

[TTT] l While performing a surveillance test on the control room emergency habitability (TTT]l system, it was determined the system could not maintain the control room at the g

[777]l required 1/8 inch WC above the outside atmosphere. An investigation was begun to l 0 s I determine any source of leakage. The health and safety of the general public was l ITTR I not jeopardized. When corrective action was complete, the test was reperfo_rmed I C 7 Isatisfactorily. 1 O s ! I

  • E'E C0$I StsCi$E COMPONENT CODE SUB OD'E S E F6T97 7 8 9 Is Ic l@ LxJ@ LLJ@ l zi zl zl zl zi 7I@ Iz l@ Iz l@

to 11 12 13 18 19 20

,, SEQUENTIAL OCCURRENCE REPORT REVISION LE R EVENT YEAR REPORT NO. CODE TYPE No.

@ ,agg/RO g 1718 l-l 10161 si l/l I 01 31 lL ! L---J 101 2% 22 23 24 26 27 28 29 30 33 32 N AC C ONP NT ME HOURS S8 i POR 8. 5 PPLIER MANUF CTURER gl34Zl@

I 33 l35Z l@ l36Z l@ l 0l 0l 0l 0l 37 40 W@

41 l42N l@ 43 Zl@ l44Z l 9 l 9 l 947l@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 i O lThe incident resulted from numerous leaks in the control room. Leaks were located g i i l around doors, cable penetrations and penetrations r ade for installation of i 2 1 modifications. The leaks around doors and cable penetrations were sealed. l i 3 l Penetrations made for modifications will be controlled so that they do not remain l g l open for extended periods if work is not being performed. l 7 9 80 ST  % POWER OTHER STATUS dis O RY DISCOVERY DESCRIPTION y W @ l0l0l0l@l N/A l l B l@l Surveillance test l ACTIVITY CO ENT aELEASEo OP aELE ASE AuOusT OF ACTIVITY LOCATION OP RELEASE 1 6 N/A N/A

@ l Zl@ l l l l PERSONNEL EXPOS ES NUuBER TveE otSCRiPTiON @

i 7 l0l0l0lhlZlhl" 2 N/A l PERSONN E L iN;u'RitS "

NUVBER DESCRIPTION @

7 1 a 8 9 l0 0l0l@l 11 12 N/A go l

LOSS OF OR D AMAGE TO FACILITY TYPE 9 [Zj@, DESCRIPTION

, N/A l 7 8 3 to go ISSUE DE CRIPTION 7

2 O e s hl to N/A l se llllllllll ll lj e,

ao. :

7 9 01 3 1 Oy,y, o, ,,,,,,,, _ .r. A. Werling

,,0y, 412-643-12s8 o