| | | Reporting criterion |
|---|
| 05000334/LER-1978-001-40, /040 on 771025:reporting Level in ETS for Gross Beta Particles Was Reached or Exceeded 771003-10.Caused by Chinese Bomb Fallout.No Corrective Action Appropriate | /040 on 771025:reporting Level in ETS for Gross Beta Particles Was Reached or Exceeded 771003-10.Caused by Chinese Bomb Fallout.No Corrective Action Appropriate | |
| 05000334/LER-1978-001, Forwards LER 78-001/040 | Forwards LER 78-001/040 | |
| 05000334/LER-1978-043-01, /01T-0:on 780728,electrical Fault Caused Generator Trip & Loss of Power.Caused by Main Generator Field Flash Relay Out of Stop.Failure Could Not Be Duplicated.Generator Tested Satisfactory | /01T-0:on 780728,electrical Fault Caused Generator Trip & Loss of Power.Caused by Main Generator Field Flash Relay Out of Stop.Failure Could Not Be Duplicated.Generator Tested Satisfactory | |
| 05000334/LER-1978-048-03, /03L-0 on 780221:during Rev Test Data on 780825, Noted That Final Setpoint Valve Entered on 780221 for RCS Loop 1B Cold Leg Loop Stop Valve Relief Line Flow Interlock Was 124 Gpm Caused by Improper Setpoint | /03L-0 on 780221:during Rev Test Data on 780825, Noted That Final Setpoint Valve Entered on 780221 for RCS Loop 1B Cold Leg Loop Stop Valve Relief Line Flow Interlock Was 124 Gpm Caused by Improper Setpoint | |
| 05000334/LER-1978-048, Forwards LER 78-048/03L-0 | Forwards LER 78-048/03L-0 | |
| 05000334/LER-1978-053, Forwards LER 78-053/01T-0 | Forwards LER 78-053/01T-0 | |
| 05000334/LER-1978-053-01, /01T-0:on 781026,error Noted in Original Piping Stress Analysis for on Steam Infection Line.Error Caused by Misapplication of Simplified Analysis Technique Employed During Original Design.Corrective Action Implemented | /01T-0:on 781026,error Noted in Original Piping Stress Analysis for on Steam Infection Line.Error Caused by Misapplication of Simplified Analysis Technique Employed During Original Design.Corrective Action Implemented | |
| 05000334/LER-1978-054-03, /03L-0 on 781005:During Surveillance Test on Containment High Pressure Bistable,The Setpoint Was 2.3 Lbs Instead of 2.0.Caused by Faulty Elco Connector on Loop Signal Comparator.Comparator Was Replaced | /03L-0 on 781005:During Surveillance Test on Containment High Pressure Bistable,The Setpoint Was 2.3 Lbs Instead of 2.0.Caused by Faulty Elco Connector on Loop Signal Comparator.Comparator Was Replaced | |
| 05000334/LER-1978-054, Forwards LER 78-054/03L-0 | Forwards LER 78-054/03L-0 | |
| 05000334/LER-1978-055-03, /03L-0 on 781013:channel N41 Rate Trip Set at 11.8% in 2.2 Seconds Rather than Limit of 5.5% in 2 Seconds. Caused by Inadvertent Readjustment or Improper Calibr of the Setpoint | /03L-0 on 781013:channel N41 Rate Trip Set at 11.8% in 2.2 Seconds Rather than Limit of 5.5% in 2 Seconds. Caused by Inadvertent Readjustment or Improper Calibr of the Setpoint | |
| 05000334/LER-1978-055, Forwards LER 78-055/03L-0 | Forwards LER 78-055/03L-0 | |
| 05000334/LER-1978-056, Forwards LER 78-056/03L-0 | Forwards LER 78-056/03L-0 | |
| 05000334/LER-1978-056-03, /03L-0 on 781011:vent Exhaust Monitor RM-VS-101 Removed from Svc for Grab Samples.Sample Not Taken for One Day Due to Personnel Error.(For Ltr See ANO 7811170172.) | /03L-0 on 781011:vent Exhaust Monitor RM-VS-101 Removed from Svc for Grab Samples.Sample Not Taken for One Day Due to Personnel Error.(For Ltr See ANO 7811170172.) | |
| 05000334/LER-1978-057, Forwards LER 78-057/04L-0 | Forwards LER 78-057/04L-0 | |
| 05000334/LER-1978-057-04, /04L-0 on 781110:records Review Showed Gaseous Waste Monitor RM-GW-108B Was Inoper from 780210-13 & No Results of Grab Samples Could Be Located,Due to Failure by Radcon Personnel to Obtain the Samples | /04L-0 on 781110:records Review Showed Gaseous Waste Monitor RM-GW-108B Was Inoper from 780210-13 & No Results of Grab Samples Could Be Located,Due to Failure by Radcon Personnel to Obtain the Samples | |
| 05000334/LER-1978-058-04, /04T-0 on 781108:chlorination Was Performed on River Water Headers During Plant Shutdown & Free Chlorine Residual Exceeded Allowable 0.5ppm,due to Personnel Error | /04T-0 on 781108:chlorination Was Performed on River Water Headers During Plant Shutdown & Free Chlorine Residual Exceeded Allowable 0.5ppm,due to Personnel Error | |
| 05000334/LER-1978-058, Forwards LER 78-058/04T-0 | Forwards LER 78-058/04T-0 | |
| 05000334/LER-1978-059, Forwards LER 78-059/03L-0,LER 78-060/03L-0 & LER 78-061/03L-0 | Forwards LER 78-059/03L-0,LER 78-060/03L-0 & LER 78-061/03L-0 | |
| 05000334/LER-1978-059-03, /03L-0 on 781108:during Performance of Type C Containment Penetration Leak Test,12 Valves Were Found to Be Leaking at a Rate Greater than Maximum Measurable on Leak Rate Monitor Caused by Excessive Valve Leakage | /03L-0 on 781108:during Performance of Type C Containment Penetration Leak Test,12 Valves Were Found to Be Leaking at a Rate Greater than Maximum Measurable on Leak Rate Monitor Caused by Excessive Valve Leakage | |
| 05000334/LER-1978-060-03, /03L-0 on 770718:during Review of Surveillance Test Records It Was Determined That Monthly Test for 1B Rprw Pump Was Not Performed by 770718 as Req.Caused by Improper Sched of Surveillance Test | /03L-0 on 770718:during Review of Surveillance Test Records It Was Determined That Monthly Test for 1B Rprw Pump Was Not Performed by 770718 as Req.Caused by Improper Sched of Surveillance Test | |
| 05000334/LER-1978-061-03, /03L-0 on 781012:during Performance of Containment Isolation Check Valve Surveillance test,1A RCP Seal Injection spring-loaded Check Valve Was Found to Have an Opening Pressure of 11.5 Psid.Caused by Excess Force | /03L-0 on 781012:during Performance of Containment Isolation Check Valve Surveillance test,1A RCP Seal Injection spring-loaded Check Valve Was Found to Have an Opening Pressure of 11.5 Psid.Caused by Excess Force | |
| 05000334/LER-1978-062-03, /03L-0 on 780313:constant for Control Rod Changed from 12 to 20 Steps Because Nuisance Alarms Caused Rod Position Deviation Monitor to Be Inoperable.Caused by Failure to Check Negative Effects Before Changing Constant | /03L-0 on 780313:constant for Control Rod Changed from 12 to 20 Steps Because Nuisance Alarms Caused Rod Position Deviation Monitor to Be Inoperable.Caused by Failure to Check Negative Effects Before Changing Constant | |
| 05000334/LER-1978-062, Forwards LER 78-062/03L-0,78-063/03L-0 & 78-064/03L-0 | Forwards LER 78-062/03L-0,78-063/03L-0 & 78-064/03L-0 | |
| 05000334/LER-1978-063-03, /03L-0 on 781222:faulty Comparator in 1A Main Steam Pressure Instrument Loop.Caused by Broken Lead on a Capacitor on Comparator in Main Stream Pressure Channel | /03L-0 on 781222:faulty Comparator in 1A Main Steam Pressure Instrument Loop.Caused by Broken Lead on a Capacitor on Comparator in Main Stream Pressure Channel | |
| 05000334/LER-1978-064-03, /03L-0 on 781222:comparator in 1A Main Steam Flow Instrumentation Channels Inoperable;Channel Bistables Tripped.Caused by Failure of Comparator | /03L-0 on 781222:comparator in 1A Main Steam Flow Instrumentation Channels Inoperable;Channel Bistables Tripped.Caused by Failure of Comparator | |
| 05000334/LER-1978-065, Forwards LER 78-065/03L-0 | Forwards LER 78-065/03L-0 | |
| 05000334/LER-1978-065-03, /03L-0 on 781228:during a Surveillance Test on Control Room Emergency Habitability Sys,Sys Could Not Maintain the Room at Required 1/8 Inch Wc Above Outside Atmosphere.Caused by Leaks in Control Room | /03L-0 on 781228:during a Surveillance Test on Control Room Emergency Habitability Sys,Sys Could Not Maintain the Room at Required 1/8 Inch Wc Above Outside Atmosphere.Caused by Leaks in Control Room | |
| 05000334/LER-1978-066, Forwards LER 78-066/03L-0 | Forwards LER 78-066/03L-0 | |
| 05000334/LER-1978-066-03, /03L-0 on 781230:neither Containment Sump Pump Would Operate,Due to Misadjusted Impeller & Bad Bearings.A Pump Readjusted & B Pump Relaced.Pumps Returned to Normal Svc | /03L-0 on 781230:neither Containment Sump Pump Would Operate,Due to Misadjusted Impeller & Bad Bearings.A Pump Readjusted & B Pump Relaced.Pumps Returned to Normal Svc | |
| 05000334/LER-1978-067, Forwards LER 78-067/01T-0 | Forwards LER 78-067/01T-0 | |
| 05000334/LER-1978-067-01, /01T-0 on 781220:during Containment Type a Leak Test,Excessive Leakage Was Found at Containment Air Ejector Penetration Isolation Valves,Caused by Warped Rubber Valve Seats | /01T-0 on 781220:during Containment Type a Leak Test,Excessive Leakage Was Found at Containment Air Ejector Penetration Isolation Valves,Caused by Warped Rubber Valve Seats | |