ML19269C018

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in IE Insp Repts 50-317/78-34 & 50-318/78-31.Corrective Actions: Surveillance Test Procedure Revised to Incorporate More Detailed Instructions
ML19269C018
Person / Time
Site: Calvert Cliffs  
Issue date: 12/22/1978
From: Lundvall A
BALTIMORE GAS & ELECTRIC CO.
To: Brunner E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19269C009 List:
References
NUDOCS 7901190207
Download: ML19269C018 (2)


Text

o

~'~

h B ALTIMORE G AS AND ELECTRIC COMPANY P.O. B O X 1475 B A LTI M O R E. M A R Y t. A N O 2120 3 ARTM 4 2 JN OVALL dR.

v.ca Ser siotest sr, December 22, 1978 U. S. Nuclear Regulatory Ccmmission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Attention:

Eldon J. Brunner, Chief Reactor Operations and Nuclear Support Branch Gentlemen:

This refers to your Inspection Reports 50-317/78-34 and 50-318/78-31, which transmitted an item of apparent non-compliance with NRC require-men ts. Enclosure (1) to this letter is a written statement in reply to the item noted in Appendix "A" of your letter of Noverrber 30, 1978.

Should you have further questions regarding this reply, we will be pleased to discuss them with you.

Very truly yours, It ; ', - g li S L..

,~

A'. E. Lundvall, Jr.

Vice President - Supply, AEL/JTC/ds Enclosure 7901190707

ENCLOSURE (1)

REPLY TO NRC LETTER DATED NOVEMBER 30, 1978 flRC INSPECTION REPORT 50-317/78-34; 50-318/78-31 This deficiency occurred because the Surveillance Test Procedure imple-menting the reauirements of T.S. 4.1.3.1.3 does not adeauately describe the procedure for verifying and documentina that a Potion Inhibit Signal will prevent any Control Element Assembly (CEA) from being misaligned from all other CEAs in its group by more than 7.5 inches. The Surveill-ance Test Procedure is being revised to incorporate more detailed instructions for perfoming the required surveillance. This procedural change will be comoleted by January 1,1979 and will serve to prevent recurrence of this event.