a w.

g H E L PI N G BUILO ARKANSAS ARK ANS AS POWER & LIGHT COMPANY P O. BOX 551 = LITTLE ROCK. ARKANSAS 72203-(501)3714191 February 23, 1979 OONALO A. RUETER OIRECTOR TECHNICAL AND ENVIAONMENTAL GERVICES 1-029-13 2-029-10 Mr. K. V. Seyfrit, Director Office of Inspection 6 Enforcement U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011

Subject:

Arkansas Nuclear One - Units 1 and 2 Docket Nos. 50-313 and 50-368 License Nos. DPR-51 and NPF-6 Semi-Annual Radioactive Effluent Rcport (File:

0520.3, 2-0520.3)

Gentlemen:

Pursuant to 10CFR 50.36a, enclosed is the subject report for the third and fourth quarters of 1978.

Very truly yours, r

/

/

/

/ 14 s

nw

~

Donald A. Rueter DAR: ERG:1g Enclosure cc:

Mr. John G. Davis, Acting Director Office of Inspection 6 Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Mr. Norman M. Haller, Director Office of Management and Program Analysis U. S. Nuclear Regulatory Commission Washington, D. C. 20555 790301030)

TAX P AvlN T.,

IN V E S TO A OW N E O b

MEMBE A MICOLE SO;*TH UTILITIE S S Y S T E M

E FACILITY--AtJO UtlIT8 1 PEPORT OF RADI0 ACTIVE GAS EFFLUEt4TS DOCKET 50-212 FOR HALFH 2 0F YEARtt1978 ot40TE: TOT =EITHER SEMI (1ST HALF) OR AtitlUAL (2t4D HALF) TOTALS RELEASES JUL AUG SEP TOT

1. GASES (CI) 6.167E O2 4.754E O2 1.041E 02 7,820E 02 2.HALOGEi45 6.125E-06 1.192E-05 1.612E-05 2.190E-02 (CI) 4.H-2(CI) 9.225E-02 7.267E-01 9.653E-01 6.151E 00
5. ALPHA <CI) 2.794E-01 flR
6. MAXIMUM GAS 8.256E 02 5.554E 04 9.591E 01 TJA RELEASE RATE <UCI'SEC) 7A.% APPLICABLE GAS LIMIT 2.014E 01 f4A TC.% PART + I-121 LIMIT
3. -272E-02 t1R 8.

ISOTOPES RELEASED (CI)

PARTICULATES CS-127 7.639E-07 1.150E-06 0.000E-01 1.224E-02 BA-140 0.000E-01 0.000E-01 0.000E-01 0.000E-01 LA-140 0.000E-01 0.000E-01 0.000E-01 0.000E-01 SR -90 0.000E-01 0.000E-01 0.000E-Oi 1.216E-07 CS-124 1.059E-06 1.211E-06 0.000E-01 2.040E-05 SR-89 2.124E-06 2.124E-06 2.124E-06 2.528E-05 HALOGEtts I-121 6.125E-06 1.192E-05 1.612E-05 2.185E-02 I-123 0.000E-01 0.000E-01 0.000E-01 4.541E-06 I-125 O.000E-01 0.000E-01 0.000E-0?.

O.000E-01 GASES KR-85 0.000E-01 0.000E-01 0.000E-01 2.259E 01 XE-12_.

_.272E 02 4.591E 02 5.016E 01 5.029E 02 V.R-88 0.0005-01 0.IiOOE-01 0.000E-01 8.425E 01 KR-87 0.000E-01 0.000E-01 0.000E-01 1.148E 00 KR-SSM 0.000E-01 0.000E-01 0.OOOE-01 1.119E 01 XE-128 0.000E-01 0.000E-01 0.000E-01 6.072E-04 XE-122M 0.000E-01 8.592E-01 0.000E-01 9.274E 00 XE-125 2.895E 02 1.251E 01 5.290E 01 6.929E 02 AR-41 0.000E-01 0.000E-01 0.000E-01 4.757E 00 OTHERS XE-121M 0.000 1.91 0.000 1.972E 02 XE-125M 0.000 0.000 0.000

0. 242 F-18 0.000 0.000 0.000 0.000

BE-7 0.000 0.000 0.000 2.129E-06 K-40 0.000 0.000 0.000 2.284E-07 CR-51 0.000 0.000 0.000 5.015E-06 Mrt-54 0.000 0.000 0.000 0.000 CO-57 0.000 0.000 0.000 4.246E-05 CO-58 2.992E-07 4.999E-06 2.617E-06 2.207E-04 FE-59 0.000 0.000 0.000 0.000 CO-6C 4.026E-07 8.742E-07 7.041E-07 1.296E-05 tJI-65 O.000

0. 000 0.000 0.000 FrJ-F.5 O.000 0.000 0.000 O_000_ __

flB-94 0.000 0.000 0.000 0.000 f1B-95 O.000 0.000 0.000 0.000 ZR-95 0.000 0.000 0.000 1.014E-06 CU-102 0.000 0.000 0.000 2.252E-07 RU-106 0.000 0.000 0.000 0.000 CD-109 0.000 0.000 0.000 0.000 AG-110M O.000 0.000 0.000

'327E-06

~

Sil-112 0.000 0.000 0.000 1.242E-07 CD-112M 0.000

0. 000 0.000 0.000 58-125 0.000 0.000 0.000 0.000 BA-123 0.000 0.000 0.000 0.000 CS-126 0.000 0.000 0.000 2.285E-07 CE-129 0.000
0. 000 0.000 0.000 CE-144 0.000 0.000 0.000 0.000 EU-152 0.000 0.000 0.~000 0.000 HG-202 0.000 0.000 0.000 6.675E-07 U-22.5 0.000 0.000 0.000 0.000 RA-226 0.000 0.000 0.000 2.0206-06 58-124 0.000 0.000 0.000 0.000 TH-228 0.000 0.000 0.000 0 000 f4A-24
0. 000 0.000 3.000 0.000 tifl-56 0.000 0.000 0.000 0.000 CU-64 0.000 0.000 0.000 0.000 BR-84 0.000 0.000 0.000 0.000 RB-88 0.000 0.000 0.000 1.087E-04 RB-89 0.000 0.000 0.000 0.000 T10-99 0.000 0.000 0.000 0.000 SR-91 0.000 0.000 0.000 0.000 Y-91M 0.000
0. 000 0.000 0.000 SR-92 O.000 0.000 0.000 0.000 Y-92 0.000 0.000 0 000 0.000 tJB-97 0.000 0.000 0.000 0.000 ZR-97 0.000 0.000 0.000 0.000 PB-212 0.000 0.000 0.000 0.000 TC-99M O.000 0.000 0.000 0.000 58-122 0.000 0.000 0.000 0.000 I-122 0.000 0.000 0.000 0.000 I-124 0.000 0.000 0.000 0.000 C:5-128 0.000 0.000 0.000 0.000 BR-129 0.000 0.000 0.000
0. 000 W-187 0.000 0.000 0.000 0.000 BI-214
0. 000 0.000 0.000 9.8S9E-06 PB-214 0.000 0.000 0.000 0.000 flP-239 0.000 0.000 0.000 0.000 TE-122 0.000 O. 000 0.000 0.000

RELEA5ES OCT (10V DEC TOT 1.GA5ES(CI) 6.711E 01 0.000E-01 1.027E O2 7.820E 02 2.HALOGEll5 8.789E-05 5.192E-06 5.980E-06 2.190E-02 (CI) 4.H-2(CI) 1.174E 00 2.926E-01 6.294E-01

,6.151E 00

5. ALPHA <CI)

O.000E-01 t4A

6. MAXIMUM GAS 1.107E 02 2.025E-01 2.274E 05 NA PELEASE RATE (UCI/SEC)
73.. APPLICABLE GAS LIMIT 1.889E 01 tJA 7C.% PART + I-121 LIMIT 1.098E-01 NA S.

ISOTOPES RELEASED (CI)

PARTICULATES CS-127 2.558E-06 0.000E-01 0.000E-01 1.224E-02 BR-140 0.000E-01 0.000E-01 0.000E-01 0.000E-01

!.A-140 0.000E-01 0.000E-01 0.000E-01 0.000E-01 SR-90 0.000E-01 0.000E-01 0.000E-01 1.216E-07 C5-124 2.877E-06 0.000E-01 0.000E-01 2.040E-05 SR-89 7.169E-12 7,169E-12 7.169E-12 2.528E-05 HALOGEtJS I-121 8.789E-05 5.192E-06 5.980E-06 2.185E-02 I-123 0.000E-01 0.000E-01 0.000E-01 4.541E-06 1-125 0.000E-01 0.000E-01 0.000E-01 0.000E-01 GASES KR-85 O.000E-01 0.000E-01 2.206.E 01 2.259E 01 XE-122 6.711E 01 0.000E-01 9.626E 02 5.029E O2 KR-88 0.(00E-01 0.GOOE-01 1.849E 00 8.425E 01 KR-87 0.000E-01 0.000E-01 1.148E 00 1.148E 00 KR-85M 0.000E-01 0.000E-01 1.462E 00 1.119E 01 XE-128 0.000E-01 0.000E-01 0.000E-01 6.072E-04 XE-122M 0.000E-01 0.000E-01 5.615E 00 9.274E 00 ME-125 O.000E-01 0.000E-01 1.422E 01 6.929E 02 RR-41 0.000E-01 0.r00E-01 4.241E 00 4.757E 00 OTHERS XE-121M 0.000 0.000 12.2 1.S72E 02 XE-125M 0.000 C.000

0. 242
0. 242 F-18 0.000 0.000 0.000 0.000

BE-7 0.000 0.00u O.000 3.129E-06 K-40 0.000 0.000 0.000 2.284E-07 CR-51 0.000 0.000 0.000 5.015E-06 tit J-54 0.000 0.000

0. 000
0. 000 CO-57 0.000 0.000 0.000 4.246E-05 CO-58 1.068E-06 4.024E-07 0.000 2.207E-04 FE-59 0.000 0.000 0.000 0.000 CO-60 2.948E-06 0.000 0 000 1.296E-05 flI-65 O.000 0.000 0.000 0.000 Zil-65 O.000 0.000 0.000 0.000 SE-75 0.000 0.000 0.000 0.000 SR-85 O.000 0.000 0.000 1.228E-09 Y-88 0.000 0.000
0. 000 2.667E-06 IIB-94 0.000 0.000 0.000 0.000 t18-95 O.000
0. 000
0. 000 0.000 ZR-95 0.000 0.000 0.000 1.014E-06 RU-102 0.000
0. 000
0. 000 2.252E-07 RU-106 0.000 0.000 0.000 0.000 CD-109 0.000 0.000 0.000 0.000 AG-110t1 0.000 0.000 0.000 3.827E-06 5tt-112 0.000 0.000
0. 000 1.242E-07 CD-112M 0.000 0.000 0.000 0.000 58-125 0.000 0.000 0.000 0.000 BR-123 0.000 0.000 0.000 0.000 C5-126 0.000 0.000 0.000 2.285E-07 CE-129 0.000 0.000 0.000 0.000 CE-144 0.000 0.000 0.000 0.000 EU-152 0.000 0.000 0.000 0.000 HG-202 0.000 0.000 0.000 6.675E-07 U-235 0.000 0.000 0.000 0.000 RA-226 0.000 0.000 0.000 2.020E-06 58-124 0.000 0.000 0.000 0.000 TH-228 0.000 0.000 0.000 0.000 tJR-24 0.000 0.000 0.000
0. 000 til4-56 0.000 0.000
0. 000 0.000 CU-64
0. 000 0.~000 0.000 0.000 BR-84 0.000 0.000 0.000
0. 000 RE.-88 0.000 0.000 0.000 1.08TE-04 RB-89 0.000 0.000 0.000 0.000 MO-99 0.000 0.000 0.000 0.000 SR-91 0.000 0.000 0.000 0.000 Y-91M 0.000 0.000 0.000 0.000 SR-92 0.000 0.000 0.000 0.000 Y-92 0.000 0.000 0.000 0.000 f48-97 0.000 0.000 0.000 0.000 ZR-97 0.000 0.000 0.000 0.000 PB-212 0.000 0.000 0.000 0.000 TC-99M O.000 0.000 0.000 0.000 5B-122 0.000 0.000 0.000 0.000 I-122 0.000
0. 000
0. 600 0.000 I-124 0.000 0.000 0

00 0.000 C5-128 0.000 0.000 0.000 0.000 88-129 0.000 0.000 0.000 0.000 H-187 0.000

0. 000 0.000 0.000 BI-214 0.000 0.000 0.000 9.859E-06 PB-214 0.000 0.000 0.000 0.000 t1P-229 0 000 0.000 0.000 0.000 0.000 0.000 0.000 TE-122 000

Im***c:***************************************+.****************************

RRKPASAS POWER AND LIGHT COMPANY ARKAtlSAS t1UCLEAR ONE, Ut1IT ONE REPORT ON RADIOACTIVE LIQUID EFFLUEt1TS APPENDI".

"A" DOCKET 50-313 YEAR: 1978

        • )**********************************************************************

.-------------- ----~

PEPORTING PARAt1ETERS

/UtJITS /

JUL

/

AUG

/

SEP

/QTRLY TOT /SEf1I TO

=======::==u===========_==_=======================================-==.==--

I I

I I

I I

1.

GROSS BETA + gat 1MA I I

I I

I I

A. TOTAL RELEASED ICURIESI O.20 I O. 13 I O.71 I

1. 1 I

B. AVE CON RELEASED IUCI/t1LI 1.47E-09I 1.33E-09I 5.52E-091 2.27E-09I C. MAX CON RELEASED IUCI/t1LI 6.90E-09I 1.63E-09I 2.79E-09I NR I

I I

I I

I I

2.

TPITIUM I

I I

I I

I A. TOTAL RELEASED ICURIESI 72.

I 41.

I 40.

I 1.52E O2I B. AVE COrl RELEASED IUCI/MLI 5.35E-071 3.OSE-07I 3.10E-07I 3.35E-07I I

I I

I I

I 3.

DISS NOBLE GASES I

I I

I I

I A. TOTAL RELEASED ICURIESI O.36 I O. 35 I

4.1 I

5. 3 I

B. AVE CON RELEASED IUCI/MLI 6.39E-09I 2.50E-09I 3.1SE-OSI 1.34E-OSI I

I I

I I

I 4.

GROSS ALPHA I

I I

I I

I A. TOTAL RELEASED ICURIESI 1.31E-02I O.00 I O.00 I 1.31E-02I B. AVE Coil RELEASED IUCI/MLI 9.80E-11I O.00 I O.00 I 3.20E-11I I

I I

I I

I 5.

RADWASTE RELEASED ILITERSI 1.70E 06I S.02E 051 6.09E OSI 3.12E 06I

'I I

I I

I I

6.

DILUTION WATER ILITERSI 1.34E ill 1.34E 111 1.29E 11I 3.97E 11I I

I I

I I

I 7.

ISOTOPE CONC.

ICURIESI I

I I

I AG-110M I

I 1.55E-03I 2.23E-03I 4.20E-03I 7.97E-03I BR-133 I

I O.00 I S.92E-05I O. 00 I S.92E-05I BA-140 I

I O.00 I O.00 I 9.81E-05I 9.81E-05I BE-7 I

I O. 00 I 3.4CE-04I 7.92E-041 1.14E-03I CE-144 I

I O. 00 I O.00 I 9.79E-05I 9.79E-05I CO-57 I

I 3.27E-03I 2.97E-04I 4.24E-04I 1.06E-03I CO-53 I

I 1.89E-02I 4.51E-02I O.16 I O.22 I

CO-60 I

I 4.06E-021 4.05E-021 0.12 I O. 20 I

CR-51 I

I 1.93E-04I 2.39E-031 4.02E-02I 4.2SE-02I CS-134 I

I 4.65E-02I 2.49E-02I O.11 I O.18 I

CS-136 I

I O.00 I O. OG I O. 00 I O. 00 I

CS-137 I

I 7.31E-02I 3.6?E-02I O.17 I O. 23 I

CS-133 I

I O.00 I O. 00 I O.00 I O.00 I

CU-64 I

I O.00 I O.00 I O.00 I O.00 I

EU-152 I

I O.00 I

O. 00 I O.00 I O.00 I

FE-59 I

I 3.61E-04I 2.49E-04I 7.19E-041 1.44h-UJ1 1-131 I

I 9.88E-03I 1.77E-021 8.46E-021 0.11 I

I-132 I

I O.00 I O. 00 I O.00 I 0.00 I

I-133 I

I 9.SSE-07I O.00 I O.00 I 9.8SE-07I 1-134 I

I O.00 I 1.43E-04I O.00 I 1.43E-04I I-135 I

I O.00 I O.00 I O. 00 I O.00 I

LA-140 I

I O 00 I O.00 I 3.55E-04I 3.55E-04I firJ-54 I

I E 18E-03I 5.39F. 03I 1.62E-021 2.SSE-02I titi-56 I

I O.00 I O. 00 I O.00 I O. 00 I

t10 1 I O. 00 I O. 00 I 7.92E-051 7.92E-05I ttA-24 I O. 00 I 2.20E-05I 4.94E-07I 2.25E-05I flB-95 I

I 6.75E-04I 1.44E-03I 5.33E-031 7.44E-03I FJB-97 I

1 C 77C-07I 1.17E-041 1.77E-04I 2.94E-04I flI-65 I

I O. 00 I O.00 I O.00 I O.00 I

FJP-239 I

I O. 00 I O. 00 I O.00 I O.00 I

RU-106 I

I O. 00 I O.00 I O. 00 I. O. 00 I

RU-103 I

I O. 03 I 1.15E-05I 4.28E-041 4.40E-04I SE-75 I

I O.00 I 3.70E-05I 9.09E-05I 1.2SE-04I SR-09 I

I O. 00 I O.00 I O.00 I O.00 I

SR-90 I

I O.00 I O. 00 I 4.64E-041 4.64E-04I SR-91 I

I O.00 I O.00 I O. 00 I O. 00 I

SR-92 I

I 6.15E-06I 1.60E-051 1.05E-041 1.27E-04I L1-187 I

I O.00 I O.00 I O.00 I O. 00 I

2tt-65 I

I O. 00 I 5.51E-051 0.00 I 5.51E-051 ZR-95 I

I 2.69E-04I 4.63E-04I 3.83E-031 4.56E-03I 2R-97 I

I O. 00 I O.00 I O. 00 I O.00 I

KR-05 I

I 7.06E-04I O.00 I O.00 I 7.06E-041 KR-85t1 I

I O.00 I O. 00 I 5.8SE-OSI 5.38E-05I KR-87 I

I O 00 I O.00 I O.00 I O. 00 I

KR-83 I

I O.00 I O.00 I O. 00 I O.00 I

XE-131t1 I

I 6.31E-03I 1.62E-03I 3.77E-021 4.56E-02I XE-133 I

I O.85 I O.34 I

4. 1 I
5. 2 I

XE-132t1 I

I 3.OSE-041 1.40E-03I 1.76E-02I 1.95E-02I XE-135 I

I 2.SSE-04I 2.54E-04I 2.58E-031 3.10E-03I I

I I

I I

I S.

OF LI:11T <DASED I

I

2. O I
1. 8 I
7. 1 I

11.

I Ott 10 CURIES /QTR.>

_===========u====================================================

ret 1 ARKS :

O.00 = ti.D.

SR-09 Af1D SR-90 VALUES FOR QUARTERLY AtJRLYSIS.

Or*************************************************************************

RRKAf1SAS POWER Ar1D LIGHT COMPAtJY ARMAt1SAS flUCLEAR Gt1E, U!1IT OrlE REPORT Ott RADICAP.TIVE LIQUID EFFLUEllTS APPEf3 DIX "A"

DOCKET 50-313 YEAR: 1978

      • o*******.o*******a.***********************************++******************

REPCRTIllG PARAMETERS

/UllITS /

OCT

/

tlO'/

/

DEC

/QTRLY TOT / SEMI TOT

==

I I

I I

I I

1.

GROSS BETA +. GAMMA I I

I I

I I

A. TOTAL RELEASED ICURIESI O.36 I O.55 I

1. 5 I
2. 5 I
3. 5
8. AVE COfl RELEASED IUCI/MLI 2. 72E-09I 5. 42E-09I 1.17E-081 6. 85E-091 4.39E-O C. MAX COtt RELEASED IUCI/MLI 2.49E-07I 8.14E-091 2.03E-081 flR I

ilA I

I I

I I

I 2.

TRITIUM I

I I

I I

I A. TOTAL RELEASED ICURIESI 27.

I 41.

I 17.

I SS.

I 2.38E O B. AVE COli RELEASED IUCI/MLI 2.08E-07I 4.03E-07I 1.29E-07I

2. 33E-071 3.12E-I I

I I

I I

3.

DISS t10 ELE GASES I

I I

I I

I A. TOTAL RELEASED ICURIESI

1. 0 I O. 57 I

32.

I 33.

I 38.

B. AVE COtt RELEASED IUCI/MLI 7.95E-09I 5.65E-09I 2.39E-071 9.04E-OSI

4. 99 E-O I

I I

I I

I 4.

GROSS ALPHA I

I I

I I

I A. TOTAL RELEASED ICURIESI O.00 I 9.50E-051 0.00 I 9.50E-05I 1.32E-T B. AVE COfl RELEASED IUCI/MLI O.00 I 9.40E-13I O. 00 I 2.60E-131 1.60E-1 I

i I

I I

I 5.

RADWASTE RELEASED ILITERSI 7.49E OSI 1.71E 06I 1.71E 06I 4.1?E 06I 7.29E I

I I

I I

I 6.

DILUTIOri WATER

.ILITERSI 1.32E ill 1.01E 11I 1.22E 11I 3.65E all 7.62E d I

I I

I I

I 7.

ISOTOPE cot 1C.

ICURIESI I

I I

I AG-110M I

I 7.49E-04I 5.53E-041 3.24E-03I 4.54E-03I 1.25E-BR-133 I

I O.00 I O.00 I O.00 I O.00 I 8.92E-BR-140 I

I O.00 I O.00 I O. 00 I O.00 I 9.81E-C BE-7 I

I O.00 I 3.52E-03I O.00 I 3.52E-03I 4.66E-CE-144 I

I O.00 I O.00 I 1.18E-04I 1.10E-04I 2.15E-C CO-57 I

I 4.82E-05I 9.16E-05I 1.46E-03I 1.60E-03I 2.66E-C CO-58 I

I 2.44E-02I 6.68E-02I O.86 I O. 95

'I

1. 2 CO-60 I

I 1.15E-02I 5.08E-021 0.19 I O.26 I O.46 CR-51 I

I 5.06E-03I 1.77E-021 0.24 I O.26 I O.30 CS-134 I 9.5CE-021 7.76E-02I 3.88E-021 0.21 I O. 39 CS-136 I

I 1.81E-04I O.00 I O.00 I 1.81E-04I 1.81E-CS-127 I

I O.15 I O.11 I 5.71E-02I O.32 I O.60 CS-138 I

I O.00 I 1.66E-041 2.34E-04I 4.OOE-041 4.OOE-CU-64 I

I O.00 I O.00 I O.00 I O.00 I O.00 EU-152 I

I O.00 I O.00 I 7.82E-06I 7.82E-06I 7.82E-FE-C9 I

I 6.25E-051 3.10E-04I 2.78E-03I 3.15E-03I 4.48E-I-131 I

I 7.07E-021 0.20 1 9.81E-021 0.37 I O.48

I-132 I

I O. 00 I O. 00 I 3.48E-051 3.48E-051 3.48E-0 1-133 I

I 2.04E-05I 5.84E-03I 2.28E-03I 8.14E-03I 8.14E I-134 I

I O.00 I O. 00 I O.00 I O.00 I 1.43E-O I-135 I

I 0. 00 I O. 00 I O.00 I 0.00 I 0.00 LA-140 I

I O.00 I O. 00 I 4.02E-041 4.02E-04I 7.57E-0 tift-54 I

I 1.40E-03I 6.44E-03I 1.94E-021 2.72E-02I 5.30E-0 11tt-56 I

I O. 00 I O.00 I O. 00 I O. 00 I 0. 00 (10-99 I

I O.00 I O.00 I 1.84E-021 1.84E-03I 1.91E-O flA-24 I

I 5.29E-05I 1.37E-04I 6.34E-05I 2.54E-04I 2.76E-O flB-95 I

I 6.81E-041 1.63E-03I 1. 56E-021 1. 79E-02I 2. 53E-0 118-97 I

I O.00 I 9.11E-05I 1.62E-05I 1.07E-04I 4.02E-O flI-65 I

I O. 00 I O.00 I O. 00 I 0.00 I 0.00 IJP-239 I

I 3.51E-06I 1.34E-04I 1.28E-03I 1.42E-03I 1.42E-0 RU-106 I

I O. 00 I O.00 I O.00 I O. 00 I O. 00 RU-103 I

I 4.79E-06I 1.63E-04I 2.55E-03I 2.72E-03I 3.15E-O SE-75 I

I 3.02E-05I 6.15E-05I 2.46E-051 1.16E-04Z 2.44E-0 SR-89 I

I O.00 I O.00 1 8.34E-041 8.34E-04I 8.34E-O SR-90 I

I O.00 I O.00 I O.00 1 0.00 I 4.64E-0 SR-91 I

I O.00 I O.00 I O.00 I 0. 00 I 0. 00 SR-92 I

I 2.71E-06I 4.39E-051 5.43E-05I 1.01E-04I 2.28E-0 W-187 I

I O.00 I O 00 I 0.00 1 3. 00 I O. 00 2ti-65 I

I O.00 I O.00 I 2.52E-04I 3.52E-04I 4.07E-0 ZR-95 I

I 2.13E-04I 1.25E-03I 1.12E-021 1.27E-02I 1.'72E-0 2R-97 I

I 2.215-051 0.00 T 7.30E-05I 9.51E-051 9.51E-0 KR-85 I

I O.00 I O.00 I O.00 I O. 00 I 7.06E-O KR-85t1 I

I O. 00 I O. 00 1 1.51E-031 1.51E-03I 1.57E-0 KR-87 I

I O.00 I O.00 I O.00 I 0. 00 I 0.00 KR-GO I

I O.00 I O. 00 I 2.20E-04I 2.20E-04I 2.20E-0

><E-131M I

I 2.47E-03I 4.67E-031 5.10E-02I 5.81E-021 0.10

)(E-133 I

I

1. O I O. 56 I

31.

I 33.

I 38.

)(E-3 33t1 I

I 1.85E-03I 2.23E-03I 0. 22 I O.23 I O.24 XE--135 I

I 9.43E-04I 3.05E-031 5.12E-021 5.52E-02I 5.83E-0 I

I I

I I

I S.

% OF lit 1IT (BASED I

I

3. 6 I
5. 5 I

15.

I

.25.

I Oil 10 CURIES /QTR.>

=============..======_=============================================

REl1RRKS:

O.00 = ti.D.

SR-89 AtlD SR-90 VALUES FOR QUARTERLY AtlRLYSIS.

I:Ri; I L I T'r'--- ANO Ut 4 [ T 't J'

PEPORT OF RHDIURCTIVE GR$ EFFLULt!T :.

DOCT:ET 50-21::

f-OR t h ill-ll.; UF 'i ERPit17.' -

FNOTE: TOT"EI~HER SEMI 3.5T PALF.- OP Ar.!r20AL ' :t40 HALF) TOTALS FELEASE5 JUL AUG EEP TOT

1. GASES (CI?

0.000E-01 0.000E-01 0.000E-01 0.000E-01

2. HALOGEN'.

O.000E-01 0.000E-01 0.000E-01 0.000E-01 (CI) 4.H-2(CI)

O.000E-01 0.000E-01 0.000E-01 0.000E-01

5. ALPHA <CI>

r, r$c40E-01 NR

6. MAXIMUM GA5 0.000E-01 0.000E-01 0.000E-01 NA RELEASE RATE (UCI,' SECT 7R. *: APPLICABLE GA5 LIMIT 0.000E-01 fJA' 7C. *: PART + I-121 LIMIT 0.000E-01 NR 8.

ISOTOPES RELEASEO(CI>

PAPTICUI. ATE 5 C5-12?

ti. 000E-01 0.00nE-01 0.000E-01 0.000E-01 B A-14 0 0.UOOE-01 h C'iaur-01 0.000E-01 0.000E-01 LA-140 U.000E-01 0.000E-01 n nora --,,.

n onOE-01 SP-90 0.000E-01 0 000E-01 0.UOOE-ul 0.000".-01 C5-124 0.000E-01 0.000E-01 0.OOOE-01 0.000E-91 5R-89 0.000E-01 0.000E-01 0.000E-e1 2.148E-08 HALOGENS T-121 0.000E-01 0.000E-01 0.000E-01 0 000E-01 I-122 0.OE0E-01 0.000E-01 0.000E-el 0.000E-01 1-125 O.000E-01 0.000E-01 0.000E-01 0.OOOE-01 GA5E5 VR-85 O.000E-01 0.UOOE-01

0. 000E -01 0.000E-01 l:E-122
0. 000E -01 0.000E-01 0.000E-el 0.000E-01 UR-88 0 000E-0t 0 000E-01 0.00 d-01 0.000E-01
': 87 o v00E-0i 0.000E-01 0.uOcy-01 0.Oe0E-01 I;P-85M O.000E-OL 0.000E-01 0.00vt_-vi 0.000E-01 XE-128 0.000E-ul 0.000E-01 0.000E-01 0.000E-01 SE-t22M U On0E-01 0.OO0E-01 0.000E-01 0.OOOE-01

'E-125 n on0E-U!

u.000E-01 0 OiioE-01 0.000E-01 RR-4L o noi'E-U1 0.U00E-01 0.eUUE-01 0.000E-01 OTHERS P.E-121M

0. 000 0.000
0. u u.,

O.000 c

PE-12 5t 1

0. 000
0. vou 0 000
0. 000 F-18 U. Oig0 0.000
0. 000 0.000

BE-7 0 OOn

" No i

o. vuu O. 000 K-40 O. 000 O. 000 0.000 O.090 CP-51.

O. 000

0. 000
0. 000 0.000 fir!-Sq
0. 000 0.000
0. 000 0.000 CO-57
0. 00U 0.000 U. 000
0. 000 CO-58 U. 000
0. 000
0. 000
0. 000 FE-59 0.000
0. 000 O. 000
0. 000 CO-60 0.000
0. 000
0. 000
0. 000 111 - 6 5 O. 000 0.000
0. 000 0.000 It t-6".

O. i.00

0. 000 0.000
0. 000 SE-75 O.000
v. 000
0. 000 0.000 SP-85 0.000
0. eOO 0.UOO 0.000 Y-88 0.000 0.000 0.000 0.000 t18-94 0.000 0.000 0.000 0.000 tJ8-95 O.000
0. 000
0. 000
0. 000 2R-95 0.000 0.000 0.000
0. 000 RU-102 0.000 0.000
0. 000 0.000 PU-106 0 000 0.000
0. 000 0.000 CD-109 0.000 U. 000 0.000 0.000 AG-110M 0.000 0.000
0. 000 0.000 Sti-112 0.000 0.000
0. 000 0.000 CD-112M 0.000 0.000 0.000 0.000 58-125 O.000
0. 000 0.000
0. 000 BR-122 0.000 0.000 0.000
0. 000 CS-126 0.000 0.000 0.000 0.000 CE-129 0.000 0.000 0.000 0.000 CE-144
0. 0l$0 0.000
0. UOO
0. 000 EU-159 i- ~JU 0.000
0. 000 0.000 HG-202 0.000
0. 000 0.000
0. 000 U-225 O. 000
0. 000
0. 000 0.000 PA-226 0.000 0.000 0.000 0.000 SB-124 0.000 0.000 0.000 0.000 TH-228 0.000
0. 000 0.000
0. 000 f!A-24 0.000 0 000 0.000 0.000 Mil-56 0.000 0.000
0. 000 0.000 CU-64
9. 000
0. 000
0. 000 0.000 BR-84 0.000
0. 000 0 000 0.000 PC-OS 0.000
0. UGO G 000
0. 000 P8-89 0.000
0. 000
0. Ouo 0.000 MO-99 0.000 0.000
0. 000
0. 000 SR-91
0. 000
0. OUU
0. 000 0.000 Y-91M 0.000 0.000
0. 000 0.000 SR-92 0.000 0.000 v.000 0 000 Y-92
0. 000 0.000 v.000 0.000 r18-97 0.000 0.000 0 000 0.000 2R-97 0.000 0.000 n rinn O.000 P8-212 0 000
0. 000
0. 000
0. 000 TC-99M O. 000 0.000
0. 000
0. 000 58-122 0.000
0. 00U
0. 000 0.000 I-122 0.000 0.000
0. 000
0. 000 I-104 0.000 0.000 0.000 0.000 CS-128 0.000
0. 000
0. 000
0. U00 BA-129 O.000
0. 000
0. 000 0.000 N-187
0. UOO O. 000
v. 000 0.000 8I-214
0. 000
0. 000
0. 000
0. 000 P8-214 0.000
0. 00i.i 0.000 0.000 tJP-229
0. 000 0.000
0. U00 0.000 TE-122
0. 000
0. 000
0. 000 0.000

RELEA?ES i.u/ I NOV DEC TOT

1. GASES /.CI' O.000E-01
0. Oi_'UE-01 0 ih>E-01 0.U00E-01
2. HALOGEN 5
0. U000-01
0. 0 0 0 E - 0.1 U Eu;UE-01 0.000E-01 (CI) 4.H-2/.CI)

O.000E-01 0.000E-01 0.UO0E-01 0.000E-01

5. ALPHA /.CI)

O.OUUE-01 MR

6. MAXIMUM GAS 0.000E-01 0.000E-01 0.COOE-01 NA RELEASE RATE <.UCl.'::EC >

7A.:: APPLIC ABLE GH5 LIMIT O.000E-01 NR 7C.M PART + I-13.1 LIMIT 0.000E-01 NR 8.

ISOT0FES RELE ASEE i.CI)

PARTICULATES C5-127 0.000E-01 9.000E-01 0.000E-01 0.000E-01 BR-140 0.000E-01 0.OOOE-01 0.000E-01 0.000E-01 LA-140 0.000E-01

0. UOOE-01.

O.000E-01 0.000E-01 Sr, '; 0 0.OUOE-01 0.000E-01 0.OOOE-01 0.000E-01 f.5-124 0.000E-01 0 000E-01 0.000E-01 0.000E-01

0. 000E--01 0.000E-01 0.000E-01 0.OOGE-01 1-12 0.000E-01 0.000E-01 0.UOOE-01 0.000E-01 1-125 0.000E-01 0.000E-01 0.000E-01 0.000E-01 GASES KR--85 O. 000E--01 0.000E-01 0.000E-01 0.OOGE-01 F.E -122 0.000E-01 0.000E-01 0.000E-01 0.000E-01 KR-88 0.000F-01 9.000E-01 O 000E-ul O.000E-01 KR-87 0.000E-01 0.000E-01 0.000E-01 0.000E-01 1:R-85M O.000E-01 9.000E-01

.0.000E-01 0.000E-01 l:E-128

0. 000E--01 0.000E-Oi 0.UO0E-01 0.000E-01 ME-122M O 000E-01 0.000E-01 0.000E-01 0.000E-01 XE-125 O.000E-n1 0 000E-01 0.OUGE-01 0.000E-01 AR-41 0.OUOE--01
0. 0 0 0 E - e.t.

O. OU0E-U.1 0.000E-01 OTHERS ME-121M O.000 0.000

0. 000 0.~000 SE-13 5M 0.000 0 000
0. 000 0.000 F-18 0 t 'no
n. U00 n nun O.U00

BE-7

0. 000 0.000
0. 000
9. 000 V.-40
0. 000 0.000
0. 000
0. 000 CR-51
0. 000 9.U00
0. 00u O. 000 MN-54
c. OOu O.000
0. 000
0. 000 CO-57 0 000 9.000 9.000 0.000 CO-59 0 000 O. 000
0. 000 O. 000 FE-59
0. 000 0.000 0.000 O. 000 CO-60 0.000 O.000
0. u00 O.000 NI-65 O. 000 9.000
0. 000
0. 000 IN-65 O. Ou0
0. 000 0.000 0.000 SE-75 O. 000
0. 000 0.000 0.000 SP-85 U.000
0. 000 0.000
0. 000 Y-89 O.000 0.000
0. 000
0. 000 NB-94 0.000 0.000 0 000 9.000 NB-95 O. 000 0.000
0. 000 0.000 2R-95 O. 000 0.000 O.000 O. 000 RU-102 0.000 0.000 0.000 0.000 RU-106 0.000 0.000 0.000 0.000 CD-109 0.000 0.000
0. 000 0.000 AG-110M 0.000
0. 000 0.000 O. 000 SH-112
0. 000
0. 000 0.000 0.000 CD-112M O.000 0.000 0.000
0. 000 58-125 O.000 0.000
9. 000 0:000 BR-122
0. 000
0. 000 0.000 0.000 CS-126 0.000 0.000 o ruso 0.000 CE-129 O.000 0.000 0.000 O.000 CE-144 0.000 0.000
0. 000 O 000 EU-152 C 000 0.000 0.000 0.000 HG-202
0. Guu O 000 0.000
0. 000 U-225 f.i 000 0.000 0.000 O. 000 RA-226
v. 000 0.000 0.000 0.000 58-:124 0 000 0.000 ri. 0 0 0
c. 000 TH-228 O. 000 O. GOO O 000 O.000 flA-24
0. 00u 0.000 O.000 0.000 MM-56 0.000
0. Ono n 600
0. 000 CU-6:

O.000 0.000 0.000

0. 000 BR-84 0.000 0.000
0. 000 9.000 RB-98 0.000
0. 000 0.000
0. 000 RB-89 0.000 0.000 0.000 0.000 MO-99 0.000
0. 000 O.000 0.000 SR-91 0.000 0.000 0.000 0.000 Y-91M 0.000
0. 000 0.000 0.000 SP-92 0.000 0.000 0.000 0.000 Y-92 0.000
0. 000 0.000
0. 000 NB-97 O.000 0.000 0.000 0.000 2P-97 0.000 0.000 0.000 O.000 PB-212
0. 000
0. 000 0.000
0. 000 TC-99M o 000 0.000 0.000 0.000 58-122
0. 000 O.000
0. 00u 0.000 I-122 O.000 0.000 0.000 0.000 I-124 0.000 0.000 0.000
0. 000 CS-128 0.000 0 000 0.000 0.000 BR-129 0.000 0.000 0 U00 0.000 M-107 0.000
0. Ora.)

O. 000 0.000

'81-214 0.000 0.000

0. 000
0. 000 PB-214 0.000 0.000 0.000 0.000 NP-229 0.000 0.000 0.000
0. 000 TE-122 0.000 0.000 0.000 0.000

$. u... u + n u t + + + 4. * + * *

  • u * * * * * * + o * * * * * * + + + +
  • u * * * * * * * * * * * * * * * * * * * * * * * * *
  • u * **

ARKANSA5 POWER ArlD LIGHT COMPAtlY ARKAtl5AS tlVCLEAR OrtE, UrtIT TWO PEPORT Ort RADI0 ACTIVE LIQUID EFFLUEllTS APPENDD'. " A" DOCKET 50-168 YEAR-1978 4**u********.******4***************4:*****************************9*********

REPORTING PARAMETERS

/ UNITS /

OCT

/

tlOV

/

DEC

/QTRLY TOT / SEMI TOT

==

I I

I I

I I

1.

GROS 5 EETA + GAMMA I I

I I

I I

A. TOTAL RELEASED ICURIESI 0.00 I 0.00 I 8.08E-02I 8.0SE-02I S.08E-O B. AVE C0tt RELEASED IUCI/MLI 0.'00 I 0.00 I 6.12E-11I 2.21E-11I 1.06E-1 C.MA*/. COtl RELEA5ED IlCI/MLI 0.00 I 0.00 I 5.24E-111 NA I

NA.

3 I

I I

I I

I 2.

TRITIUM I

I I

I I

I A. TOTAL RELEA5ED ICURIESI 0.00 I O. 00 I 4.42E-021 4.42E-021 4.42E-O

8. AVE Coil RELEASED IUCI/MLI O. 00 I 0.00 I 3.25E-101 1. 22E-1GI 5. 80E-1 I

I I

I I

I 2.

DISS F10BLE GA5ES I

I I

I I

I A. TOTAL RELEASED ICURIESI 0.00 I O.00 I 1.66E-02I 1.66.E-02I 1.66E-O B. AVE Cort RELEASED IUCI/MLI 0.00 1 0.00 1 1.26E-111 4.5"E-12I 2.1SE-1~

I I

I I

I I

4.

GROSS ALPHA I

I I

I I

I R. TOTAL RELEASED ICURIESI O. 00 1 0.00 I 0. 00 I 0. 00 1 0.00

8. AVE Cort RELEASED IUCI/MLI O.00 I 0.00 I 0.00 I 0.00 I 0. 00 I

I I

I I

I 5.

RADWASTE RELEASED ILITERSI 0. 00 I 0. 00 I 1.22E 06I 1.22E 06I 1.22E O

.I I

I I

I I

6.

DILUTIO!! WATER ILITERSI 1.22E ill 1.01E 11I 1.22E ill 3.65E 111 7.62E 1 I

I I

I I

I 7.

ISOTOPE C0 tlc.

ICURIESI I

I I

I AG-110M I

I 0.00 1 0.00 I 0.00 I O.00 I 0. 00 BA-123 I

I 0.00 I 0.00 I O.00 I O-^0 I 0.00 BA-140 I

I 0.00 I O. 00 I 0. 00 I O. 'tO I 0. 00 EF.-7 I

I 0.00 I 0.00 I 0. 00 I 0. ' A I 0. 00 CE-144 I

I 0.00 I 0.00 I O. 00 I O. M I 0. 00 CO-57 I

I 0.00 I 0.00 1 0.00 I 0. 00 I O.00 CO-58 I

I 0.00 I 0.00 I 1.80E-03I 1.80E-021 1.SOE-0 CO-60 I

I O.00 I 0.00 I 6.77E-05I 6.77E-05I 6.77E-0 CR-51 I

I 0.00 I 0.00 1 0.00 I O. 00 I O. 00 C5-124 I

I 0.00 1 0.00 I 0. 00 I 0.00 1 0.00 CS-126 I

I G. 00 I 0.00 I 0. 00 I O.00 I O.00 CS-127 I

I 0.00 I 0.00 1 1.96E-051 1.96E-051 1.96E-C C5-128 I

I 0.00 I 0.00 I 0. 00 1 0. 00 1 0.00 CU-64 I

I O.00 I 0.00 I 0. 00 I O.00 1 0.00 EU-152 I

I 0.00 1000 1 0.00 I 0. 00 I O.00 FE-59 I

I 0.00 I 0.00 1 0, 00 1 0.00 1 0. 00 I-121 I

I O. 00 1 0.00 1 7.59E-041 7.59E-04I 7.59E ~

I-122 I

I 0.00 I O. 00 I 0.00 I O. 00 I 0.00 I-123 I

I O. 00 '

I 0.00 I S.85E-041 8.65E-041 8.85E ~

I-124 I

I 0. 00 I O.00 I 0. 00 I 0. 00 I

O. 00 1-135 I

I 0.00 1 0.00 1 1.14E-04I 1.14E-04I 1.14E ~

LA-140 I

I O.00 I 0.00 1 0.00 I 0.00 I O. 00 Mil-54 I

I 0. 00 I O. 00 I 9.86E-051 9.86E-05I 9.86E-05 Mti-56 I

I 0. 00 I 0. 00 I 0. 00 I 0.00 I O. 00 MO-99 I

I O.00 I O. 00 I 5.70E-05I 5.70E-051 5.70E-05 t4R-24 I

I 0. 00 I 0. 00 I 4.22E-02I 4.22E-02I 4.22E-02 tJB-95 I

I O.00 I O. 00 I 0.00 I 0.00 I O. 00 tJB-97 I

I 0.00 I O.00 I O. 00 I 0.00 I O. 00 f41-65 I

I 0.00 I O.00 I O.00 I O.00 I O.00 tJP-239 I

I O.00 1 0.00 I O.00 I 0.00 I 0.00 RU-106 I

I 0.00 I O. 00 I O.00 I O.00 I O.00 RU-102 I

I O.00 I O. 00 1 0.00 I O. 00 I O.00 SE-75 I

I 0.00 I 0.00 1 0.00 I 0.00 1 0.00 SR-89 I

I O.00 1 0.00 I 6.02E-05I 6.02E-05I 6.02E-O SR-90 I

I 0.00 I O.00 I O. r:0 I 0.00 I 0.00 SR-91 I

I 0.00 I O. 00 I O. 00 I O.00 I 0.00 SR-92 I

I 0.00 I O.00 I O. 00 I O.00 I 0.00 H-187 I

I 0.00 I O. 00 I O. 00 I O. 00 I 0.00 211-65 I

I O.00 I O.00 I O. 00 I 0.00 I 0.00 ZR-95 I

I O.00 I O. 00 1 0.00 I O. 00 I 0.00 2R-97 I

I 0.00 1 0.00 I O. 00 I 0.00 I 0.00 KR-85 I

I 0.00 I O.00 I O. 00 1 0.00 I O.00 KR-85M I

I 0. 00 I 0. 00 I O. 00 I 0.00 I O. 00 KR-87 I

I 0.00 I O. 00 I 0. GO I 0.00 I O.00 KR-88 I

I O. 00 I O.00 I O.00 I O.00 I 0.00 XE-121H I

I O.00 I 0. 00 1 0.00 I O. 00 I O.00 XE-122 I

I O.00 I 0. 00 1 1.54E-021 1.54E-02I 1.54E-0 XE-122M I

I O.00 I O.00 I O. 00 I 0.00 I 0.00 XE-125 I

I 0.00 I O.00 I 1.17E-041 1.17E-04I 1.17E-0 I

I I

I I

I 8.

  • OF LIMIT (BASED I

I O.00 I 0. 00 I 8.08E-02I 8.08E-021 Ori 10 CURIES /QTR.>

=================_================================================

REMARKS:

O.00 = ti.D.

SR-89 Rf4D SR-90 VALUES FOR QUARTERLY 6tlALYSIS.

75 Paae B 3/4 1-4 The revised CEA drop time limit of 3.1 seconds is included in Bases Section 3/4.1.3.

Page B 3/4 2-1 Bases section 3/4.2.1 is revised to include separate uncertainty factors for load-follow and non-load-follow operation.