Text
t
.
.
[g* "I%gk
NUCLEAR REGULATORY COMMISSION
UNITED STATES
REGloN 11
2
) f,
6
0
- ~'-
-E
101 M ARIETTA sTR EET, N.W.
ATLANTA, GEORGIA 30303
o,
'.....*
DEC 2 01978
In Reply Refer To:
RII:RHW
50-160/78-5
Georgia Institute of Technology
School of Nuclear Engineering
Atta: Dr. L. E. Weaver, Director
225 North Avenue
Atlanta, Georgia 30332
Gentlemen:
This refers to the inspection conducted by Mr. R. H. Wessman of this office
on November 29 - December 1,
1978, of activities authorized by NRC License
No. R-97 for the Georgia Institute of Technology Research Reactor facility,
and to the discussion of our findings held with Dr. M. V. Davis at the
conclusion of the inspection.
The inspection was an examination of the activities conducted under your
license as they relate to radiation safety and to compliance with the
Commission's rules and regulations and the conditions of your license. The
inspection consisted of selective examinations of procedures and representa-
tive records, interviews with personnel, and observations by the inspector.
Areas examined during the inspection and our findings are discussed in the
enclosed inspection report. Within these areas, the inspection consisted of
selective examinations of procedures and representative records, interviews
with personnel, and observations by the inspector.
We have examined actions you have taken with regard to previously identified
enforcement matters and unresolved items. The status of these items is dis-
cussed in the enclosed report.
During the inspection, it was found that certain activities under your license
appear to be in noncompliance with NRC requirements. These items and references
to pertinent requirements are listed in the Notice of Violation enclosed
herewith as Appendix A.
This notice is sent to you pursuant to the provisions
of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Ccde of
Federal Regulations.
Section 2.201 requires you to submit to this office,
within 20 days of your receipt of this notice, a written statement or
explanation in reply including:
(1) corrective steps which have been taken
by you and the results achieved; (2) corrective steps which will be taken to
avoid further noncompliance; and (3) the date when full compliance will be
achieved.
79011800 M
9
.
Georgia Institute of Technology
-2-
DEL 2 0 578
In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,
Title 10, Code of Federal Regulations, a copy of this letter and the enclosed
inspection report will be placed in the NRC's Public Document Room. If this
report contains any information that you (or your contractor) believe to be
proprietary, it is necessary that you make a written application within 20 days
to this office to withhold such information from public disclosure. Any such
application must include a full statement of the reasons on the basis of which
it is claimed that the information is proprietary, and should be prepared so that
proprietary information identified in the application is contained in a separate
part of the document.
If we do not hear from you in this regard within the
specified period, the report will to placed in the Public Document Room.
Should you have any questions concerning this letter, we will be glad to
discuss them with you.
Sincerely,
C
-
F. J. Long, Chief
Reactor Operations and Nuclear
Support Branch
Enclosures:
1.
Appendix A, Notice of Violation
2.
Inspection Report No. 50-160/78-5
cc w/ encl:
Dr. Thomas E. Stelson
Vice President For Research
Georgia Institute of Technology
225 North Avenue
Atlanta, Georgia 30332
Dr. M. V. Davis, Director
Nuclear Research Center
Georgia Institute of Technology
225 North Avenue
Atlanta, Georgia 30332