Text
.
.
.
O
UNITED sT ATEs
pn neG
NUCLE AR REGULATORY COMMISSION
,o,,
,
'
REGloN 11
"
t
o
)
(
5
$
101 M ARIETT A STREET,N.W.
'
I
ATLANTA, GEORGIA 30303
o
%*
/
- ...*
DEC 2 21978
In Reply Refer To:
RII:MDH
50-364/78-21
Alabama Power Ccmpaay
ATTN:
Mr. A. R. Barton
Executive Vice President
'
Post Office Box 2641
Birmingham, Alabama 35291
Gentlemen:
This refers to the inspection conducted by Mr. M. D. Hunt of this office
on December 12-14, 1978 of activities authorized by NRC License No.
CPPR-84 for the Joseph M. Farley Plant, Unit 2 facility, and to the
discussion of our findings held with Mr. J. A. Mooney at the conclusion
of the inspection.
Areas examined during the inspection and our findings are discussed in
the enclosed inspection report. Within these areas, the inspection
consisted of selective examinations of procedures and representative
records, interviews with personnel, and observations by the inspector.
We have examined actions you have taxen with regard to previously reported
unresolved items.
The status of these items is discussed in the enclosed
report.
During the inspection it was found that certain activities under your
license appear to be in noncompliance with NRC requirements. This item
and references to pertinent requirements are listed in the Notice of
Violation enclosed herewith as Appendix A.
Corrective actions to prevent
recurrence were completed prior to the conclusion of this inspection;
therefore, a reply is not requested.
In accordance with Section 2.790 of the NRC's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter and
the enclosed inspection report will be placed in the NRC's Public Document
Room.
If this report contains any information that you (or your contrac-
tor) believe to be proprietary, it is necessary that you make a written
application within 20 days to this office to withhold such information
from public disclosure. Any such application must include a full state-
ment of the reasons on the basis of which it is claimed that the informa-
tion is proprietary, and should be prepared so that proprietary informa-
tion identified in the application is contained in a separate part of
the document.
If we do not hear from you in this regard within the
specified period, the report will be placed in the Public Document Room.
790118003(
.
.
.
.
Alaba*ma Power Company
-2-
DEC 2 21978
'.
Should you have any ques.tions er- erning this letter, we will be glad to
discuss them with you.
Sincerely,
,
F
Charles E. M pTy, Chief
Reactor Construction and
Engineering Support Branch
Enclosures:
1.
Appendix A, Notice of Violation
2.
Inspection Report No. 50-364/78-21
cc w/ enclosures:
Mr. R. E. Hollands, Jr. , QA Supervisor
Post Office Box U
Ashford, Alabama 36312