ML19262C613

From kanterella
Jump to navigation Jump to search
Forwards LER 80-012/03L-0
Date released: 10/03/2019 Download: ML19262C613


LER 80-012/03L-0:on 800111,during Surveillance Testing, Emergency Diesel Generator a Tripped on Low Lube Oil Pressure.Caused by Partial Failure of Engine Immersion Heater Resulting in Cold Lube Oil.Heater Replaced
ML19262C614
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/09/1980
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19262C614 (2)
Forwards LER 80-012/03L-0
ML19262C612
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 02/09/1980
From: Leonard J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19262C612 (1)