ML19261F163

From kanterella
Jump to navigation Jump to search
Forwards LER 79-093/03L-0
Date released: 10/02/2019 Download: ML19261F163


LER 79-093/03L-0:on 790924,crack Noted in Casing Drain Line Weld of Makeup Pump MUP-1B.Caused by Cyclic Vibration Fatigue.Line Repaired & Returned to Svc on 791006
ML19261F166
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 10/18/1979
From: Cooper J
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19261F166 (2)
Forwards LER 79-093/03L-0
ML19261F162
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 10/22/1979
From: Stewart W
FLORIDA POWER CORP.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19261F162 (1)