Forwards IE Circular 79-10, Pipefittings Mfg from Unacceptable Matl. No Action Required
ML19261E356
Person / Time
Site: Columbia, Washington Public Power Supply System, Satsop  
Issue date: 06/26/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Strand N
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
References
NUDOCS 7907060226
Download: ML19261E356 (1)


Text

p HRECp o,

UNITED STATES e

NUCLEAR REGULATORY COMMISSION M

[ \\[g..

.p'g('h vh. g REGION V 1990 N. CALIFORNI A EsudLEVARD S fu 4,

%, ' ' J '

c[q SUITE 702, WALNUT CREEK PLAZ A

  • e,,*

WALNUT CREE K, CALIFORNI A 94596 June 26, 1979 Docket ?!os. a0-460, 50-397 50-508,53-509. 50-313 Washington Public Power Su,-ly System P. O. Box 958 3000 George Washington Way Richland, Washington 99352 Attention:

Mr. fl. O. Strand Managing Director Gentlemen:

This Circular is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities.

Tio specific action or response is requested at this time.

If further tiRC evaluations so indicate, an IE Bulletin will be issued to reco.Tcend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of the appropriate i;RC Regional Office.

Sincerely, l?r fJims, R. H. Engelken Director

Enclosures:

1.

IE Circular fio. 79-10 2.

List of IE Circulars Issued in Last 12 Months cc w/ enclosures:

M. E. Witherspoon, WPPSS A. D. Kohler, WPPSS J. P. Thomas, WPPSS W. J. Talbott, WPPSS G. C. Sorensen, WPPSS m/l 30b M4 L

7907060226 Q

UNITED STATES f;UCLEAR REGULATORY C0yf41SS10f!

0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 June 26, 1979 IE Circular No. 79-10 (7906200171)

PIPEFITTINGS ftANUFACTURED FROP UNACCEPTABLE !1ATERIAL Description of Circumstances:

Liberty Equipment and Supply Company of Kennewick, Washington and Tube Turns Division, Chemetron Corporation of Louisville, Kentucky reported on April 4 and 12, 1979, respectively, that potentially defective pipe fittings were manufactured from naterial with a high carbon content beyond the range allowed by ASTM A-234 WPB. These high carbon content fittings may crack when welded.

Tube Turns received 3.500 OD x.250'.l nipe from U. S. Steel - Lorain -

ider.tified as U. S. Steel Heat flo. N570028.

A total of 28,153 feet was received and identified t y Tube Turns as Lot

/19.

U. S. Steel has not been able to determine the oNact number of lengths af pipe of incorrect chemistry, but indicated it covD be at least four lengths.

From this pipe, 4" - 90 degrees and 45 degrees

.237 wall elbows and 2"

.237 wall straight tees, ASTM A-234 WPB, were produced by Tube Turns.

Each length of pipe is twenty feet and makes from 20 to 30 fittings.

Approximately 27,000 fittings were produced and each is identified by Tube Turns Lot No. W6719.

c.hipment of these fittings started in March of 1978, and it is estimated all were shipped before the end of 1978.

On May 10, 1979, the Tube Turns Division reported to the NRC that 4" elbows.

Lot U6719, have been provided to the nuclear power plants listed below.

U.S.

Steel has tested about one hundred and fifty (150) loose and installed fittings at the seven sites noted by an asterisk.

  • Grand Gulf
  • Zimmer
  • Phipps Bend
  • Waterford III
  • Brown's Ferry Midland Lirerick Shoreham
  • LaSalle Sequoyah
  • Brunswick Hartsvil ;e Bellefonte On June 1, 1979, the Tube Turns Division reported to the NRC via telephone that of the 160 fittings tested at Nuclear Power Plani.s, three (3) pieces were found to hcve a high carbon content and were replaced.

All construction pe "it holders are advised to conduct a review of their pipefitting receiving documents for the period from March 1978 to January 1979 and deternine if fittings manufactured by the Tube Turn Division can be identified as Tube Turn lot W6719.

If shipment of the defective material lot were received, appropriate corrective action should be initiated.

No written response to this circular is required.

If you require additional infornation regarding this subject, contact the Director of the appropriate NRC Regional Office.

2O fliSO Sol 7907020171 4x

/

e IkCircularI;o.79-10 Enclosure June 26, 1979 Page 1 of 2 LISTING OF IE CIRCULARS ISSUED IN LAST TWELVE MONTHS Circular Subject Date Issued To No.

of Issue 78-12 HPCI Turbine Contrcl 6/30/78 All Holders of Valve Lift Rod Bending BUR OLs or cps for plants with HPCI Terry Turbine 78-13 Inoperability of Multiple 7/10/78 All Holders of Service Water Pumps Reactor OLs and cps except for plants located in: AL, AK, CA, FL, GA, LA, MS, SC 7d-14 HPCI Turbine Reversing 7/12/78 All Holders of BWR Chanber Hold Down Bolting OLs or cps for plants with a HPCI Terry Turbine excepting Duane Arnold and Monticello 78-15 Cheskvalves Fail to 7/20/78 All Holders of Close In Vertical Reactor OLs or cps Posi tion 78-16 Limitorque Valve 7/26/78 All Holders of Actuators Reactor OLs or cps 78-17 Inadequate Guard Training /

10/13/78 All Holders of Qualification and Falsified and applicants Training Records for Reactor OLs 78-13 UL Fire Test 11/6/78 All Holdars of Reactor OLs or cps 78-19 Manual Override (Bypass) 12/28/78 All Holders of of Safety Actuation Signals cps 2 '/ l 3bb

a IE Circular No. 79-10 Enclosure Ju'ne 26, 1979 Page 2 of 2 LISTING OF IE CIRCULARS ISSUED IN LAST TWELVE MONTHS Circular Subject Date of Issued to No.

Issue 79-01 Administration of 1/12/79 All Holders of Unauthorized Byproduct Licensees except Material to Humans Teletherapy Medical Licensees and each Radiopharmaceutical Suppliers 79-02 Failure of 120 Volt Vital 2/16/79 All Holders of AC Power Supplies Reactor OLs and cps 79-03 Inadequate Cuard Training-2/23//9 Ali Holders of Qualification and Falsified and applicants Training Records for Special Nuclear Material Licenses lr Safeguards Group I 79-04 Loose Locking Nut 0-3/1C/79 All Holders of Limitorque Valve-Reactor OLs or cps Opera tors 79-05 Moisture Leakage in 3/20/79 All Holders of Stranded Wire C;.Juctors Reactor OLs or cps 79-06 Failure to Use Syringe 4/19/79 All Holders of and Battle Shields in Medical Licensees Nuclear Medicine except teletherapy licensees 79-07 Unexpected Speed Increase 5/2/79 All Holders of of Reactor Recirculation BWR OL's or CP's MG Set Resulted in Reactor Power increase 79-06 Attempted Extortion - Low 5/18/79 All Fuel Facilities Enriched Uranium Licensed by NRC 79-09 Occurrences of Split. or 6/22/79 All Materials Punctured Reguiutor Diaphragms Priority I, Fuel In Certain Self Contained Cycle and Operating Breathing Apparatus Reactor Licensees qei D h pI\\