NU REG-0482 OCCUPATIONAL RADIATION EXPOSURE AT LIGHT WATER COOLED POWER REACTORS Annual Report 1977 2305 033 p coq, e
k e
x..:..i Office of Management and Program Analysis U. S. Nuclear Regulatory Commission 7 90602 06Pf
Available from National Technical Information Service Springfield, Virginia 22161 Price:
Printed Copy $6.00 ; Microfiche $3.00 The price of this document for requesters outside of the North American Continent can be obtained from the National Technical Infonnation Service.
2305 034
NU REG-0482 OCCUPATIONAL RADIATION EXPOSURE AT LIGHT WATER COOLED POWER REACTORS Annual Report 1971 Linda Johnson Peck Manuscript Completed: April 1979 Date Published: May 1979 2305 035 Licensing Operations Evaluation Branch Division of Technical Support Office of Management and Program Analysis U. S. Nuclear Regulatory Commission Washinoton, D.C. 20555
SUMMARY
This report presents an updated compilation of occupational radiation exposures at commercial light water cooled nuclear power reactors (LWRs) for the years 1969 through 1977.
The information contained in this document was derived from reports submitted to the United States Nuclear Regulatory Commission in accordance with requirements of individual plant Technical Specifications, and in accordance with Part 20.407 of Title 10, Chapter 1, Code of Federal Regulations (10 CFR Part 20.407).
An additional 4 LWRs completed a full calendar year of commercial operation for the first time in 1977. This report now encompasses data from 57 commercially operating U.S. nuclear power plants. The number of personnel monitored at LWRs increased approximately 10% in 1977, and the average collective dose to personnel (man-rems per reactor-year) increased 14% over the 1976 average.
The average number of personnel receiving measurable exposure per reactor increased 11%, and the average exposure per individual in 1977 was 0.8 rem per person.
2305 036 iii
TABLE OF CONTENTS
SUMMARY
iii INTRODUCTION 1
PERSONNEL EXPOSURE SUfEARY 5
EXPOSURE TO INDIVIDUALS..............
14 EXPOSURE BY WORK AND JOB FUNCTION.........
17 REFERENCES 24 2305 037 V
_IST OF TABLES Table Page 1.
Man-Rem Summary......................
4 2.
Summary of flan-Rem Per Megawatt-Year at LWRs - 1977...
8 3.
Man-Rem Per Megawatt-Year at BWRs and PWRs - 1977....
9 4.
Summary of Exposures at LWRs - 1977...........
10 5.
Exposures at BWRs and PWRs - 1977............
11 6.
Average Annual Dose Per Person at LWRs - 1977......
12 7.
Average Annual Dose Per Person at BWRs and PWRs - 1977 13 8.
Occupational Radiation Exposure Per Individual 15 9.
Sumary of Annual Whole Body Exposures By Increment.
16 10.
Overexposures at Commercial Power Reactors 18 11.
Personnel Dose by Work Function........
20 12.
Personnel Dose by Job Function at LWRs - 1977......
22 13.
Personnel Dose by Job Function at BWRs and PWRs.....
23 2305 038 vi
LIST OF FIGURES Figure Page 1.
Average Man-Rem Per Reactor-Year..
6 2.
Average Ma ~. N.r "'qawatt-Year 6
3.
Average Exposure Per Individual - 1969-1977 15 APPENDICES Appendix A - Personnel, Exposure and Power Generation Summary...................
25 Appendix B - Licensed Nuclear Power Facilities - 1977 Whole Body Exposures,10 CFR Part 20.407 Data 39 Appendix C - Annual Man-Rem Summary Regulatory Guide 1.16 Data 47 2305 039 vii
OCCUPATIONAL RADIATION EXPOSURE AT LIGHT WATER COOLED POWER REACTORS 1977 INTRODUCTION This report contains a compilation of the occupational radiation exposures at light water nuclear reactors (LWRs) for the years 1969 through 1977.
Data from those plants completing a full year of concercial operation for the first time in 1977 have been added to information previously collected and published as WASH-1311,I NUREG-75/032,2 NUREG-0109,3 and NUREG-0323.4 Appendix B of this report contains the data submitted to the USNRC in accordance with the requirements of 10 CFR Part 20.407, which annually requires power reactor licensees to submit a statistical summary report of personnel monitoring information recorded during the year. Appc7 dix C contains a compilation of information submitted annually to the NRC in accordance with individual license Technical Specifications require-ments and guidance provided in Regulatory Guide 1.16, " Reporting of Operating Information - Appendix A Technical Specifications."
2305 040 The compilation of occupational radiation exposure data through 1975 contained in reference (3) was reworked in some cases to remain consistent with aforementioned r quisites for inclusion in this document.
Figures on radiation exposure relating to work and job functions were calculated from data submitted by the licensees in accordance with guidance provided in Regulatory Guide 1.16 (see Appendix C). The plant operating data in Appendix A, including the calculated value of megawatt-years generated, was obtained or derived from information included in NUREG-0020-1, " Operating Units Status Report," January 1978. These reports are available in local public documen.t rooms (LPRDs) located near each licensed plant or in the U.S.
Nuclear Regulatory Commission's Public Document Room at 1717 H Street, Washington, D.C., 20555.
The tenn man-rem is a unit of collective dose and, as used in this report, is the summation of the occupational radiation exposures of all individuals at the plant site, including utility station personnel, other utility personnel brought in on a temporary basis, and contractor personnel.
Because all licensees did not report data consistently in the format suggested oy Regulatory Guide 1.16, the annual man-rem exposure figures used in all calculations (with the exception of Tables 11 and 12) were determined by summing the product of the numbers of individuals in each annual exposure range specified in 10 CFR 2305 041 Part 20.407 by the mid-point exposure in each range.
The annual man-rem totals thus determined are presented in Appendix A for each plant site.
Personnel figures used in all calculations were those reported in accordance with 10 CFR Part 20.407 because personnel data received from licensees varied with differing interpretations of s'gulatory Guide 1.16.
Personnel data for each plant site are included in Appendix A.
2305 042 TABLE 1 MAN-REM
SUMMARY
a.
SUMMARY
- LIGHT WATER REACTORS Average Yearly Number Rated Average Average Average of Capacity
- MW-Yr Man-Rem /
Man-Rem /
Reactors (MWe)
Generated Reactor-Year MW-Year 1969 7
247 167 178 1.1 1970 9
332 224 377 1.7 1971 11 318 257 315 1.2 1972 17 463 332 386 1.2 1973 23 526 336 594 1.8 1974 32 587 334 427 1.3 1975 44 644 406 457 1.1 1976 53 676 411 499 1.2 1977 57 688 436 570 1.2 b.
PRESSURIZED WATER REACTORS Average Yearly flumber Rated Average Average Average of Capacity
- MW-Yr Man-Rem /
Man-Rem /
Reactors (MWe)
Generated Reactor-Year MW-Year 1969 4
349 248 165 0.7 1970 4
349 245 685 2.8 1971 5
377 304 336 1.1 1972 8
464 287 464 1.4 1973 11 541 434 841 2.1 1974 18 613 367 364 1.0 1975 26 642 459 309 0.7 1976 30 699 444 460 1.0 1977 34 697 564 396 0.8 c.
BOILING WATER REACTORS Average Yearly Number Rated Average Average Average of Capacity
- MW-Yr Man-Rem /
Man-Rem /
Reactors (MWe)
Generated Reactor-Year MW-Year 1969 3
112 58 195 3.4 1970 5
318 207 131 0.6 1971 6
269 218 297 1.4 1972 9
463 340 318 0.9 1973 12 512 283 368 1.3 1974 14 553 290 507 1.7 1975 18 646 331 670 2.0 1976 23 647 367 549 1.5 1977 23 645 396 828 2.1
- Maximum Dependable Capacity (Net) - the dependable gross electrical output as measured at the output terminals of the turbine generator during the most restrictive seasonal conditions (usually summer) less the normal station service loads.
2305 043 PERSONNEL EXPOSURE
SUMMARY
Table i provides a summary of the plant data presented in Appendix A.*
Man-rem per reactor-year and man-rem per megawatt-year were cal-culated using annual man-rem figures reported by each light water cooled nuclear power reactor (LWR) that had operated commercially at least one full calendar year as of January 1, 1978. The average exposure per reactor-year and the average exposure per megawatt-year are presented in Table 1, summarized by all LWRs and categorized by pressurized water reactors (PWRs), and boiling water reactors (BWRs). The average exposure for each reactor at each station was determined by dividing the total exposure reported for the station by the number of reactors at that particular site.
The data presented in Table 1 has been plotted in Figures 1 and 2.
Figure 1 illustrates that the average man-rem per reactor-year for BWRs increased in 1977 while the average man-rem per reactor decreased for PWRs.
In Figure 2 the increase in man-rem per megawatt-year for BWRs is illustrated. Also, man-rem per megawatt-year is shown to have decreased for PWRs during the 1977 calendar year.
Analysis of the data from the period 1969 through 1977 determined that the 9-year average occupational exposure for operating BWRs was
- For multi-unit sites, the data displayed in Appendix A is the total for all units, with the exception of Millstone Units 1 and 2, which are presented separately as a BWR and PWR, respectively.
2305 044 FIGURE 1 AVER AGE MAN. REM /REACTOC YEAR l[. :(!!.
BWR 800 w:
pw 3_ _,,.
,j!/
(!!:
.:. /
\\:.::.
700 4'::
..:/
\\!!:
l.
i:/ i.
- ) \\.
../
g{::j:
6U *: :
- i7
\\ii..
. !!/
Yi..
- !/
ij!/
- s 500 +:: ji!1
$.i::
_ _ ::Y.
(@!:
E i:1
.7 ys
+.:.:!
i:
I
/
400 g
\\;.. :.:/
/
.!:1
- iy
/
- /
5 300 9!I
- 1
!/
200 P
100 I
I I
I I
I o
1969 1970 1971 1972 1973 1974 1975 1976 1977 YEAR FIGURE 2 AVERAGE MAN. REM /MW-YR 4.0 BWR 4::-
PWR- - - :
3.0
../ :i
- M. Q
.:.1 s%(:!!j.
.. ::/
\\....:-
. !:/
. ;ip'ti:
j 2.0
- /
2
\\!:
- ::/
\\.:-
~
-,/
(:::.
. W..
5<
\\:.
- .:p
\\
f
/
6' N
10 7 s s~%s',
,~
f o
i I
i 1969 1970 1971 1972 1973 1974 1975 1970 1977 YEAR 2305 045 approximately 1.7 man-rem per megawatt-year, and for PWRs was approximately 1.0 man-rem per megawatt-year.
Tne average man-ren per megawatt-year for all comercial light water cooled nuclear power reactors listed in Appendix A for this 9-year period was approximately 1.3 man-rem per megawatt-year.
Because this report is based on data from only 57 commercially operating nuclear power reactors, unusual events or conditions at even a small number of these reactors could have an inordinate impact on the results of any statistical analyses. Tables 2 through 7 present a listing of comercial operating plants ranked by man-rem per megawatt-year, man-rem per person and total man-rem exposure at each site.
These tables are included to illustrate the frequency distribution of selected plant site statistics.
The cost of generating electricity by nuclear nower, as measured in terms of man-rem exposure per megawatt-year generated, is displayed in Tables 2 and 3.
A large man-rem to megawatt-year ratio in combination with a high yearly man-rem total (Tables 4 and 5) generally indicates that a plant was shutdown for extensive maintenance or modifications.
In 1977 BWR's performed a great deal of feedwater nozzle sparger work which accounted for a large percentage of the exposures it these plants. Other major activities included work on core spray lines, the reactor water cleanup system, main steam isolation valves, and main condenser. At PWR's large exposures were incurred during inspection and repair of steam generator tubes.5 2305 046 TABLE 2
SUMMARY
OF MAN-REM PER MEGAWATT-YEAR AT LWRS - 1977
- Plant Site Man-Rem /MW-Yr Plant Site Man-Rem /MW-Yr
- 1. Palisades 0.16
- 20. Indian Point 1, 2, 3 0.88
- 2. Trojan 0.22
- 21. Robinson 2 0.89
- 3. St. Lucie 0.23
- 22. Calvert Cliffs 1 0.94
- 4. Beaver Valley 1 0.24
- 23. Hatch 1 1.04
- 5. Kewaunee 0.33
- 24. Quad Cities 1, 2 1.06 Prairie Island 1, 2 0.33 Turkey Point 3, 4 1.06
- 6. Cooper 0.37
- 25. Ginna 1.10
- 7. Maine Yankee 0.40
- 26. Haddam Neck 1.33
- 8. Arkansas 1 0.42
- 27. Dresden 1, 2, 3 1.49
- 9. Millstone 2 0.47
- 28. Peach Bottom 2, 3 1.93
- 10. Point Beach 1, 2 0.49
- 29. Surry 1, 2 2.03
- 11. Cook 1 0.52
- 30. Fitzpatrick 2.35
- 12. Three Mile Island 1 0.54 Monticello 2.35
- 13. Rancho Seco 0.55
- 31. Yankee Rowe 2.86
- 14. Vennont Yankee 0.61
- 32. San Onofre 1 3.00
- 15. Browns Ferry 1, 2 0.65
- 33. Brunswick 2 3.84
- 16. Millstone 1 0.68
- 34. Nine Mile Point 1 3.98
- 17. Zion 1, 2 0.74
- 35. Oyster Creek 4.18
- 18. Fort Calhoun 0.84
- 36. Big Rock Point 7.66
- 19. Duane Arnold 0.85
- 37. Pilgrim 1 9.92 Oconee 1, 2, 3 0.85
- 38. Lacrosse 19.82
- Note:
Humboldt Say did not operate in 1977 and is not included in this table.
2305 047
_9-TABLE 3 ftAN-REM PER MEGAWATT-YEAR AT BWRS AND PWRS 1977 A.
BWRS
- Plant Site Man-Rem /MW-Yr Plant Site flan-Rem /MW-Yr
- 1. Cooper 0.37
- 10. Fitzpatrick 2.35
- 2. Vermont Yankee 0.61 Monticello 2.35
- 3. Browns Ferry 1, 2 0.65
- 11. Brunswick 2 3.84
- 4. Millstone 1 0.68
- 12. Nine Mile Point 1 3.98
- 5. Duane Arnold 0.85
- 13. Oyster Creek 4.18
- 6. Hatch 1 1.04
- 14. Big Rock Point 7.66
- 7. Quad Cities 1, 2 1.06
- 15. Pilgrim 1 9.92
- 8. Dresden 1, 2, 3 1.49
- 16. Lacrosse 19.82
- 9. Peach Bottom 2, 3 1.93 B.
PWRS Plant Site Man-Rem /MW-Yr Plant Site Man-Rem /MW-Yr
- 1. Palisades 0.16
- 13. Zion 1, 2 0.74
- 2. Trojan 0.22
- 14. Fort Calhoun 0.84
- 3. St. Lucie 0.23
- 15. Oconee 1, 2, 3 0.85
- 4. Beaver Valley 1 0.24
- 16. Indian Point 1, 2, 3 0.88
- 5. Kewaunee 0.33
- 17. Robinson 2 0.89 Prairie Island 1, 2 0.33
- 18. Calvert Cliffs 1 0.94
- 6. Maine Yankee 0.40
- 19. Turkey Point 3, 4 1.06
- 7. Arkansas 1 0.42
- 20. Ginna 1.10
- 8. Millstone 2 0.47
?l. Haddam Neck 1.33
- 9. Point Beach 1, 2 0.49
- 22. Surry 1, 2 2.03
- 10. Cook 1 0.52
- 23. Yankee Rowe 2.86
- 11. Three Mile Island 1 0.54
- 24. San Onofre 3.01
- 12. Rancho Seco 0.55
- Note: Humboldt Bay did not operate in 1977 and is not included in this table.
2305 048 TABLE 4
SUMMARY
OF EXPOSURES AT LWRS - 1977 Total Total Plant Site Man-Rem Plant Site fian-Rem
- 1. Beaver Valley 1 87
- 22. Robinson 2 455
- 2. Palisades 100
- 23. Hatch 1 465
- 3. Kewaunee 139
- 24. Calvert Cliffs 1 547
- 4. St. Lucie 152
- 25. Haddam Neck 641
- 5. Trojan 174
- 26. San Onofre 1 847
- 6. Cooper 197
- 27. Browns Ferry 1, 2 863
- 7. Lacrosse 224
- 28. Monticello 1000
- 8. Millstone 2 242
- 29. Zion 1, 2 1003
- 9. Maine Yankee 245
- 30. Quad Cities 1, 2 1031
- 10. Arkansas 1 256
- 31. Turkey Point 3, 4 1036
- 11. Vermont Yankee 258
- 32. Indian Point 1, 2, 3 1070
- 12. Fort Calhoun 297
- 33. Fitzpatrick 1080
- 13. Cook 1 299
- 34. Brunswick 2 1119 Duane Arnold 299
- 35. Oconee 1, 2, 3 1328
- 14. Prairie Island 1, 2 300
- 36. Nine Mile Point 1383
- 15. Big Rock Point 334
- 37. Oyster Creek 1614
- 16. Yankee P. owe 356
- 38. Dresden 1, 2, 3 1693
- 17. Three Mile Island 1 359
- 39. Humboldt Bay 1904
- 18. Rancho Seco 390
- 40. Peach Bottom 2, 3 2036
- 19. Millstone 1 392
- 41. Surry 1, 2 2307
- 20. Ginna 4 01
- 42. Pilgrim 3142
- 21. Point Beach 1, 2 429 2305 049 f
TABLE 5 EXPOSURES AT BWRS AND PWRS - 1977 A.
BWRS Total Total Plant Site Man-Rem Plant Site Man-Rem
- 1. Cooper 197
- 10. Quad Cities 1, 2 1031
- 2. Lacrosse 224
- 11. Fitzpatrick 1080
- 3. Vermont Yankee 258
- 12. Brunswick 2 1119
- 4. Duane Arnold 299
- 13. Nine Mile Point 1383
- 5. Big Rock Point 334
- 14. Oyster Creek 1614
- 6. Millstone 1 392
- 15. Dresden 1, 2, 3 1693
- 7. Hatch 1 465
- 16. Humboldt Bay 1904
- 8. Browns Ferry 1, 2 863
- 17. Peach Bottom 2, 3 2036
- 9. Monticello 1000
- 18. Pilgrin 3142 B.
PWRS' ~
Total Total Plant Site Man-Rem Plant Site Man-Rem
- 1. Beaver Valley 1 87
- 14. Rancho Seco 390
- 2. Palisades 100
- 15. Ginna 401
- 3. Kewaunee 139
- 16. Point Beach 1, 2 429
- 4. St. Lucie 152
- 17. Robinson 2 455
- 5. Trojan 17;
- 18. Calvert Cliffs 1 547
- 6. Millstone 2 242
- 19. Haddam Neck 641
- 7. Maine Yankee 245
- 20. San Onofre 1 847
- 8. Arkansas 1 256
- 21. Zion 1, 2 1003
- 9. Fort Calhoun 297
- 22. Turkey Point 3, 4 1036
- 10. Cook 1 299
- 23. Indian Point 1, 2, 3 1070
- 11. Prairie Island 1, 2 300
- 24. Oconee 1, 2, 3 1328
- 12. Yankee Rowe 356
- 25. Surry 1, 2 2307
- 13. Three Mile Island 1 359 2305 050 TABLE 6 AVERAGE ANNUAL DOSE PER PERSON AT LWRS - 1977 Avg. Man-Rem Avg. Man-Rem Plant Site Per Person Plant Site Per Person
- 1. Calvert Cliffs 1 0.24
- 20. Brunswick 2 0.74
- 2. Beaver Valley 1 0.26
- 21. Ginna 0.76
- 3. Trojan 0.29 Rancho Seco 0.76
- 4. Palisades 0.30
- 22. Indian Point 1, 2, 3 0.77
- 5. Three Mile Island 1 0.32
- 23. Fitzpatrick 0.78
- 6. St. Lucie 0.34
- 24. Turkey Point 3, 4 0.79
- 7. Hatch 1 0.36
- 25. Oconee 1, 2, 3 0.83 Millstone 1 0.36
- 26. San Onofre 1 0.85 Millstone 2 0.36
- 27. Dresden 1, 2, 3 0.91
- 8. Cook 1 0.37
- 28. Oyster Creek 0.96
- 9. Vermont Yankee 0.40
- 29. Point Beach 1, 2 1.03
- 10. Prairie Island 1, 2 0.42
- 30. Quad Cities 1, 2 1.14
- 11. Arkansas 1 0.43
- 31. Monticello 1.16
- 12. Kewaunee 0.45
- 32. Surry 1, 2 1.24
- 13. Browns Ferry 1, 2 0.46
- 33. Nine Mile Point 1 1.27
- 14. Maine Yankee 0.48
- 34. Zion 1, 2 1.28
- 15. Yankee Rowe 0.49
- 35. Lacrosse 1.59
- 16. Duane Arnold 0.55
- 36. Pilgrim 1.68
- 17. Fort Calhoun 0.56
- 37. Humboldt Bay 1.79
- 18. Cooper 0.63
- 19. Big Rock Point 0.72 Haddam Neck 0.72 Peach Bottom 2, 3 0.72 Robinson 2 0.72 2305 051 TABLE 7 AVERAGE ANNUAL DOSE PER PERSON AT BWRS AND PWRS - 1977 A.
BWRs Avg. Man-Rem Avg. Man-Rem Plant Site Per Person Plant Site Per Person
- 1. Hatch 1 0.36
- 8. Fitzpatrick 0.78 Millstone 1 0.36
- 9. Dresden 1. 2, 3 0.91
- 2. Vermont Yankee 0.40
- 10. Oyster Creek 0.96
- 3. Browns Ferry 1, 2 0.46
- 11. Quad Cities 1, 2 1.14
- 4. Duane Arnold 0.55
- 12. Monticello 1.16
- 5. Cooper 0.63
- 13. Nine Mile Point 1 1.27
- 6. Big Rock Point 0.72
- 14. Lacrosse 1.59 Peach Bottom 2, 3 0.72
- 15. Pilgrim 1.68
- 7. Brunswick 2 0.74
- 16. Humboldt Bay 1.79 B.
PWRs Avg. Man-Rem Avg. Man-Rem Plant Site Per Person Plant Site Per Person
- 1. Calvert Cliffs 1 0.24
- 14. Fort Calhoun 0.56
- 2. Beaver Valley 1 0.26
- 15. Haddam Neck 0.72
- 3. Trojan 0.29 Robinson 2 0.72
- 4. Palisades 0.30
- 16. Ginna 0.76
- 5. Three Mile Island 1 0.32 Rancho Seco 0.76
- 6. St. Lucie 0.34
- 17. Indian Point 1, 2, 3 0.77
- 7. Millstone 2 0.36
- 18. Turkey Point 3, 4 0.79
- 8. Cook 1 0.37
- 19. Oconee 1, 2, 3 0.83
- 9. Prairie Island 1, 2 0.42
- 20. San Onofre 1 0.85
- 10. Arkansas 1 0.43
- 21. Point Beach 1, 2 1.03
- 11. Kewaunee 0.45
- 22. Surry 1, 2 1.24
- 12. Maine Yankee 0.48
- 23. Zicn 1, 2 1.28
- 13. Yankee Rowe 0.49 2305 052 Additional information on repair and maintenance activities at each plant can be found in the report, Nuclear Power Plant Operating Experience, NUREG-0483.6 EXPOSURE TO INDIVIDUALS As shown in Table 8, an average of 742 persons per reactor received measurable exposure at commercial LWRs in 1977.
This represents an increase of 11% over the number of personnel per reactor that received measurable exposure in 1976.
The average exposure per individual increased slightly to approximately 0.8 rem in 1977.
Figure 3 presents a summary of information collected from commercial nuclear operating reactors for the period 1969 through 1977.
During this nine year period, the number of reactors in commercial operation has increased from 7 LWRs in 1969 to 57 in 1977.
The total number of individuals who received measurable exposure at all LWRs, and the average exposure per person, are presented with the number of individuals monitored for exposiire and the total annual dose received each year.
As Figure 3 illustrates, the total man-rem received each year has been distributed over an increasingly large work force.
Table 9 is a sumary of the annual whole body exposures received by the individuals monitored for exposure at LWRs.
The individual 2305 053 TABLE 8 OCCUPATIONAL RADIATION EXPOSURE PER INDIVIDUAL Average Number of Average Exposure Personnel With Per Individual Measurable Exposure Year (Rems)
Per Reactor 1969 1.7 149 1970 1.3 380 1971 1.2 309 1972 0.7 345 1973 0.9 634 1974 0.8 567 1975 0 7*
625 1976 0.7 669 1977 0.8 742
- This figure was recalculated to reflect a correction in the 1975 Appendix A personnel data for Surry 1&2.
FIGURE 3 AVERAGE EXPOSURE PER INDIVIDUAL 1969 -1977 Total le. Jividuals Monitored 70 Total With Measurable Exposure Man-R e.a/Y ear (All LWRs) ---=
60 Average Exposure
=
E Per Individual (Rem) g
- - = =
==
f 50 2.0 m d^
E (E
\\
5 0j 40 =\\
jj
\\
..**,.+
1.5 g
}
\\
/j/v j
30
[
=
N ci g
/
1.0 y
\\
/ ' -
E-20
/
,,...*_,, g
/
0.5
,so+-
/p/
to s**
- pa a.=W,
r#
1 I
I I
I i
1969 1970 1971 1972 1973 1974 1975 1976 1977
- Note: Data on personnel monitored who received no measurable exposure not available prior to 1973.
2305 054
TABLE 9 SUT@tARY OF ANNUAL WHOLE BODY EXPOSURES BY INCREMENT - LWR'S 5 (For Those Personnel at Licensee Stations Included in Appendix A)
Number of Individuals No Exposure Increrent - Rems Total With Measurable Measurable Total Year Exposure 0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11 Exposure Monitored 0-2 1969 2607 144 70 26 5
2 0
0 0
0 0
2854 2854 1970 6953 184 175 92 102 11 1
0 0
0 0
7518 7518 1971 9660 328 146 107 17 11 0
0 0
0 0
10269 10269 1972 14783 536 205 114 47 23 10 6
6 0
0 15730 15730 5
1973 20717 10249 2449 1585 432 237 117 71 38 16 7
0 0
15201 35918 1974 20240 13455 2491 1375 470 226 86 30 6
0 0
0 0
18139 38379 1975 20188 18277 3892 1903 707 426 169 60 24 12 0
1 0
25471 45659 1976 25704 26636 4880 2354 789 487 188 70 26 11 5
1 0
35447 61151 1977 24868 31298 6162 2837 1130 569 141 66 36 21 6
0 0
42266 67134 N
tra O
LJ1 O
LJ1 t_D exposures occurring during the period 1969-1977 have been categorized by the exposure increments specified in 10 CFR Part 20.407(b).
In 1977 the total number of individuals monitored for exposure at licensed LWRs increased 10% over the 1976 figure.
During this same period, the number of personnel receiving measurable exposure increased approximately 19%. The data indicate that the number of individuals that received whole body exposures less than 5 rem increased 19% in 1977, but that acnual doses in excess of 5 rem decreased by 10%.
The number of persons receiving whole body exposures in excess of the limits established by 10 CFR Part 20.101 at commercial reactors are reported for the years 1971 through 1977 in Table 10.
During 1977 the requirement in 10 CFR Part 20.405 for reporting exposures to excessive concentrations of radioactive material was changed from 40 MPC-hours (Maximum Permissable Concentration per hour) in any seven consecutive days to 520 MPC-hours in any calendar quarter. Approximatcly 0.04%
of the persons monitored for radiation exposure at comcrcial reactors received whole body overexposures in 1977.
EXPOSURE BY WORK AND JOB FUNCTION Tables 11,12 and 13 present data submitted in accordance with Regulatory Guide 1.16 on radiction exposures at commercial nuclear power reactors.
Licensees are requested to categorize exposure and personnel data by work and job functions specified in Reg. Guide 1.16.
In some 2305 056
TABLE 10 5
OVEREXPOSURES AT COMMERICAL POWER REACTORS Number of Whole Body Whole Body Report of Exposure to Overexposures to Man-Rem Maximum Excessive Concentration Maximum Year External Radiation Involved Exposure (Rems) of Radioactive Material Exposure 1971 2
4.5 3.1 21 6.1 rem (thyroid) 1972 16 49.7 5.1 2
2000 MPC-hr 1973 19 61.2 4.0 0
1974 43 155.9
'6.1 12 433 MPC-hr 1975 14 44.2 3.8 7
13.5 rem (lung) 1976 20 74.3 10.1 1
248 MPC-hr 1977 28 56.0 3.6 0
g u
O Ln C
Cn N
cases, licensee data required recategorization by NRC staff.
These cases are so noted in Appendix C.
Categorization of personnel data is not included in this report because personnel data received from the licensees continue to vary due to differing interpretations of the format guidance presented in Regulatory Guide 1.16.*
Table lla displays the distribution of exposure by work function as reported by the licensees. Workers involved in routine and special maintenance functions continue to acquire approximately 71% of all exposures at nuclear power plants, as was the case in 1975 and 1976.
The total dose to contractor personnel exceeded exposures to utility personnel (utility personnel brought in on a temporary basis as well as those individuals who are uti'lity station personnel) by approximately 6% in 1977.
Contractor personnel, however, received a greater percentage of exposure than utility personnel in only two work functions, Inservice Inspection and Special Maintenance.
Exposures to contractor personnel performing special maintenance functions were almost two and one-half times the total dose received by utility personnel in the same category.
Categorization of personnel dose in 1977 by job function is presented in Table 12.
Each work function listed in Table 11 is subdivided into five basic job functions: Maintenance, Operations,
- Regulatory Guide 1.16 is currently under revision. Proposed changes will provide further clarification on reporting of personnel data and.should eliminate this problem.
2305 058 TABLE 11 PERSONNEL DOSE BY WORK FUNCTION (1977)
PER DATA SUPPLIED BY LICENSEE IN ACCORDANCE WITH R.G.1.16 a.
TABULATION OF MAN-REM BY WORK FUNCTION Contract Work Station Utility Workers Function Employees Employees and Others Total Reactor Operations 2626 224 427 3277 Routine Maintenance 3470 1544 3708 8722 Inservice Inspection 205 245 1536 1986 Special Maintenance 1700 2123 9398 13221 Waste Processing 1207 36 554 1797 Refueling 852 390 829 207_1 Totals 10060 4562 16452 31074 b.
PERCENTAGES OF EXPOSURE BY WORK FUNCTION Work Function Utility Contractor Total Reactor Operations 9.2%
1.4%
10.5%
Routine Maintenance 16.1%
11.9%
28.1%
Inservice Inspection 1.5%
4.9%
6.4%
Special Maintenance 12.3%
30.2%
42.5%
Waste Processing 4.0%
1.8%
5.8%
Refueling 4.0%
2.7%
6.7%
Totals 47.1%
52.9%
100%
2305 059 Health Physics, Supervisory and Engineering. Over 70% of reported exposures occurred in the maintenance functions.
Utility personnel exposures exceeded contractor exposures except in maintenance and engineering.
By job function, total dose to contractor personnel exceeded utility exposures by approximately 4% in 1977. Table 13 displays a breakdown of this data by BWRs and PWRs.
2305 060 TABLE 12 PERSONNEL DOSE BY JOB FUNCTION AT LWR'S (1977) a.
TABULATION OF ANNUAL DCSE BY JOB FUNCTION (REMS)
Personnel Contract Job Station Utility Workers Function Employees Employees and Others Total Maintenance 4182 3759 11569 19510
^
Operations 2485 69 47 2601 Health Physics 943 36 865 1844 Supervisory 648 79 401 1128 Engineering 556 288 1170 2014 TOTALS 8814 4231 14052 27097*
b.
PERCENTAGES OF EXPOSURE BY JOB FUNCTION Personnel Job Function Utility Contractor Total Maintenance 29.3%
42.7%
72.0%
Operations 9.4%
0.2%
9.6%
Health Physics 3.6%
3.2%
6.8%
Supervisory 2.7%
1.5%
4.2%
Engineering 3.1%
4.3%
7.4%
TOTALS 48.1%
51.9%
100%
- The remaining 3977 man-rem of the 31074 man-rem total reported in Table 5 were not categorized by job function by the licensees.
2305 06l TABLE 13 PERSONNEL DOSE BY JOB FUNCTION AT BWRs AND PWRs (1977) a.
ANNUAL DOSE BY JOB FUNCTION AT BWRs (REMS)
Personnel Contract Job Station Workers Function Employees and Others Total Maintenance 4354 8060 12414 Operations 1614 46 1660 Health Physics 541 569 1110 Supervisory 513 196 709 Engineering 462 784 1246 TOTALS 7484 9655 17139 b.
ANNUAL DOSE BY JOB FUNCTION AT PWRs (REMS)
Personnel Contract Job Station Workers Function Employees and Others Total Maintenance 3587 3509 7096 Operations 940 1
941 Health Physics 438 296 734 Supervisory 214 205 419 Engineering 382 386 768 TOTALS 5561 4397 9958 2305 062 REFERENCES 1.
Murphy, T.
D., A Compilation of Occupational Radiation Exposures from Light Water Cooled Nuclear Power Plants, 1969-1973, USAEC, WASH-1311, May 1974.
2.
Murphy, T.
D., Hinson, C.
S., Occupational Radiation Exposures at Light Water Cooled Nuclear Power Reactors, 1969-1974, USNRC, NUREG-75/032, June 1975.
3.
Murphy, T.
D., et al., Occupational Radiation Exposure at Light Water Cooled Nuclear Power Reactors, 1969-1975, NUREG-0109.
4.
Johnson, L. A., Occupational Radiation Exposure at Light Water Cooled Power Reactors,1976, USNRC, NUREG-0323, March 1978.
5.
Brooks, B. G., Occupational Radiation Exposure, Tenth Annual Report,1977, USNRC, NUREG-0463, October 1978.
6.
Beebe, M.
R., Nuclear Power Plant Operating Experience, NUREG-0483, February 1979.
2305 063
APPENDIX A PERSONNEL, EXPOSURE AND POWER GENERATION
SUMMARY
NOTE:
Personnel and man-rem data in this Appendix were derived from licensee reports submitted in accordance with 10 CFR 20.407.
2305 064
Mega-Unit PERSONNEL ANNUAL MAN-REM Average watt Availa-Exposure MAN-REM Total year bility With Opera-Main-Contrac-Station /
REM per per Reporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR ARKANSAS 1 1975 588.0 76.5 147 46 0.31 0.1 Docket 50-313; DPR-51 1976 464.6 56.6 476 289 27 262 100 189 0.61 0.62 1st comercial operation 12/74 1977 610.3 76.8 601 256 28 228 111 145 0.43 0.42 Type - PWR Capacity - 836 MWe BEAVER VALLEY 1 1977 355.6 57.0 331 87 8
79 58 29 0.26 0.24 Docket 50-334; DPR-66 lst comercial operation 10/76 Type - PWR Capacity - 800 MWe C3 BIG ROCK POINT 1969 43.2 165 136 0.82 3.1 i
Docket 50-155; DPR-6 1970 43.5 090 194 0.67 4.5 1st comercial operation 3/63 1971 44.4 co0 184 0.7 4.1 Type - BWR 1972 43.5 195 181 0.92 4.1 Capacity - 65 MWe 1973 50.9 119 336 140 196 2.8 6.6 1974 40.7 70.3 281 276 54 222 42 234 0.98 6.6 1975 35.1 59.8 216 180 58 122 20 160 0.83 5.1 1976 29.5 50.1 488 289 82 207 105 184 0.59 9.80 1977 43.6 73.4 465 334 94 240 60 274 0.72 7.66 g
U C
BROWNS FERRY 1, 2 1975 328.9 17.8 2380 325 0.14 1.0 W Docket 50-259, 50-260; DPR-33, -52 1976 337.6 26.9 2207 234 0.11 0.69 1st comercial operation 8/74 O
3/75 1977 1327.5 73.0 1858 863 60 803 249 614 0.46 0.65 Type - BWR u
Capacity - 1065 MWe, 1065 MWe
Mega-Unit PERSONNEL ANNUAL MAN-REM Average Exposure MAN-REM Watt Availa-Total year bility With Opera-Main-Contrac-Station /
REM per per Reporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR BRUNSWICK 2 1976 297.2 56.0 1265 326 15 311 222 104 0.26 1.10 Docket 50-234; DPR-62 1977 291.1 55.7 1512 1119 48 1071 782 337 0.74 3.84 1st comercial operation 11/75 Type - BWR Capacity - 790 MWe CALVERT CLIFFS 1 1976 753.4 95.2 507 74 28 46 8
66 0.15 0.10 Docket 50-317; DPR-53 1977 583.0 72.1 2265 547 36 511 224 323 0.24 0.94 1st comercial operation 5/75 Type - PWR Capacity - 810 MWe E!
COOK 1 1976 807.4 83.1 395 116 13 103 71 45 0.29 0.14 Docket 50-315; DPR-58 1977 573.0 76.1 802 299 21 278 138 161 0.37 0.52 1st comercial operation 8/75 Type - PWR Capacity - 1044 MWe COOPER STATION 1975 456.4 83.6 175 96 25 71 16 80 0.55 0.2 Docket 50-298; DPR-46 1976 433.3 75.5 763 350 39 311 210 140 0.46 0.81 1st comercial operation 7/74 1977 538.2 86.2 315 197 50 147 66 131 0.63 0.37 Type - BWR Capacity - 764 MWe NW Q
L rt Qm m
Mega-Unit PERSONNEL ANNUAL MAN-REM Average watt Availa-Exposure MAN-REM Total year bility With Opera-Main-Contrac-Station /
REM per per Reporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR DRESDEN 1, 2, 3 1969 89.4 286 3.2 Docket 50-10, 50-237, 50-249; 1970 304.0 143
.5 DPR-10, -19, -25 1971 394.5 715 1.8 1st comercial operation 7/60, 1972 1243.7 728
.6 6/72, 11/71 1973 1112.2 1341 909 138 771 333 576 0.68
.8 Type - BWR 1974 842.5 54.9 1594 1662 57 1605 1.04 2.0 Capacity - 197, 772, 773 MWe 1975 708.1 54.6 3671 3209 254 2955 2111 1098 0.87 4.5 1976 1127.2 80.8 1746 1680 228 1452 749 931 0.96 1.49 1977 1132.9 77.0 1862 1693 316 1377 693 1000 0.91 1.49 DUANE ARNOLD 1976 305.2 78.0 350 105 14 91 62 43 0.30 0.34 Docket 50-331; DPR-49 1977 353.6 78.9 538 299 36 263 221 79 0.55 0.85 1st comercial operation 2/75
[
Type - BWR e
Capacity - 515 MWe e
FITZPATRICK 1976 489.0 71.6 600 202 0.34 0.41 Docket 50-333; DPR-59 1977 460.5 68.4 1380 1080 14 1066 937 143 0.78 2.35 1st comercial operation 7/75 Type - BWR Capacity - 800 MWe FORT CALHOUN 1975 252.3 67.4 469 298 93 205 0.63 1.2 N Docket 50-285; DPR-40 1976 265.9 69.5 516 31 3 28 285 38 275 0.61 1.18 U lst comercial operation 6/74 1977 351.8 79.4 535 297 33 264 72 225 0.56 0.84 O Type - PWR
( n Capacity - 445 MWe O
N
~.
Mega-Unit PERSONNEL ANNUAL MAN-REM Average watt Availa-Exposure MAN-REM Total year bility With Opera-Main-Contrac-Station /
REM per per Peporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR GINNA 1970 268.5 170 20 94 113 15 192 1.21 0.8 Docket 50-244; DPR-18 1971 327.8 340 43u 69 361 108 322 1.26 1.3 1st comercial operation 3/70 1972 295.6 677 1032 71 961 278 754 1.52 3.4 Type - PWR 1973 409.5 421 244 60 184 91 153 0.58 0.6 Capacity - 470 FWe 1974 253.7 62.4 884 1224 1.38 4.8 1975 365.2 76.7 558 496 0.89 1.4 1976 248.8 58.2 758 636 29 607 210 426 0.84 2.56 1977 365.6 85.5 530 401 15 386 120 281 0.76 1.10 HADDAM NECK (CONN. YANKEE) 1969 397.6 138 106 27 79 0.77 0.5 b
Docket 50-213; DPR-61 1970 424.7 734 689 463 226 0.94 1.7 o
1st comercial operation 1/68 1971 502.2 289 342 166 176 1.18 0.8 Type - PWR 1972 515.6 355 325 181 144 0.91 0.7 Capacity - 550 MWe 1973 293.1 841 673 525 148 0.80 2.1 1974 519.1 91.2 550 201 0.37 0.4 1975 494.3 89.9 795 669 19 650 0.84 1.4 1976 482.9 82.5 644 449 5
444 253 196 0.70 0.93 1977 480.7 83.9 894 641 59 582 440 201 0.72 1.33 HATCH l' 1976 496.3 83.8 630 134 79 55 4
130 0.21 0.27 Docket 50-321; DPR-57
'S//
446.8 66.3 1303 465 96 369 220 245 0.36 1.04 1st comercial operation 12/75 Type - BWil M apacity - 700 MWe UJ Q
Cn O
CD
Mega-Unit PERSONNEL ANNUAL MAN-REM Average watt Availa-Exposure MAN-REM Total year bility With Opera-Main-Contrac-Station /
REM per per Reporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR HUMBOLDT BAY 1969 40.6 125 164 69 95 12 152 1.31 4.0 Docket 50-133; DPR-7 1970 49.3 115 209 130 79 37 172 1.81 4.3 1st comercial operation 2/63 1971 39.6 140 292 114 178 65 227 2.1 7.7 Type - BWR 1972 43.1 127 253 81 172 57 116 1.99 5.9 Capacity - 63 MWe 1973 50.1 235 261 59 202 1.11 5.3 1974 43.4 83.8 296 318 103 215 1.07 7.1 1975 45.3 83.9 303 332 128 204 110 222 1.10 7.3 1976 23.5 46.4 523 683 37 646 50 633 1.31 29.1 1977 0
0 1063 1904 24 1880 973 931 1.79 S
- INDIAN POINT 1, 2, 3 1969 183.3 298 1.6 Docket 50-3, 50-247, 50-286; 1970 43.3 1639 33.0 DPR-5, -26, -64 1971 154.0 76E 5.0 ist comercial operation 10/62, 1972 142.3 967 6.6 8/73, 8/76 1973 0
2998 5134 692 4442 2778 2356 1.71 Type - PWR 1974 556.1 59.4 1019 910 0.89 1.6 Capacity - 0, 864, 873 MWe 1975 584.4 74.8 480 626 147 479 42 584 1.3 1.1 1976 273.9 34.8 1590 1950 154 1796 172 1778 1.23 7.12 1977 1278.3 75.3 1391 1070 189 881 383 687 0.77 0.88 KEWAUNEE 1975 401.9 88.2 54 25 1
24 11 14 0.5 0.06 IM Docket 50-305; DPR-43 1976 405.9 78.9 381 270 16 254 193 77 0.71 0.67 u
ist comercial operation 6/74 1977 425.0 79.9 312 139 8
131 76 63 0.45 0.33 o
Type - PWR m
Capacity - 521 MWe Og
- INDIAN P0 INT 1 was defueled in 1975.
g
Mega-Unit PERSONNEL ANNUAL MAN-REM Average Exposure MAN-REM watt Availa-Total year bility With Opera-Main-Contrac-Station /
REM per per Reporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR LACROSSE 1971 33.1 218 158 0.72 5.0 Docket 50-409; DPR-45 1972 29.2 151 172 1.13 5.9 1st comercial operation 9/69 1973 24.4 157 221 1.41 9.1 Type - BWR 1974 37.9 81.0 115 139 89 50 6
133 1.21 3.7 Capacity - 48 MWe 1975 32.0 69.6 165 234 1.42 7.3 1976 21.2 47.6 118 111 40 71 6
105 0.94 5.24 1977 11.3 33.7 141 224 60 164 8
216 1.59 19.82 MAINE YANKEE 1973 408.7 422 121 61 60 0.29 0.3 Docket 50-209; DPR-36 1974 432.6 63.7 620 420 64 356 188 232 0.68 1.0 1st comercial operation 12/72 1975 542.9 79.9 577 347 16 331 197 150 0.60 0.6 Type - PWR 1976 712.2 95.0 244 85 27 58 26 59 0.35 0.12 M
Capacity - 760 MWe 1977 617.6 82.2 508 245 46 199 112 133 0.48 0.40 i
MILLSTONE POINT 1 1972 377.6 612 596 50 546 340 256 0.97 1.6 Docket 50-245; DPR-21 1973 225.1 1152 620 117 503 395 225 0.54 2.7 1st corrnercial operation 3/71 1974 430.3 79.1 2477 1430 0.58 3.3 Typf - BWR 1975 465.4 75.6 2587 2022 0.78 4.3 Capacity - 654 MWe 1976 449.8 76.1 1377 1194 54 1140 955 239 0.87 2.65 1977 575.7 89.6 1075 392 118 274 159 233 0.36 0.68 MILT. STONE POINT 2 1976 545.7 78.7 620 168 26 142 73 95 0.27 0.31 g
Docket 50-336; DPR-65 1977 518.7 65.7 667 242 38 204 153 89 0.36 0.47 lst comercial operation 12/75 O
Type - PWR W
Capacity - 796 MWe O
N O
w" '
e M
E R
55 88 65 R rY 140953 26831989 7368
- e -
N pW 001302 00012103 0000 A
M M
e errn gueo 161 16 59841497 1443 asps 654081 01391002 6888 ro r
e pM e 000101 00001111 0000 vxE p AER
/ny ot 058 29 79895890 3475 ii tl 695 13 28904790 7703 2
23 145415 3380 ai 1
tt SU
-ca 191 11 73889393 4395 rr 59 56 16207028 4819 t o 6
12228 1
22 nt o
M C
E R
e N
c A
- n 12 45 22602362 9114 M
na 21 06 35298174 9968 i n 1
28 1237633 4390 L
ae 1
1 A
Mt U
N N
A as rn 02 95 23972821 8654 eo 44 53 14524654 1664 pi 1
1 2
Ot la 149330 45574183 7768 t
654560 49812828 1522 o
13320 1258643 5403 T
1 1
1 11 L
e E
r N
l hu 962350 16500923 4155 N
a ts 974526 20354499 4419 O
t io S
o 28338 80757630 8525 Wp 1
1 1
11 R
T x
E E
P l
l
-ayr tl t o 9259 5122 1509 iiit nal c 4219 0289 0535 Uvia
/797 7785 6766 AbF
)
R 453846 05809064 at rY u
3341 gt a -
499465 76115947 4819 eaeW 284472 24818584 2366 433344 23343343 7855 M w yM(
111 r
234567 01234567 4567 a
777777 77777777 7777 e
999999 99999999 9999 Y
111111 11111111 1111 9
1 6
3 7
/
7 e
/
2
/
W 6
1 7
M n
7 o
n n
8 n
0 i
o o
2 o
6 t
i i
- i 8
a 2t 3t t
z 2a 6a
, a i
r
- r 0
r 0
n Re e
Re e
75e 6
1 a
P p W
Pp W
25p 8
g Do M Do M
- - o r
T O
- l 6
N ;l 0
3,
,l 0
3a 3
I 0a 1
97a4 6
g 6i 5
O2i 6
,64i7 8
n 3c P2c 22 - c/
i O - rR -
rR -
r2R -
t L0eW E0eW
,0
.e1 W 158n L5 mB y L5mBy
,P y r
i I
t 3c t
o E
t p
Ctoi Mtoi Et - o4 i
e I ec c
ec c
E eRc7 c
R Tk ea Ek ea NkP
/ea Nctpp Nctpp O cD t9 pp Oosya I osya C o s
ya MDlTC NDlTC OD l
TC guOW ON....
Mega-Unit PERSONNEL ANNUAL MAN-REM Average watt Ava11a-Total Exposure MAN-REM year bility With 2ra-Main-Contrac-Station /
REM per per Reportino Organization Year (MW-YR)
Factor Exposure Total ons tenance tor Utility person MW-YR
~'
OYSTER CREEK 1969 40.1 Docket 50-219; DFF.-16 1970 413.6 95 63 21 42 11 52 0.66 0.2 1st comercial operation 12/69 1971 448.9 249 240 50 190 92 148 0.96 0.5 Type - BWR 1972 51 5.0 339 582 150 432 167 415 1,71 1.1 Capacity - 620 MWe 1973 424.6 782 1236 195 1041 683 553 1.58 2.9 1974 434.5 70.4 935 984 166 818 162 822 1.05 2.3 1975 373.6 73.3 1210 1132 168 964 269 863 0.94 3.0 1976 456.5 79.3 1582 1078 70 1008 587 491 0.68 2.36 1977 385.7 70.1 1673 1614 76 1538 1048 566 0.96 4.18 PALISADES 1972 21 6.8 78 Docket 50-255; DPR-20 1973 286.8 9 01 1109 16 1093 647 462 1.23 3.8 1st conraercial operation 12/7]
1974 10.5 5.5 774 627 0.81 60.0 Type - PWR 1975 300.2 64.5 474 292 0.62 0.97 Capacity - 635 MWe 1976 346.9 55.2 742 696 23 673 109 587 0.94 2.01 1977 616.6 91.4 332 100 13 87 23 77 0.30 0.16 PEACH BOTTOM 2, 3 1975 1234.3 80.9 9/1 228 0.24 0.18 Docket 50-277; -278; DPR-44, -56 1976 1379.2 73.0 2136 840 180 660 434 406 0.39 0.61 1st comercial operation 12/74, 1977 1052.4 58.7 2827 2036 223 1813 1374 662 0.72 1.93 12/74 Type - 8WR Capacity - 1051,1035 MWe PILGRIM 1 1973 484.0 53 74 29 45 1.4 0.2 Docket 50-293; DPR-35 1974 234.1 39.2 454 415 0.91 1.8 N
lst comercial operation 12/72 1975 308.1 71.3 473 744 132 612 34 360 1.6 2.4 U
Type - BWR 1976 287.8 60.7 1317 2648 66 2582 2270 378 2.01 9.2 O
Capacity - 670 MWe 1977 316.6 61.4 1875 3142 146 2996 2176 966 1.68 9.92 C 71 O
N N
Mega-Unit PERSONNEL ANNUAL MAN-REM Average watt Availa-Exposure MAN-REM Total year bility With Opera-Main-Contrac-Station /
REM per per Reporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR P0 INT BEACH 1, 2 1972 378.3 580 1.5 Docket 50-266; -301; DPR-24, -27 1973 693.7 729 570 70 500 0.78 0.8 1st comercial operation 12/70 1974 760.2 81.3 400 295 70 225 81 214 0.74 0.4 4/73 1975 801.2 82.9 339 456 1.3 0.6 Type - PWR 1976 857.3 86.7 313 370 58 312 107 263 1.18 0.43 Capacity - 495, 495 MWe 1977 873.9 87.3 417 429 63 366 212 217 1.03 0.49 PRAIRIE ISLAND 1, 2 1974 181.9 43.9 150 18 5
13 0.12 0.1 Docket 50-282, -306; DPR-42, -60 1975 836.0 83.3 477 123 0.26 0.15 1st comercial operation 12/73, 1976 725.2 76.6 818 447 68 379 235 212 0.55 0.62 12/74 1977 922.9 87.2 718 300 73 227 60 240 0.42 0.33 8
Type, PWR Capacity - 507, 507 MWe M
i QUAD CITIES 1, 2 1973 1209.6 533 201 28 173 59 142 0.37 0.2 Docket 50-254. -265; DPR-29. -30 1974 958.1 72.3 678 482 36 446 0.71 0.5 1st comercial operation 2/73, 1975 833.6 68.4 1972 1385 98 1287 592 793 0.70 1.7 3/73 1976 951.2 73.1 1225 1651 269 1382 648 1003 1.35 1.74 Type - BWR 1977 970.1 84.0 907 1031 108 923 373 658 1.14 1.06 Capacity - 769, 769 MWe RANCHO SECO 1976 268.1 30.4 297 58 6
52 17 41 '
O.20 0.22 N Docket 50-312; DPR-54 1977 706.4 77.1 51 5 390 61 329 248 142 0.76 0.55 u ist comercial operation 4/75 o Type - PWR m Capacity - 873 MWe O
N U
Mega-Unit PERSONNEL ANNUAL MAN-REM Average watt Availa-Total Exposure PAN-REM year bility With Opera-Main-Contrac-Station /
REM per per Reporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR ROBINSON 2 1971 295.3 283 364 7
357 351 13 1.28 1.2 Docket 50-261; DPR-23 1972 580.0 245 215 42 173 137 78 0.87 0.4 ist comercial operation 3/71 1973 455.1 831 695 0.83 1.5 Type - PWR 1974 578.1 83.3 853 672 185 487 0.78 1.2 Capacity - 665 MWe 1975 501.8 72.7 849 1142 1.35 2.3 1976 585.5 84.7 597 715 30 685 457 758 1.20 1.22 1977 511.5 85.2 634 455 52 403 191 199 0.72 0.89 SAN ON0FRE 1 1969 289.8 123 42 10 32 5
37 0.34 0.2 Docket 50-206; DPR-13 1970 365.9 251 155 13 142 59 96 0.bl 0.4 1st conTnercial operation 1/68 1971 362.1 121 50 12 38 3
47 0.41 0.1 Type - PWR 1972 372.2 326 256 29 227 117 139 0.78 0.7 Capacity - 436 MWe 1973 273.7 878 329 37 292 157 172 0.37 1.2 e
1974 377.8 86.1 219 71 0.32 0.2 ta 1975 389.0 87.4 424 292 0.75 0.7 1976 297.9 70.2 1330 880 147 733 629 251 0.66 2.95 1977 281.2 63.7 985 847 77 770 451 396 0.85 3.0 ST. LUCIE 1 1977 788.4 92.6 591 174 30 144 105 69 0.29 0.22 Docket 50-335; DPR-67 1st coninercial operation 12/76
}
Type - PWR Capacity - 777 MWe SURRY 1. 2 1973 829.4 936 152 0.16 0.2 Docket 50-280, -281; DPR-32. -37 1974 717.4 49.8 1715 884 72 812 0.52 1.2 O
lst comercial operation 12/72, 1975 1029.7 70.8 1948 1549 25 1524 1000 549 0.8 1.5 W
5/73 1976 930.7 60.4 2753 3165 444 2721 1873 1292 1.15 3.40 Type - PWR 1977 1139.0 72.2 1860 2307 348 1959 1380 927 1.24 2.03 O
Capacity - 775, 775 MWe N
A
Mega-Unit PERSONNEL ANNUAL MAN-REM Average watt Availa-Exposure MAN-REM Total year bility With Opera-Main-Contrac-Station /
REM per per Reporting Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR THREE MILE ISLAND 1 1975 675.9 82.2 168 83 21 62 0.49 0.1 Docket 50-289; DPR-50 1976 530.0 65.4 819' 286 23 263 69 217 0.35 0.54 1st comercial operation 9/74 1977 664.5 80.9 1122 359 15 344 128 231 0.32 0.54 Type - PWR Capacity - 792 MWe TROJAff 1977 788.4 92.6 591 174 30 144 105 69 0.29 0.22 Docket 50-344; NPF-1 ist comercial operation 5/76 Type - PWR Capacity - 1080 MWe D
TURKEY POINT 3, 4 1973 565.9 444 78 0.18 0.1 i
Docket 50-250, -251; DPR-31, -41 1974 966.4 794 454 88 366 202 252 0.57 0.5 lst comercial operation 12/72, 1975 1003.7 74.9 1175 875 270 605 558 317 0.74 0.87 9/73 1976 974.2 71.2 1647 1184 89 1095 868 316 0.72 1.21 Type - PWR 1977 979.5 82.8 1319 1036 94 942 522 514 0.79 1.06 Capacity - 666, 666 MWe VERMONT YANKEE 1973 222.1 244 85 0.35 0.4 N
Docket 50-271; DPR-28 1974 303.5 357 216 24 192 103 113 0.61 0.7 1st comercial operation 11/72 1975 429.0 87.8 247 139 64 75 57 82 0.56 0.3 O Type - BWR 1976 389.6 77.1 81 5 411 36 375 246 165 0.50 1.05 W Capacity - 504 MWe 1977 423.5 85.1 641 258 83 175 90 168 0.40 0.61 l
O N
Mega-Unit PERSONNEL TNNUAL MAN-REM Average watt Availa-Exposure MAN-REM Total year bility With Opera-Main-Contrat. Station /
REM per per Reportinq Organization Year (MW-YR)
Factor Exposure Total tions tenance tor Utility person MW-YR YANKEE R0WE 1969 123.1 193 215 46 169 78 91 1.1 1.8 Docket 50-29; DPR-3 1970 146.1 355 255 60 195 98 97 0.71 1.8 1st comercial operation 7/61 1971 173.5 155 90 44 46 19 71 0.58 0.5 Type - PWR 1972 78.7 282 255 60 195 147 108 0.90 3.2 Capacity - 175 MWe 1973 127.1 263 146 70 76 0.56 1.1 1974 111.3 243 205 99 106 0.84 1.8 1975 145.1 82.4 210 138 62 16 78 60 0.66 1.0 1976 152.2 89.8 152 59 17 42 4
55 0.39 0.39 1977 124.6 73.9 725 356 28 328 174 182 0.49 2.86 ZION 1, 2 1974 425.3 71.1 306 56 13 43 0.18 0.2 Docket 50-295, -304; DPR-39, -48 1975 1181.5 74.9 1433 117 16 101 45 72 0.08 0.1 ist comercial operation 12/73, 1976 1134.9 61.9 774 571 64 507 257 314 0.74 0.50 m
m 9/74 1977 1358.6 75.0 784 1003 43 960 561 442 1.28 0.74 i
Type - PWR Capacity - 1010,1010 MWe Nu Q
LD C
4 CP
APPENDIX B LICENSED NUCLEAR POWER FACILITIES 1977 Whole Body Exposures 10 CFR Part 20.407 Data 2305 077
APPENDIX B LICENSED NUCLEAR POWER FACILITIES CY 1977 Whole Body Exposures (Per 10 CFR 20.407 Reports)
Exposure Ranges (Rems)
Total Total With Plant Name and No Measurable Measurable 0.10-0.25-0.50-0.75-1.0-2.0-3.0-4.0-5.0-6.0-7.0-8.0-9.0-Personnel Measurable License No.*
Exposure
<0.10 0.25 0.50 0.75 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Monitored Exposure Arkansas 1 247 251 116 78 43 33 63 16 1
848 601 DPR-51, PWR Beaver Valley 1 676 193 73 39 9
1 6
2 7
1 1,007 331 DPR-66 PWR Big Rock Point 28 213 53 33 23 16 61 46 4
9 2
2 Browns Ferry 1, 2 2,558 631 410 288 155 113 197 64 4,416 1,858 DFR-33.-52; BWR Brunswick 2 2,020 517 244 189 114 83 173 120 49 21 2
3,532 1,512 DPR-62. BWR rs y Calvert Cliffs 1 654 1,323 397 235 123 64 117 6
(,,4 O
(_71 Cook 1 1,190 386 130 82 56 59 82 7
%%J
- NOTE: Only those facilities which had completed at least one full year of commercial operation as of December 31, 1977 are included in this summary.
CD
APPENDIX B (Cont'd)
Exposure Ranges (Rems)
Total Total With Plant Name and No Measurable Measurable 0.10-0.25-0.50-0.75-1.0-2.0-3.0-4.0-5.0-6.0-7.0-8.0-9.0-Personnel Measurable License No.
Exposure
<0.10 0.25 0.50 0.75 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Monitored Exposure Cooper Station 783 117 39 35 34 18 52 13 7
1,098 315 DPR-46, BWR Dresden 1,2,3 DPR-10,-19.-25; BWR 1,059 493 296 210 165 110 277 188 102 19 2
2.921 1,862 Duane Arnold 636 180 78 73 63 39 87 18 1,174 538 DPR-49 BWR t
Fitzpatrick 650 260 232 241 146 114 257 104 18 7
1 2,030 1,380 0
DPR-59 BWR Fort Calhoun 58 248 44 58 45 36 75 20 7
2 593 535 DPR-40, PWR Ginna 147 112 70 79 52 48 145 22 2
677 530 DPR-18. PWR Haddam Neck 230 279 124 98 93 72 149 64 7
5 2
U Hatch 1 320 515 327 100 100 61 103 15 2
1,623 1,303 Q
( J'1 O
N
APPENDIX B (Cont'd)
Exposure Ranges (Rems)
Total Total With Plant Name and fio Measurable Measurable 0.10-0.25-0.50-0.75-1.0-2.0-3.0-4.0-5.0-6.0-7.0-8.0-9.0-Personnel Measurable License No.
Exposure
<0.10 0.25 0.50 0.75 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Monitored Exposure
' Humboldt Bay 85 157 72 72 56 43 212 204 155 92 1,148 1,063 a
DPR-7, BWR Indian Point 1,2,3b 607 333 255 235 143 92 173 88 54 16 2
1,998 1,391 DPR-5,-26; PWR Kewaunee 80 112 58 49 25 21 46 1
O Lacroste 64 38 21 5
5 3
16 21 15 11 6
205 441 DPR-45, BWR Maine Yankee 532 254 47 37 47 31 76 16 1,040 508 DPR-36 PWR Millstone Point 1c 290 537 236 li9 48 31 66 18 11 8
1 1,365 1,075 DPR-21. BWR Villstone Point 2c 130 333 147 74 30 19 41 11 7
O a Humboldt Bay was shutdown 7-2-77 for seismic modifications and did not operate the rest of the year.
(,.fi bIndian Point I was defueled in 1975. Unit 3 was shutdown 10 weeks at the end of 1977 for turbine repairs.
cPersonnel figures for Millstone Point Units 1 and 2 are approximations.
CD O
,.a e h e tl e ibr Wau 0
3 5
3 2
7 5
7 rs 6
9 9
7 3
2 7
1 l uo 8
0, 5,
6, 3
8, 8,
4 asp t ax 1
1 1
2 1
oeE TM ldee l nr ano 7
8 7
3 0
9 5
5 tot 9
0 7
5 6
9 2
28 osi 4,
0, 8,
8, 6
8, 1,
Trneo 1
2 1
1 3
2 PM
-0, 0 5
90 1
-00 3
1 89 0, 0, 4
2 78
-00 2
2 1
3 67 0
1 7
9 1
00 2
1 3
56
-00 8
0 1
6 3
9 5
2 1
1 5
45 1
5 9
0 8
7 1
1 0,. 0 3
2 5
3 4
1 1
34 1
-00 4
3 4
0 5
7 7
)
23, 7
6 7
2 8
2 4
1 1
1 1
1 2
)
s d
me
't R
00 5
7 2
8 8
8 6
0 n
(
6 4
6 5
1 9
7 1
o 12 1
3 2
4 4
2 1
C s
(
e g
B n
5 7,. 0, 9
6 5
5 5
1 2
6 a
4 7
2 2
1 7
1 2
X R I
01 1
1 1
1 D
e N
r E
u P
s 05 9
4 3
9 6
5 4
3 P
o 57 5
5 4
5 3
4 1
4 A
p 1
1 2
1 x
v0 E
-50 4
8 9
2 2
9 8
7 25 8
6 6
3 5
5 9
4 1
2 3
1 00
-05 6
3 5
5 2
3 6
6 12 9
9 0
1 6
0 4
5 2
2 4
2 00 e
lb0 a1 6
8 6
7 9
7 0
1 r,
8 1
6 9
4 9
2 7
u0 s<
1 2
4 2
1 8
3 ae M
e l
bae rr uu 7
5 2
0 8
2 0
8 ss 3
1 8
8 2
7 5
0 0,
2 4
ao 6
9 2
1 3
ep Mx 1
E o
N RW 1
P 3R 2, R dn.
t ao n
5, 2W W
N i
5 P
1P k
m e
o 3,
eR R
o; R
h; me R
PR as 7
eW W
t7 W
c7 N n low W
2, 4 1
B eB rB sP t2 B
a2 o,
e, C
e e
l l
t c e,
i,
1 m
B B
ni c2 M3 e8 r6 a0 4
i5.
d.
4 aL i2 6
e3 e1 s2 h2 r3 t2 l
t -
e-n -
t -
i -
c -
g -
n-P nR nR oR sR lR aR lR iR oP iP cP yP aP eP iP oP MD ND OD OD PD PD PD PD NUD Q-C
APPENDIX B (Cont'd)
Exposure Ranges (Rems)
I Total Total With Plant Name and No Measurable Measurable 0.10-0.25-0.50-0.75-1.0-2.0-3.0-4.0-5.0-6.0-7.0-8.0-9.0-Personnel Measurable License No.
Exposure
<0.10 0.25 0.50 0.75 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Monitored Exposure Prairie Island 1,2 231 297 140 98 62 37 63 15 6
949 718 DPR-42,-60; PWR Quad Cities 1,2 984 251 113 100 66 47 124 76 87 40 1
2 1,891 907 DPR-29.-30; BWR Rancho Seco 285 100 93 80 59 45 95 32 9
Robinson 2 696 264 87 50 46 35 86 28 23 14 1
1.330 634 DPR-23, PWR San Onofre 1 858 259 107 133 72 76 226 82 25 5
1,843 185 DPR-13, PWR St. Lucie R51 197 116 50 25 16 31 8
Ln Surry 1, 2 97 517 222 149 102 lil 338 194 115 48 28 19 8
8 1
1,957 1,860 g DPR-32,-27; PWR 00 N Three Mile Island 118 504 249 146 66 66 86 3
APPENDIX B (Cont'd)
Exposure Ranges (Rems)
Total Total With Plant Name and No Measurable Measurable 0.10-0.25-0.50-0.75-1.0-2.0-3.1-4.0-5.0-6.0-7.0-8.0-9.0-Personnel Measurable License No.
Exposure
<0.10 0.25 0.50 0.75 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Monitored Exposure Trojan 369 231 129 124 61 23 22 1
960 591 NPF-1, PWR Turkey Point 3,4 1,01 4 407 214 175 95 78 186 99 39 21 5
2,333 1,319 DPR-31.-41; PWR Vermont Yankee 535 292 80 86 64 50 59 10 1,176 641 DPR-28, 8WR Yankee Rowe 1,018 4?7 54 48 52 34 85 40 4
1 1,743 725 DPR-3, PWR Zion 1, 2 646 158 75 91 60 62 153 95 51 20 6
9 4
1,430 784 DPR-39 -43; PWR TOTALS 24,868 13,970 6,534 5,050 3,258 2,486 6,162 2,837 1,130 E69 141 66 36 21 6
67,134 42,266 l
l s
u O
LD C
CD u
APPENDIX C ANNUAL MA!;-REM
SUMMARY
Reg. Guide 1.16 Data Note: A "t" after a plant name indicates that licensee input was recategorized by NRC staff.
2305 084 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant: Arkansas 1 7 tal: 208.877 0
Total Man-Ren Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 8.063 0
0.127 Operations Personnel G3 0
Q Health Physics Personnel 6.748 0
0 Supervisory Personnel 0.656 0
0 Engineering Personnel 0
0 0
Routine Maintenance Maintenance Personnel 5.046 0.198 8.351 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0.136 Engineering Personnel 0
0 0
Inservice Inspection Maintenance Personnel 1.210 0
19.706 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 1.008 Engineering Personnel 0.634 0.209-0 Special Maintenance Maintenance Personnel 21.115 0.222 2n 172 Operations Personnel 0.958 0
0 Health Physics Personnel n.679 n
n Supervisory Personnel 0.244 0
1 nqq Engineering Personnel n_604 n
1 cnrs Waste Processing Maintenance Personnel 9.477 0.299 0
Operations Personnel 0.281 0
0 Health Physics Personnel 2.224 0
0.137 Supervisory Personnel 2.086 0
0 Engineering Personnel 0.841 0
0 Refueling Maintenance Personnal 26.714 0.840 13.409 Operations Personnel 10.)d4 0
0 Health Physics Personnel 4.989 0
8.904 Supervisory Personnel 3.527 0
0.916 Engineering Personnel 2.541 0.227 14.741 Totals Maintenance Personnel
.71.625 1.559 61.765 Operations Personnel 19.316 0
0 Health Physics Personnel 14.64 0
9.041 Supervisory Personnel 6.513 0
3.115 Engineering Personnel 4.62 0.436 16.247 Grand Totals - Man-Rems 116.714 1.995 90.168 2305 085 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant: Beaver Valley 1 Total: 65.522 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 0
0 n
Operations Personnel d.3%
0 n
Health Physics Personnel QJ05 0
n Supervisory Personnci
- 9. lfi0 0
n_11n
_ Engineering Personnel 0
0 n
Routine Maintenance Maintenance Personnel 8.393 1.175 1.655 Operations Personnel 0
0 0
Health Physics Personnel 5.190 0
0 Supervisory Personnel 0.875 0
0 Engineering Personnel 0
0 0
Inservice Inspection Maintenance Personnel 0
0 0
Operations Personnel 0
0-0 Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0.360 0
0 Special Maintenance Maintenance Personnel 0
0 41.750 Operations Personnel 0
0 0
Health Physics Personnel 0.130 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 0.110 0
0 Waste Processing Maintenance Personnel 0
0 0.130 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Totals Maintenance Personnel 8.393 1.175 43.535 Operations Personnel 5.389 0
0 Health Physics Personnel 5.425 0
0 Supervisory Personnel 1.025 0
0.110 Engineering Personnel 0.47 0
0 Grand Totals - Man-Rems 20.702 1.175 43.645 2305 086 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING Of MAN-REM BY WORK AND JOB FUNCTION Plant: Big Rock Point Total: 353.147 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 2.016 4.178 1.082 Operations Personnel 33.583 0.603
_0 Health Physics Personnel 42J35 1.143 0
Supervisory Personnel 11.574 0
0 Engineering Personnel 1.746 0.451 0
Routine Maintenance M31ntenance Personnel 48.124 77.007 22.357 Operations Personnel 5.780 2.098 0
Health Physics Personnel 8.946 0
0 Supervisory Personnel 9.546 1.325 8.000 Engineering Personnel 7.275 0.104 0
Inservice Inspection Maintenance Personnel 3.204 4.009 17.887 Operations Personnel 0.291 5.741 0
Health Physics Personnel 0.893 0
0 0.837 0
0 Super.isory Personnel Engineering Personnel 3.350 0
0 Special Maintenance Maintenance Personnel 4.301 0
0.364 Operations Personnel 0.819 0
0 Health Physics Personnel 0.787 0
0 Supervisory Personnel 0.373 0
0 Engineering Personnel 0.055 0
0 Waste Processing Maintenance Personnel 0.939 0.142 1.044 Operations Personnel 1.778 0
0 Health Physics Personnel 0.447 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0.215 0
11.076 Operations Personnel 3.048 0
0 Health Physics Personnel 0.024 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Totals Maintenance Personnel 58.849 85.336 55.81 Operations Personnel 45.299 8.442 0
Health Physics Personnel 53.576 1.143 0
Supervisory Personnel 22.386 1.325 8.000 Engineering Personnel 12.426 0.555 0
Grand Totals - Man-Rems 192.536 96.801 63.81 2305 087 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant: Browns Ferry 1. 2 4tal-679.9 Total Man-Rem Station Utfli ty Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 11.3 15.3 0
Operations Personnel 6.7 0
0 Health Physics Personnel 4.7 0.4 0
Supervisory Personnel 0
0 0
Engineering Personnel 0.6 5.4 3.0 Routine Maintenance Maintenance Personnel 56.3 202.9 2.6 Operations Personnel 1.2 0
0 Health Physics Personnel 5.9 0.9 0.2 Supervisory Personnel 0
0 0
Engineering Personnel 0.6 11.1 11.9 Inservice Inspection Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Special Maintenance Maintenance Personnel 8.8 98.8 2.9 Operations Personnel 3.1 0
0 Health Physics Personnel 1.5 0.6 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
28.1 175.4 Waste Processing Maintenance Personnel 0
0 0
0 0
Operations Personnel 0.2 Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
14.5 0
Operations Personnel 4.0 0
0 Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
1.1 0
Totals Maintenance Personnel 76.4 331.5 5.5 Operations Personnel 15.2 0
0 Health Physics Personnel 12.1 1.9 0.7 Supervisory Personnel 0
0 0
Engineering Personnel 1.2 45.7 190.2 Grand Totals - Man-Rems 104 9 379.1 195.9 2305 088 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant: Brunswick 1 t Total: 1086.082 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel i.286 0
0.228 Operations Personnel 33.935 0
0.090 Health Physics Personnel 5.587 0.388 0
Supervisory Personnel 1.335 C
0 Engineering Personnel 2.747 0.315 0.450 Routine Maintenance Maintenance Personnel 26.691 3.516 47.117 Operations Personnel 0
0 0
Health Physics Personnel 2.352 0.388 1. 511 Supervisory Personnel 0
0 0
Engineering Personnel 2.747 0.316 0
Inservice Inspection Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 4.534 Supervisory Personnel 0
0.771 0
Engineering Personnel 9.620 1.969 57.760 Special Maintenance Maintenance Personnel 67.118
- 33.469 415.566
- Operations Personnel 0
0 0
Health Physics Personnel 12.939
- 3.680
- 16.626
- Supervisory Personnel 0
0.823 0
Engineering Personns?
10.987 0.425 6.171 Waste Processing Maintenance Personnel 21.637 0
97.708
- Operations Personnel 28.279 0
0 Health Physics Personnel 6.175 0.388 3.023 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 1.349 Refueling Maintenance Personnel 10.496 0
97.999 Operations Personnel 32.050 0
0 Health Physics Personnel 2.352 0.388 4.534 Supervisory Personnel 0
0 0
Engineering Personnel 1.831 0
4.416 Totals Maintenance Personnel 127.228 36.985 658.618 Operations Personnel 94.264 0
0.09 Health Physics Personnel 29.405 5.232 30.228 Supervisory Personnel 1.335 1.594 0
Engineering Personnel 27.932 3.025 70.146 Grand Totals - Man-Rems 280.164 46.836 759.082
- Includes exposures reported under "deconnina" by licensee.
230S 089 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant: Calvert Cliffs 1 T914]: 401.614 Total Man-Rem Station Utili ty Contract Work and Job Function Employees Enployees Employees Reactor Operations & Surveillance Maintenance Personnel 0.823 0.101 3.092 Operations Personnel 7.82T 0
0 Health Physics Personnel 4.805 0.632 4 Afn Supervisory Personnel 3.868 0
0102 Engineering Personnel 0.503 0
0 Routine Maintenance Maintenance Personnel 15.486 0.805 3.528 Operations Personnel 5.051 0.712 0
Health Physics Personnel 7.884 0
1.688 Supervisory Personnel 1.8T6 0
0.491 Engineering Personnel
- 0. T42 0
0.274 Inservice Inspection Maintenance Personnel 1.777 38.404 9.450 Operations Personnel 0.253 0
0 Health Physics Personnel 0.341 0
0.112 Supervisory Personnel 0
0 0.129 Engineering Personnel 0
0 0
Special Maintenance Maintenance Personnel 46.551 39.735 97.790 7
Operations Personnel 2.017 2.916 0.2 31 Health Physics Personnel 7.606 2.175 22.609 Supervisory Personnel 0.676 0.656 1.837 Engineering Personnel 0.795 1.619 4.432 Waste Processing Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0.277 0.686 1.050 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 24.971 10.407 6.585 Operations Personnel 0.584 0.320 0
Health Physics Personnel 2.036 0.915 2.200 Supervisory Personnel 0.215 0.107 0
Engineering Personnel 0.129 0
3.723 Totals Maintenance Personnel 89.608 89.452 120.445 Operations Personnel 15.757 3.948 0.231 Health Physics Personnel 22.949 4.408 32.222 Supervisory Personnel 6.555 0.763 3.059 Engineering Carsonnel 2.169 1.61 9 8.429 Grand Totals - Man-Rems 137.038 100.19 164.386 2305 090 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant: Cook 1 Totcl: 260.356 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 0.947 0
0.060 Operations Personnel 13.245 0
0.384 Health Physics Personnel 2.149 0
0.177 Supervisory Personnel 0.956 0
0 Engineering Personnel 0.152 0
0 Routine Maintenance l'aintenance Personnel 53.127 0
2.867 Operations Personnel 0.419 0
0 Health Physics Personnel 3.503 0
0 Supervisory Personnel 2.012 0
0 Engineering Personnel 0.640 0
0.284 Inservice Inspection Maintenance Personnel 8d23 0
49 151 Operations Personnel 0
0 n
Health Physics Personnel 0.010 0
6.74R Supervisory Personnel 0.080 0
1 6g2 Engineering Personnel 0.302 0
0.117 Special Maintenance Maintenance Personnel 11.168 0
15.277 Operations Personnel 0.212 0
0 Health Physics Personnel 1.825 0
0.309 Supervisory Personnel 0.600 0
0.328 Engineering Personnel 1.552 0
0.184 Waste Processing Maintenance Personnel 11.001 0
16.119 Operations Personnel 4.510 0
0 Health Physics Personnel 3.814 0
0 Supervisory Personnel 0.343 0
0 Engineering Personnel 0.126 0
0 Refueling Maintenance Personnel 16.356 0
19.747 Operations Personnel 0.029 0
0 Health Physics Personnel 0.160 0
4.498 Supervisory Personnel 2.752 0
1.757 Engineering Personnel 0.344 0
0 Totals Maintenance Personnel 100.722 0
103.221 Operations Personnel 18.415 0
0.384 Health Physics Personnel 11.461 0
11.712 Supervisory Personnel 6.743 0
1.777 Engineering Personnel 3.116 0
0.7P5 Grand Totals - Man-Rems 140.457 0
119.899 2305 091 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant: Cooper Total: 195.111 Total Man-Rem
' Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 1.130 0
0.220 Operations Personnel 26.964 0
0 Health Physics Personnel 7.633 0
0 Supervisory Personnel 8.524 0
0 Engineering Personnel 4.284 1.175 0
Routine Maintenance Maintenance Personnel 53.488 0
39.187 Operations Personnel 1.03) 0 0
Health Physics Personnel 2,JJ 8 0
0 Supervisory Personnel 1.055 0
0.075 Engineering Personnel 1. 31 0 0
0 Inservice Inspection Maintenance Personnel 0.244 0
2.613 Operations Personnel 0J67 0
0 Health Physics Personnel 1.003 0
0 Supervisory Personnel 0
Q 7.060 Engineering Personnel 0.200 0
0 Special Maintenance Maintenance Personnel 2.424 0
13.479 Operations Personnel 0J93 0
0 Health Physics Personnel 0.638 0
0 Supervisory Personnel 0.109 0
1.605 Engineering Personnel 0.910 0
0 Waste Processino Maintenance Personnel 1.561 0
0 Operations Personnel 2.248 0
0 Health Physics Personnel 1.415 0
0 Supervisory Personnel 0.012 0
0 Engineering Personnel 0
0 0
Refueling Maintenance Personnel 3.067 0
1.203 Operations Personnel 5.617 0
0 Health Physics Personnel 0.776 0
0 Supervisory Personnel 0.199 0
0 Engineering Personnel 0.111 0
0 Totals Maintenance Personnel 62.014 0
56,702 Operations Personnel 36.122 0
0 Health Physics Personnel 13.583 0
0 Supervisory Personnel 9.900 0
8.740 Engineering Personnel 6.875 1.175 0
Grand Totals - Man-Rems 128.494 1.175 65.442 2305 092 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK ANC.10B FUNCTION Plant:
Dresden 1. 2. 3 Total: 1634.9 Total Man-Rem Station Utility Contract Work and Job Function Employees Emplo_yees Employees Reactor Operations & Surveillance Maintenance Personnel 9.7 0
0 Operations Personnel 7 D7.0 0
~
0 Health Physics Personnel 26.3 0
0 Supervisory Personnel 16.4 0
0 Engineering Personnel 46.2 0
0 Routine Maintenance
- Maintenance Personnel 321.7 0
669.2 Operations Personnel 24.7 0
0 Health Physics Personnel
_ 121.2 0
0 49.4 0
0 Supervisory Personnel Engineering Personnel 0
0 0
Inservice Inspection Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Special Maintenance Maintenance Personnel 0
46.0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Waste Processing Maintenance Personnel 0
0 0
Operations Personnel 48.2 0
0 Health Physics Personnel 63 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
0 0
Operations Personnel 38.8 0
0 Health Physics Personnel 0
0 0
Supervisory Personnel 4.2 0
0 Engineering Personnel 0
0 0
Totals Maintenance Personnel 330.7 46.0 669.2 Operations Personnel 318.7 0
0 Health Physics Personnel 82.3 0
0 Supervisory Personnel 141.8 0
0 Engineering Personnel 46.2 0
0 Grand Totals - Man-Rems 414 7 46.0 669.2
- Includes Inservice Inspection Exposures.
APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant: Duane Arnold Total: 274.779 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Paintenance Personnel 5.204 0
0 Operations Personnel 18.922 0
0 Health Physics Personnel 1.847 0
0 Supervisory Personnel 3.9Ti 0
0 Engineering Personnel 2.172 0.234 0.412 Routine Maintenance Maintenance Personnel 11.002 0
0 Operations Personnel 0
0 0
Health Physics Personnel 2.719 0
0 Supervisory Personnel 0.5B5 0
0 Engineering Personnel 0.053 0.124 0
Inse vice Inspection Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 6.245 Special Maintenance Maintenance Personnel 7.607 0
182.130 Operations Personnel 0.224 0
0 Health Physics Personnel 0.204 0
8.244 Supervisory Personnel 0.086 0
0 Engineering Personnel 0.348 2.592 4.636 Waste Processing Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 10.589 0
0 Supervisory Personnel 0.141 0
0 Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
0 0
Operations Personnel 2.055 0
0 Health Physics Personnel 0
0 1.5 31 Supervisory Personnel 0.882 0
0 Engineering Personnel 0
0 0
Totals Maintenance Personnel 23.813 0
182.130 Operations Personnel 21.201 0
0 Health Physics Personnel 15.359 0
9.77E Supervisory Personnel 5.685 0
0 Engineering Personnel 2.573 __
2.95 11.293 Grand Totals - Man-Rems 68.631 2.95 203.198 2305 094 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Fitzpatrick i Total: 948.752 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 1.308 0.049 5.153 Operations Personnel 3.225 0
0.025 Healtn Physics Personnel 0.121 0
0.480 Supervisory Personnel 0.994 0
0.136 Engineering Personnel 0.043 0.022 0.438 Routine Maintenance Maintenance Personnel 12.365 0.466 71.307 Operations Personnel 1.563 0
0.149 Health Physics Personnel 1.232 0
0.561 Supervisory Personnel 1.636 0
0.780 Engineering Personnel 0.427 0
3.934 Inservice Inspection Maintenance Personnel 0.389 0.072 10.857 Operations Personnel 0.553 n
n.nns Health Physics Personnel 0.284 0
1.108 Supervisory Personnel 0.657 0
0.404 Engineering Personnel 0.070 0
3.636 Special Maintenance Maintenance Personnel 41.152 3.709 628.517 Operations Personnel 13.684 0
1.009 Health Physics Personnel 3.640 0
9.081 Supervisory Personnel 9.013 0.113 6.436 Engineering Personnel 3.327 0.030 39.594 Waste Processing Maintenance Personnel 3.470 0.11 34.517 Operations Personnel 12.184 0
0.055 Health Physics Personnel 1.221 0
0.371 Supervisory Personnel 0.462 0
0.378 Engineering Personnel 0.06 0.005 0.285 Refueling Maintenance Personnel 5.129 n.745 1.171 Operations Personnel 1.044 n
n Health Physics Personnel 0.297 n
n 119 Supervisory Personnel n.6?R n
n n?a Engineering Personnel n.179 0
n_RR; Totals Maintenance Personnel 61 R11 a 6a1 751 517 Operations Personnel 12.251 n
1 2a1 Health Physics Personnel 6 700 n
19 nao Supervisory Personnel 11_lo n 111 8 159 Engineering Personnel a ans n_ns7 zo a79 Grand Totals - Man-Rems 120.552 4.771 823.429 4
2305 095 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
Fort Calhoun Total: 355.939 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations A Surveillance Maintenance Persormel 3.577 0_.663 3.116 Operations Personr.el 12.735 0.020 0
Health Physics Personnel 10.131 0.483 4.749 Supervisory Personnel 1.116 0.189 0
Engineering Personnel 1.846 1.440 0
Routine Maintenance Maintenance Personnel 18.335 8.779 5.475 Operations Personnel 0.115 0
0 Health Physics Personnel 0.121 0.100 0
Supervisory Personnel 0320 0.029 0
Engineering Personnel 0.169 0 208 0
Inservice Inspection Maintenance Personnel 2.138 9.425 18.360 Operations Personnel
- 0. 01 0 0
0 Health Physics Personnel 0.051 0
0.040 Supervisory Personnel 0.040 0.093 0
Engir.eering Personnel 0 515 0.984 0
~
Special Maintenance Maintenance Personnel 33.250 17.111 14 447 Operations Personnel n 013 n.nns n
Health Physics Personnel 4.280 n.024 n
Supervisory Personnel n.691 0.036 n
Engineering Personn_el 3.JRQ n R2n n
Waste Processing Maintenance Personnel 15.599 9.812 2.451 Operations Personnel 3.665 0
0 Health Physics Personnel M 67 0.005 0.110 Supervisory Personnel 0.143 0
n Engineering Personnel 0 ??9 0.015 0
Refueling Maintenance Personnel 19.973 53.731 26.158 Operations Personnel 11.152 0
0 Health Physics Personnel 1.354 0.135 10.734 Supervisory Personnel 4.977 1.213 0
Engineering Personnel 4.388 5.821 0
Totals Maintenance Personnel 92.872 99.743 70.554 Operations Personnel 28.590 0.025 0
Health Physics Personnel 19.404 0.747 15.611 Supervisory Personnel 7.087 1.560 0
Engineering Personnel 10.436 9.288 0
Grand Totals - Man-Rems 158.389 111.363 86.187 2305 096 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Ginna Total: 371.29 Total Man-Rem Station Utili ty Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 2.45 0
0 Operations Personnel 11.05 0
0 Health Physics Personnel O
G 0
Supervisory Personnel 0
0 0
Engineering Personnel _
0 0
0 Routine Maintenance Maintenance Personnel 30.59 83.40 63.51 Operations Personnel 0
0 0
Health Physics Personnel 6.53 0.27 2.48 Supervisory Personnel 1.73 1.50 0
Engineering Personnel 1.05 2.50 0
Inservice Inspcction Maintenance Personnel 0.50 3.40 2.40 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Special Maintenance Maintenance Personnel 1.50 7.50 22.59 Operations Personnel 0
0 0
Health Physics Fersonnel 0.60 0
1.00 Supervisory Personnel 0
0 0.50 Engineering Personnel 0
0 0.50 Waste Processing Maintenance Personnel 8.00 0
15.00 Operations Personnel 9.50 0
0 Health Physics Personnel 3.50 0
1.20 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
75.60 1.20 Operations Personnel 4.45 0
0 Health Physics Personnel 0.50 0
0.50 Supervisory Personnel 0
2.50 0
Engineering Personnel 1.79 0
0 Totals Maintenance Personnel 43.04 169.40 104 7 Operations Personnel 25.00 0
n Health Physics Personnel 11.11 n.27 g in Supervisory Personnel 1.73 4 00 n En Engineering Personnel 2.no 2_;n n En Grand Totals - Man-Rems 83.74 176.67 110.88 2305 097 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
Haddam Neck Total: 708.698 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 3.722 0.503 2.760 Operations Personnel 32.824 0
0 Health Physics Personnel 12.365 0.005 4.360 Supervisory Personnel 2.816 0.5E0 2.288 Engineering Personnel 0.738 2.081 0.080 Routine Maintenance Maintenance Personnel 30.881 48.733 14.775 Operations Personnel 1.397 0
0 Health Physics Personnel 0.830 0
9.135 Supervisory Personnel 4.245 0.065 1.787 Engineering Personnel 3.022 1.993 0.538 Inservice Inspection Maintenance Personnel 0.795 1.525 18.545 Operations Personnel 0.430 0
0 Health Physics Personnel 0.100 0
0 Supervisory Personnel 0.165 0
0.060 Engineering Personnel 0.485 1.504 0.675 Special Maintenance Maintenance Personnel 7.138 8.61 3 235.075 Operations Personnel 1.500 0
0 Health Physics Personnel 0.640 0.005 11.245 Supervisory Personnel 0.410 0.830 21.086 Engineering Personnel 0.205 2.778 2.683 Waste Processing Maintenance Personnel 0.445 0.335 1.941 Operations Personnel 1.997 0
0 Health Physics Personnel 0.635 0
19.186 Supervisory Personnel 0.030 0
0.680 Engineering Personnel 0.035 0
0.045 Refueling Maintenance Personnel 6.877 20.591 111.674 Operations Personnel 11.447 0
0 Health Physics Personnel 0.905 0.970 18.135 Supervisory Personnel 0.965 0.195 8.370 Engineering Personnel 1.210 1.630 1.415 Totals Maintenance Personnel 49.858 80.3 384.77 Operations Personnel 49.595 0_
0 Health Physics Personnel 15.475 0.98 62.061 Supervisory Personnel 8.631 1.64
, 34.271 Engineering Personnel 5.695 9.986 5.436 Grand Totals - Man-Rems 129.254 92.906 486.533 2305 098 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Hatch 1 Total: 431 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel
- 0 3
0 Operations Personnel 53 0
0 Health Physics Personnel 15 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 5
0 13 Routine Maintenance Maintenance Personnel
- 70 0
0 Operations Personnel 18 0
0 Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Inservice Inspection Maintenance Personnel
- 0 0
0 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 67 Special Maintenance Maintenance Personnel
- 28 14 0
Operations Personnel 14 0
0 Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 97 Waste Processing Maintenance Personnel
- 0 0
0 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel
- 7 0
0 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 27 Totals Maintenance Personnel
- 105 17 0
Operatio.
Personnel 85 0
0 Health Physics Personnel 15 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 5
0 204 Grand Totals - Man-Rems 210 17 204
- Maintenance data includes information reported as Construction exposures.
- 305 099 9
APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
Humboldt Bay Total: 1857 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 0
0 0
Operations Personnel 16 0
0 Health Physics Personnel 1
0 0
Supervisory Personnel 3
0 2
Engineering Personnel 1
0 0
Routine Maintenance Maintenance Personnel 33 6
1 Operations Personnel 0
0 0
Health Physics Personnel 3
0 0
Supervisory Personnel 1
0 0
Engineering Personnel 1
0 0
Inservice Inspection Maintenance Personnel 0
3 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
1 0
Special Maintenance Maintenance Personnel 11 719 865 Operations Personnel 2
0 0
Health Physics Personnel 2
2 55 Supervisory Personnel 3
25 23 Engineering Personnel 5
32 3
Waste Processing Maintenance Personnel 0
0 0
Operations Personnel 9
0 0
Health Physics Personnel 1
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
0 0
Operations Personnel 25 0
0 Health Physics Personnel 0
0 0
Supervisory Personnel 2
0 0
Enginee-ing Personnel 1
0 0
Totals Maintenance Personnel 44 728 866 Operations Personnel 52 0
0 Health Physics Personnel 7
2 55 Supervisory Personnel g
25 25 Engineering Personnel n
11 7
Grand Totals - Man-Rems 120 7AR gag 4-APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
Indian Point 1, 2, 3*
"otal: 964.7 Total ian-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance 170.7 0
0 Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Routine Maintenance 146.1 0
n Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Inservice Inspection 0
0 n
Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Special Maintenance 6.6 1Rg 5 111 A Maintenance Personnei Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Waste Processing 106.8 0
11 A Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Refueling 0
0 0
Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Totals Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Grand Totals - Man-Rems 430.2 189.5 345.0
- Breakdown by Job Function not provided by licensee.
2305 101
~
APPENDIX C STANDARD FORMAT FOR ANNUAL REPORl:NG OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Kewaunee Total: 130.689 Total Man-Rem Station Utility Contract Work and Job Function Empicyees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 0
0 0
Operations Personnel 6.629 0
0 Health Physics Personnel 0
0 0
Supervisory Personnel 1.127 0
0.010 Engineering Personnel 0.216 0
0 Routine Maintenance Maintenance Personnel 5.371 2.889 33.448 Operations Personnel 0.015 0
0 Health Physics Personnel 2.508 0
4.399 Supervisory Personnel 0
0.020 0.858 Engineering Personnel 0
0 0
Inservice Inspection Maintenance Personnel 0
0 2.405 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0.240 0.807 Engineering Personnel 0
0.019 0
Special Maintenance Maintenance Personnel 10.650 10.082 11.714 Operations Personnel 0.613 0
0 Health Physics Personnel 2.641 0
0 Supervisory Personnel 0.432 0.236 0.634 Engineering Personnel 0.169 0.043 0.528 Waste Processing Maintenance Personnel 1.163 0
0.480 Operations Personnel 1.300 0
0 Health Physics Personnel 3.002 0
0 Supervisory Personnel 0.889 0
0 Engineering Personnel 0
0 0
Refueling Maintenance Personnel 2.194 3.844 16.247 Operations Personnel 1.558 0
0 Health Physics Personnel 0.100 0
0 Supervisory Personnel 0.722 0.230 0.124 Engineering Personnel 0
0.133 0
Totals Maintenance Personnel 19.378 16.815 64.294 Operations Personnel 10.115 0
0 Health Physics Personnel 8.251 0
4.399 Supervisory Personnel 3.170 0.726 2.433 Engineering Personnel 0.385 0.195 0.528 Grand Totals - Man-Rems 41.299 17.736 71.654 2305 102 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Lacrosse Total: 217.017 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 1.137 0
0 Operations Personnel 37.692 0
1.889 Health Physics Personnel 7.157 0
0 Supervisory Personnel 9.858 0
0 Engineering Personnel 0.791 0
0 Routine Maintenance Maintenance Personnel 13.522 0
0 Operations Personnel 7.562 0
0 Health Physics Personnel 5.424 0
0 Supervisory Personnel 4.025 0
0 Engineering Personnel 4.059 0
0 Inservice Inspection Maintenance Personnel 0.191 0
0 Operations Personnel 0.220 0
0 Health Physics Personnel 0
0 0
Supervisory Personnel 1.293 0
0 Engineering Personnel 0.139 0
3.132 Special Maintenance Maintenance Personnel 58.361 0
1.108 Operations Personnel 6.104 0
0 Health Physics Personnel 10.951 0
0 Supervisory Personnel 6.480 0
0 Engineering Personnel 4.590 0
1.125 Waste Processing Maintenance Personnel 2.539 0
0 Operations Personnel 1.040 0
0 Health Physics Personnel 7.791 0
0.618 Supervisory Personnel 2.747 0
0 Engine? ring Personnel 1.011 0
0 Refueling Maintenance Personnel 1.459 0
0 Operations Personnel 5.890 0
0 Health Physics Personnel 1.750 0
0 Supervisory Personnel 3.330 0
0 Engineering Personnel 2.032 0
0 Totals Maintenance Personnel 77.209 0
1.108 Operations Personnel 58.508 0
1.889 Health Physics Personnel 33.073 0
0.618 Supervisory Personnel 27.733 0
0 Engineering Personnel 12.622 0
4.257 Grand Totals.- Man-Rems 209.145 0
7.872 2305 103 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WnRK AND JOB FUNCTION Plant:
Maine Yankee Total: 301.070 Tctal Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 2.089 0
n 974 Operations Personnel 20.449 0
n Health Physics Personnel 8.784 0
0 ans Supervisory Personnel 9.345 1.807 2 nas Engineering Personnel 7.828 1.289 n n?1 Routine Maintenance Maintenance Personnel 29.280 0.020 n s?s Operations Personnel 0
0 n
Health Physics Personnel 0
0 n
Supervisory Personnel 0.563 0.330 4.94n Engineering Personnel 0.077 0
P 01n Inservice Inspection Maintenance Personnel 8JD5 0.n2n 11.477 Operations Personnel 1.431 0
0 Health Physics Personnel 0.220 0
n.125 Supervisory Personnel 0.463 0.490 19.24?
Engineering Personnel 1.402 0.470 15.329 Special Maintenance Maintenance Personnel 1.040 0
0 Operations Personnel Qt190 0
0 Health Physics Personnel 0.050 0
0 Supervisory Personnel 0
0 1.496 Engineering Personnel 0,035 0.015 0.020 Waste Processing Maintenance Personnel 0.818 0
0.080 Operations Personnel 1.569 0
0 Health Physics Personnel 0.040 0
0.566 Supervisory Personnel 0.070 0.012 0.390 Engineering Personnel 0.070 0
0 Refueling Maintenance Personnel 35.017 0.54R 76.765 Operations Personnel 17.298 0
n Health Physics Personnel 1.812 n
s_no1 Supervisory Personnel 2.ns1 1 los at int Engineering Personnel 5.765 1.167 n An?
Totals Maintenance Personnel 76 549 n Enn 49 ini Operations Personnel an.417 n
n Health Physics Personnel in ong n
g 1r Supervisory Personnel 12 aq9 1 c7s 79 n7a Engineering Personnel 1s 177 9 cat is ng?
Grand Totals - Man-Rems 156.061 7.504 137.506 2305 104 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Millstone 1 Total: 349.977 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 9.310 0.015 17.317 Operations Personnel 46.835 0
0.055 Health Physics Personnel 10.365 0
5.415 Supervisory Personnel 12.715 0.015 1.585 Engineering Personnel 0.285 0.245 1.000 Routine Maintenance Maintenance Personnel 21.205 0.590 8.900 Operations Personnel 0.605 0
0 Health Physics Personnel 0.345 0
0.075 Supervisory Personnel 0.430 0
0.100 Engineering Personnel 0.270 0.195 0.215 Inservice Inspection Maintenance Personnel 0.040 0.015 0.090 Operations Personnel 0.035 0
0 Health Physics Personnel 0.040 0
0 Supervisory Personnel 0.095 0.010 0.040 Engineering Personnel 0.130 0.145 0.100 Special Maintenance Maintenance Personnel 66.066 1.545 67.735 Operations Personnel 2.425 0
0 Health Physics Personnel 1.190 0
1.040 Supervisory Personnel 2.81 0 0.210 4.465 Engineering Personnel 2.595 4.375 4.424 Waste Processing Maintenance Personnel 6.040 0.045 17.025 Operations Personnel 12.665 0
0 Health Physics Personnel 2.230 0
1.440 Supervisory Personnel 0.850 0
2.615 Engineering Personnel 0.090 0.160 2.260 Refueling Naintenance Personnel 0.285 0
3.235 Operations Personnel 0.310 0
0 riealth Physics Personnel 0.030 0
0.180 Supervisory Personnel 0
0.005 0.920 Engineering Personnel 0.200 0.065 1.600 Totals Maintenance Personnel 102.946 2.21 114.302 Operations Personnel 62.875 0
0.055 Health Physics Personnel 14.200 0
8.170 Supervisory Personnel 16.900 0.24 9.725 Engineering Personnel 3.570 5.185 9.599 Grand Totals - Man-Rems 200.491 7.635 141.851 N
2305 105 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant: Millstone 2 Total: 216.85 lotal Man-Rem Station UtiTi ty contract Work and Job function Employees Employees Emoloyees Reac+or Operations & Surveillance Maintenanca Personnel 0.655 0.030 3.820 Operations Personnel 9.684 0.005 0.060 Health Physics Personnel 4.835 0.0T6 9.312 Supervisory Personnel 1.465 0
0.385 Engineering Personnel 0.955 0.110 2.430 Routine Maintenance Maintenance Personnel 3.100 2.490 1.835 Operations Personnel 1.3HD 0
0 Health Physics Personnel 0.1 50 0
0.075 Supervisory Personnel 0]0 0
0.065 Engineering Personnel 0.070 0.140 0.690 Inservice Inspection Maintenance Personnel 2.309 2.153 11.393 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0.139 0
2.205 Engineering Personnel 0.185 0.435 9.843 Special Maintenance Maintenance Personnel 20.109 14.995 59,040 Operations Personnel 0J50 0
0 Health Physics Personnel 0.53_0 0
0.720 Supervisory Personnel 0J5 0.010 5.345 Engineering Personne) 0.980 2.J05 15.998 Waste Processing Maintenance Personnel 0.155 0
1.255 Operations Personnel 1.060 0
0 Health Physics Personnel 0.610 0
0 Supervisory Personnel 0.330 0
0 Engineering Personnel 0.040 0
0.050 Refueling Maintenance Personnel 6.015 0.205 11.960 Operations Personnel 0.700 0
0 Health Physics Personnel 0.010 0
0 Supervisory Personnel 0.180 0.000 0.520 Engineering Personnel 0.2%
0.0I0 0.795 Totals Maintenance Personnel J 2.343 ljL873 89.303 Operations Personnel 13.474 0.005 0.060 Health Physics Personnel 6.165 0.010 10.107 Supervisory Personnel 2.529 0.030 8.52 Engineering Personnel 2.525 2.700 2g 20f>
Grand Totals - Man-Rems 57.036 22.618 137.196 2305 106 m
.e, APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant: Monticello "glal 906.944 Total ian-Rem Station Utili ty Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maint enance Personnel
~ 65.773 0
0 8.056 0
0 Operations Personnel Health Physics Personnel 15.415 0
n Supervisory Personnel 9.901 3.331 t Ap7 Engineering Personnel 9.901 3.331 1.4P6 Routine Maintenance Maintenance Personnel 51.963 28.871 0.22n Operations Personnel 0
0 0
HeL l u, Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Inservice Inspection Maintenance Personnel 0
0 0
Operations Personnel 0
0 18.567 Health Physics Personnel 0
0 0.447 Supervisory Personnel 0
0.257 1.883 Engineering Personnel 0
0.258 1.883 Special Maintenance Maintenance Personnel 35.533 57.436 526.019 Operations Personnel 0
0 0
Health Physics Personnel 1.760 0
31.365 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Waste Processing Maintenance Personnel 5.157 0
0 Operations Personnel 3.977 0
6.364 Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0.711 1.642 0.238 Operations Personnel 4.161 0
0.390 Health Physics Personnel 0
0 1.371 Supervisory Personnel 0
0 2,905
- Engineering Personnel 0
0 0.885 Totals Maintenance Personnel 101.420 87.949.
526.477 Operations Personnel 73.911 0
25.121 Health Physics Personnel 17.175 0
11.194 Supervisory Personnel 9.901 3.588 R.279 Engineering Personnel 9.901 3.589 6 2s1 Grand Totals - Man-Rems 212.10R 95.126 soo sin
- Includ?s exposures reported under ' Security' by licensee.
2305 107
,72 -
APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-RFM BY WORK AND JOB FUNCTION Plant:
Nine Mile Point I t Total: 1313.754 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 13.596 4.332 2.156 Operations Personnel 4.385 0
0 Health Physics Personnel 8.226 0.008 0.083 Supervisory Personnel 3.531 0.050 0.523 Engineering Personnel 0.399 0.505 0.841 Routine Maintenance Maintenance Personnel 10.63 1.111 1.153 Operations Personnel 0.535 0
0 Health Physics Personnel 0.620 0
0.280 Supervisory Personnel 0334 0.01 0 0.055 Engineering Personnel 0.155 0.028 0.457 Inservice Inspection Maintenance Personnel 6.931 9.584 24.319 Operations Personnel 0.105 0
0 Health Physics Personnel 1.222 0.020 0
Supervisory Personnel 3.382 0.060 1.328 Engineering Personnel 1.980 0.917 2.715 Special Maintenance Maintenance Personnel 130.221 132.704 688.565 Operations Personnel 5.382 0
0 Health Physics Personnel 11.918 0.277 4.456 Supervisory Personnel 8.23 1.422 81.017 Engineering Personnel 3.468 9.104 13.577 Waste Processing Maintenance Personnel 29.484 8.085 2.856 Operations Personnel 13.242 0
0 Health Physics Personnel 3.267 0
0.115 Supervisory Personnel 2.084 0
0.040 Engineering Personnel 0
0.053 0.651 Refueling Maintenance Personnel 19.429 15.362 11.523 Operations Personnel 2.836 0
0 Health Physics Personnel 1.403 0.171 0.407 Supervisory Personnel 2.564 0.240 0.008 Engineering Personnel 0.629 0.968 1.23 Totals Maintenance Personnel 210.291 171.178 730.572 Operations Personnel 26.485 0
0 Health Physics Personnel 26.656 0.476 5.341 Supervisory Personnel 20.325 1.782 82.971 Engineering Personnel 6.631 11.575 19.471 Grand Totals - Man-Rems 290.388 185.011 838.355 2305 108 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant: Oconee 1, 2, 3 Total: 1331.555 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 32.270 42.685 18.055 Operations Personnel 71390 0.565 0
Health Physics Personnel 29.43D 0.820 7.355 Supervisory Personnel 1.135 0.150 0.230 Engineering Personnel 34.505 3.085 2.835 Routine Maintenance Maintenance Personnel 43.825 1 E 925 8.500 Operations Personnel 13.635 0
0 Health Physics Personnel 2.485 0.335 3.220 Supervisory Per. 'nnel 2.365 0.030 0
Engineering Persvanel 9.790 2.37_5 11.860 Inservice Inspection Maintenance Personnel 3.350 54,J_40 31.735 Operations Personnel 0.095 0
0 Health Physics Personnel 0.335 0.010 2.925 Supervisory Personnel 0
0.260 0
Engineering Personnel 10.900 1.820 P7.395 Special Maintenance Maintenance Personnel 86.110 119.935 7.885 Operations Personnel 25.400 0
0 Health Physics Personnel 6.545 0.455 4.800 Supervisory Personnel 4.185 0
0 Engineering Personnel 25.295 11.740 49.450 Waste Processing Maintenance Personnel 2.770 4.700 9.905 Operations Personnel 17.670 0_
0 Health Physics Personnel 1.475 0.015 0.110 Supervisory Personnel 0.450 0
0 Engineering Personnel 0.71 0 0.040 0.120 Refueling Maintenance Personnel 60.275 109.650 13.040 Operations Personnel 50.945 0
0 Health Physics Personnel 7.565 0.995 25.530 Superv'sory Personnel 0.245 0
0 Engineering Personnel 11.385 6.270 10.370 Totals Maintenance Personnel 22n 600 450.235 89.120 Operations Personnel 179 615 0.565 0
Health Physics Personnel 47 n1; 2.610 43.g40 Supervisory Personnel n.1Rn 0.440 0.230 Engineering Personnel 92 RR; 25.130 162.030 Grand Totals - Man-Rems 557 015 479.200 295.32 2305 109
\\
APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
Oyster Creek Total: 1546.36 Total Man-Rem Station Utility Contract Wor' and Job Function Employees Employees Emoloyees Reactor Operations & Surveillance Maintenance Personnel 0
0 0
Operations Personnel 47.410 0
1.525 Health Physics Personnel 2.500 0
0 Supervisory Personnel 3.355 0.4Z5 0.615 Engineering Personnel 5.525 2.705 8.355 Routine Maintenance Maintenance Personnel 109.105 0
0 Operations Personnel G0 4.760 0
Health Physics Personnel 12d0_0 0_
0 Supervisory Personnel 5.680 1.370 0
Engineering Personnel 5.083 2.500 0
Inservice Inspection Maintenance Personnel 0
0 19.0i5 Operations Personnel 1.550 0
0 Health Physics Personnel 0.800 0
2.335 Supervisory Personnel 1.300 0.31 0 1.620 Engineering Personnel 4.515 0.385 37.925 Special Maintenance Maintenance Personnel 57.535 62.460 748.075 Operations Personnel 22.95D 0
1.210 Health Physics Personnel TD300 0
80.590 Supervisory Personnel 2.935 0.710 36.430 Engineering Personnel 1G5 9.660 37.965 Waste Processing Maintenance Personnel 43.450 0
2.730 Operations Personnel 77.825 0
0 Health Physics Personnel 9.000 0
2.075 Supervisory Personnel PJ65 0
0 Engineering Personnel 6.555 0
0.135 Refueling Maintenance Personnel 4.900 0
15.450 Operations Personnel 2.370 0
0 Health Physics Personnel 0.500 0
0.575 Supervisory Personnel 0.285 0
3.110 Engi.ieering Personnel 2.335 0.880 4.175 Totals Maintenance Personnel 214.99 62.460 785.33 Operations Personnel 153.655 4.760 2.735 Health Physics Personnel 35.800 0
85.575 Supervisory Perscnnel 15.820 2.865_
41.775 Engineering Personnel 35.910 16.130 88_555 Grand Totals - Man-Rems 456.175 86.215 1003.970 4 1 2305 110 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTIflG OF ltAN-REM AND NUMBER OF PERSONNEL BY WORK AND JOB FUNCTION Plant:
Palisades Total: 89.845 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Eng,1 oyees Reactor Operations & Surveillance Maintenance Personnel 0.785 0
0 Operations Personnel S 039 0
0 Health Physics Personnel 3776~
0 0
Supervisory Personnel 0.776 0731~6 0
Engineering Personnel 1.929 0
d Routine Maintenance Maintenance Personnel
- 24 842 E6Bl 0
Operations Personnel 07469 0
0 Health Physics Personnel C927 0
0 Supervisory Personnel 2.249 0
0 Engineering Personnel
[f60 0
0 Inservice Inspection Maintenance Personnel 0
0 0_
Operations Personnel 0.052 0
0 Health Physics Personnel 07206 0
0 Supervisory Personnel 0.191 0
d Engineering Personnel 0.341 0
0 Special Maintenance flaintenance Personnel 9.672 0
14 m 2_ __
Operations Personnel 0.094 Q
__ __Q 3
Health Physics Personnel 0
Q Q_
Supervisory Personnel 0.166 0
0 i
Engineering Personnel 4.500 0
0,_9_Q7 3
Waste Processing Maintenance Personnel 0.969 0
0 Operations Personnel 2.057 0
0 Health Physics Personnel 0_.596 0
0 Supervisory Personnel 0.294 0
0 Engineering Personnel 0.010 0
0 Refueling Maintenance Personnel 0.235 0.320 0
Operations Personnel 0.175 0
0 Health Physics Personnel 0.032 0
0 Supervisor / Personnel 0.002 0
0 Engineering Personnel 4.752 0
5.615 Totals i
Maintenance Personnel 36.003 4.001 14.532 Operations Personnel 7.876 0
0 Health Physics Personnel 4.936 0
0 Supervisory Personnel 3.677 0
0 Engineering Personnel 11.982 0.316 6.522 Grand Totals-Man-Rems 64.474 4.317 21.054 2305 lll APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Peach Bottom 2, 3 Total: 1873.74 Tot M an-Rem Station UtiTity contract Work and Job Function Employees Employees Erployees Reactor Operations & Surveillance Maintenance Personnel 0.15 38.22 20.80 Operations Personnel 26JE_
LQ.92 120 Health Physics Personnel 9.49 1.11 55.75 Supervisory Personnel 0.39 023 0.33 Engineering Personnel SA LQ0 16.73 Routine Maintenance Maintenance Personnel L3L
_R4J8 745.36 Operations Personriel 1 04 ldB 9.8 2
Hedith Physics Personnel 1R 0
__10Eli Supervisory Personnel 0
0 0.17 Engineering Persunnel 0.29 4.83 2.34 Inservice Inspection Maintenance Personnel 0
45.71 37.15 Operations Personnel 0
6.50_
2.70 Health Physics Personnel 0
0 0.36 Supervisory Personnel 0
0 3.05 Engineering Personnel 0
L21 Ou25 Special Maintenance Maintenance Personnel 0
0.21 232.87 Operations Personnel 0
0 0
Health Physics Personnel 0
0 1.81 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 8.77 Waste Processing Maintenance Personnel 0
0.85 0.80 Operations Personnel 6.65 0__
0 Health Physics Personnel 0
5 9.00 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
1.87 1.21 Operations Personnel 0.66 0
0 Health Physics Personnel 0
0 7.00 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Totals Maintenance Persnnnel 3.48 511.44 1038.19 Opetations Personnel 35.10 27.00 14.30 Health Physics Personnel 10.58 1.11 180.13 Supervisory Personnel 0.39 0.23 3.55 Engineering Personnel 6.11 14.04 2R 09 Grand Totals - Man-Rems 55d6 SE2.82 1264.26 2305 112 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF t1AN-REM AND NUMBER OF PERSONNEL BY WORK AND JOB TUNCTION Plant:
Pilgrim 1 Total: 2566.978 Total Man-Rem Station Utility Contract Work and Job Function EmE.loyees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 24.///
0 0
Operations Personnel
_ 42.074 0
_Q Health Physics Personnel 8.604 0
6.218 Supervisory Personnel 29.483 0
0 Engineering Personnel 6d23 0
1.638 Routine Maintenance Maintenance Personnel 49.553 0
127.15_4 Operations Personnel 15.086 0
0 Health Physics Personnel 12.906 1.531 10.714 Supervisory Personnel 28.133 0
0 Engineering Personnel 4.8 13.355 0
Inservice Inspection Maintenance Personnel 0
0 155.577 Operations Personnel 0
0 0
Health Physics Personnel 0
0 7.238 Supervisory Personnel 0
5.970 0
Engineering Personnel 0
4.452
__l6 286 Special Maintenance flaintenance Personnel 69.375 77 803 10Bal37_ _
Operations Personnel 36.461 0
0 Health Physics Personnel 39.076 1.750 78.61R Supervisory Personnel 35.166 0
0 Engineering Personnel 13.962 44.610 81.103 Waste Processing Maintenance Personnel 59.464 0
149.753 Operations Personnel 75.202 5.364 0
Health Physics Personnel 8.604 0
11.476 Supervisory Personnel 0
0 o
Engineering Personnel 10.733 0
0 Refueling Maintenance Personnel 24.777 n
pn 719 Operations Personnel
- 18. ci19 0
n Health Physics Personnel 9.124 n
12 a7A Supervisory Personnel 7.011 n
n Engineering Personnel 4.6g2 0
9 Totals Maintenance Personnel 227.946 77.803 1541.939 Operations Personnel 187.362 5.364 0
Health Physics. Personnel 78.314 3.281 136.760 Supervisory Personnel 99.815 5.970 0
Engineering Personnel 40.88 62.417 99.127 Grand Totals-Man Rems 634.317 154.835 1777.826 2305 i13 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM AND NUMBER OF PERSONNEL BY WORK AND JOB FUNCTION Plant:
Point Beach 1, 2 i Total: 47QtJ2 7
Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees _
Reactor Operations & Surveillance 0*
Maintenance Personnel 0.215 0
Operations Personnel 38.336 0
Health Physics Personnel 28.606 0
Supervisory Personnel Od99 0
Engineering Personnel 1.306 0
Routine Maintenance 5.856*
Maintenance Personnel 6.312 0
Operations Personnel 1.763 0
Health Physics Personnel 1.706 0
Supervisory Personnel 0
0 Engineering Personnel 0
0 Inservice Inspection 7.296*
Maintenance Personnel 26.261 0
Operations Personnel l_4.075 0
Health Physics Personnel 0.572 0
Supervisory Personnel 0.757 0
Engineering Personnel 0.736 0
Special Maintenance 219 227*
liaintenance Personnel 34.298 0
Operations Personnel 2.873 0
Health Physics Personnel 0.182 0
Supervisory Personnel 0
0 I
Engineering Personnel 0.166 0
j Was.t Processing Maintenance Personnel 0
0 Operations Personnel 9.263 0
Health Physics Personnel 1.645 0
Supervisory Personnel 0
0 Engineering Personnel 0
0 Refueling Maintenance Personnel 0
n Operations Personnel 12.04 c; n
Health Physics Personnel 0.669 0
Supervisory Personnel 0
0 Engineering Personnel 1.348 0
Totals Maintenance Personnel 122.086 0
Operations Personnel' 18.355 0
Health Physics Personnel 33.380 0
Supervisory Personnel 0.956 0
Engineering Personnel 3.556 0
Grand Totals-Man-Rems 238.333 0
232.379*
- Br.eakdown by Job Funct' ton not provided by licensee.
2305 II4 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM AND NUMBER OF PERSONNEL BY WORK AND JOB FUNCTION Plant: Prairie Island 1. 2
_ Total : 277,581 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees __ Employees Reactor Operations & Surveillance Maintenance Personnel 2.UJ9 U
0 Operations Personnel 32.875 5333 0
Health Physics Personnel 16.980 0
0.140 Supervisory Personnel 4.812 0.238 0
Engineering Personnel 3.418 1.655 0 651 Routine Maintenance Maintenance Personnel 4.850 0.737 0
Operations Personnel 0206 0.235 0
Health Physics Personnel 0.191 0
0 Supervisory Personnel 0.022 0
0 Engineering Personnel 0.565 0
0 In:>rvice Inspection Maintenance Personnel 0.432 7.445 0
Operations Personnel 0_
0 0
Health Physics Personnel 0.063 0
2.696 Supervisory Personnel 0
0.015 0.446 Engineering Personnel 0.611 0
30.389 Special Maintenance
~
Maintenance Personnel 43.919 24.322 10.162 Operations Personnel 3.514 9.094 0
Health Physics Personnel 1.372 0
3.652 Supervisory Personnel 0.9_81 0.6_69 0.058 6
Engineering Personnel 1.896 0.297 4.091 Waste Processing Maintenance Personnel 2.359 0
0 Operations Personnel 10.890 0
0 Health Physics Personnel 2.700 0
0 Supervisory Personnel 0.413 0
0 Engineering Personnel 0.367 0
0 Refueling Maintenance Personnel 12.424 13.266 0
Operations Personnel 3.021 3.13 0
Health Physics Personnel 0.242 0_
3.536 Supervisory Personnel 2.438 0.706 0
Engineering Personnel 0.952 0.363 0
[
Totals i
Maintenance Personnel 66.023 45.77 10.162 Operations Personnel 50.509 18.092 0
Health Physics Personnel 21.548 0
10.024 Supervisory Personnel 8.666 1.628~
35.131 0.504 Engineering Personnel 7.809 1.715 Grand Totals-Man-Rems 154.555 67.205 55.821 2305 115 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Quad Cities 1 & 2 i Total: 1014.3 Total Man-Rem Station UtiTity Cont act Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 2.0 0
0 Operations Personnel SL9 0
0 Health Physics Personnel 18.9 0
0 Supervisory Personnel 12.6 0
0 Engineering Personnel 21.5 0
0 a
Routine Maintenance
- wg Maintenance Personnel 229.0 0
Operations Personnel 9.1 0
Health Physics Personnel 11.3 0
Supervisory Personnel 45.7 0
Engineering Personnel 0
0 Inservice Inspection Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Special Maintenance Maintenance Personnel 0
20.4 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Waste Processing Maintenance Personnel 1.4 0
0 Operations Personnel 154.1 0
0 Health Physics Personnel 32.8 0
0 Supervisory Personnel 16.2 0
0 J ngineering Personnel 0
0 0
Refueling Maintenance Personnel 0
0 0
Operations Personnel 20.5 0
0 Health Physics Personnel 0
0 0
L pervisory Personnel 1.4 0
0 Engineering Personnel 0
0 0
Totals Maintenance Personnel 232.4 20.4 Operations Personnel 234.6 0
Health Physics Personnel 63.0 0
Supervisory Personnel 75.9 0
Engineering Personnel 21.5 0
Grand Totals - Man-Rems 627.4 20.4 366.5 2305 116
- Includes Inservice Inspection Exposures.
aBreakdown by Job Function not provided by licensee.
APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant: Rancho Seco Total: 406.35 Total Man-Rem Station Utili ty Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 5.34 0.45 11 51 Operations Personnel 8.13 0.13 0
Health Physics Personnel 7.12 0
6.95 Supervisory Personnel 0.61 0
1.07 Engineering Personnel 1 96 0
0.80 Routine Maintenance
- Maintenance Personnel 40.47 2.17 86.71 Operations Personnel 6.42 0
0 Health Physics Personnel 9.27 0
6.69 Supervisory Personnel 0.47 0
2.14 Engineering Personnel 2.46 0
1.87 Inservice Inspection Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Special Maintenance Maintenance Personnel 28.25 5.75 74.09 Operations Personnel 0.73 0
0 Health Physics Personnel 5.00 0
8.37 Supervisory Personnel 0.67 0
0.80 Engineering Personnel 1.96 0
11.21 baste Processing Maintenance Personnel 5.41 0.08 22.17 Operations Personnel 3.27 0
0 Health Physics Personnel 3.21 0
0.80 Supervisory Personnel 0.41 0
0 Engineering Personnel 0.54 0
0 Refueling Maintenance Personnel 2.10 0.48 2.94 Operations Personnel
- 4. 47'-
0.19 0
Health Physics Personnel 0.21 0
0.03 Supervisory Personnel 0
0 0
Engineering Personnel
- 0. 4t, 0
0.03 Totals Maintenance Personnel 81.57 8.93 217.42 Operations Personnel 23.02 0.32 0
Health Physics Personnel 24.81 0
22 R4 Supervisory Personnel 2.16 0
4_01 Engineering Perscnnel 7.36 0
11 ol Grand Totals - Man-Rems 138.92 9.25 25R.1R
- Includes Inservice Inspection Exposures.
2305 117 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
H. B. Robinson 2 t Total: 455.491 Total Man-Rem Station Utility ContWct Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 1.057 0
1.266 Operations Personnel 33.209 0
0 Health Physics Personnel 10.311 1.063 0.014 Supervisory Personnel 0.590 0.352 0
Engineering Personnel 3.51 6 0.603 0
Routine Maintenance Maintenance Personnel 32.999 0
22.793 Operations Personnel 0
0 0
Health Physics Personnel 2.864 1.006 0
Supervisory Personnel 0
0 0
Engineering Personnel 1.31 8 0.603 0
Inservice Inspection Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0.033 Engineering Personnel 0
0 0
Special Maintenance Maintenance Personnel 58.522*
13.981 154.161*
Operations Personnel 5.629 0
0 Health Physics Personnel 11.457*
4.364*
0 Supervisory Personnel 0
0 0
Engineering Personnel 5.604 4.223 0
Waste Processing Maintenance Personnel 15.600 0.603*
44.725*
Operations Personnel 17.449 0
0 Healon Physics Personnel 4.010 1.006 0
Supervisory Personnel 0
0 0
Engineering Personnel 0.550 0
0 Refueling Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Totals Maintenance Personnel 108.178
- 14.584
- 222.945
- Operations Personnel 56.287 0
0 Health Physics Personnel 28.642
- 7.439
- 0.014 Supervisory Personnel 0.590 0.362 0.033 Engineering Personnel 10.988 5.429 0
Grand Totals - Man-Rems 204.685 27.814 222.992
- Includes exposures reported under "deconning" by licensee.
2305 Ii8 APPENDIX C STANDARD F0hMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
St. Lucie Total: 130.57 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 0
0 0
Operations Personnel 7.90 0
0 Health Physics Personnel 4.51 0
0 Supervisory Personnel 0.15 0
0.21 Engineering Personnel 0.26 0
0 Routine Maintenance Maintenance Personnel 43.69 0
12.53 Operations Personnel 0.33 0
0 Health Physics Personnel 5.57 0.22 0.13 Supervisory Personnel 0.15 0.11 0.79 Engineering Personnel 0
0 0.14 Inservice Inspection
- Maintenance Personnel 3.35 0
5.94 Operations Personnel 15.63 0
0 Health Physics Personnel 6.47 0
0 Supervisory Personnel 0.71 0.11 0.41 Engineering Personnel 1.24 0
1.65 Special Maintenance flaintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Waste Processing Maintenance Personnel 10.55 0
0 Operations Personnel 2.91 0
0 Health Physics Personnel 4.91 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Totals Maintenance Personnel 57.59 0
18.47 Operations Personnel 26.77 0
0 Health Physics Personnel 21.46 0.22 0.13 Supervisory Personnel 1.01 0.22 1 41 Engineering Personnel 1.50 0
1.79 Grand Totals - Man-Rems inR ll 0.44 u___21.80
- Includes Special Maintenance Exposures.
2305 119 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM AND NUMBER OF PERSONNEL BY WORK AND JOB FUNCTION Plant:
San Onofre Tog 1: 867.71 Total Man-Rem Station Utility Contract Work and Job Function Ern loyees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 3.580 0.530 10.980 Operations Personnel 15.360 0_
0 Health Physics Personnel 8.100 1.080 0
Supervisory Personnel 1.350 6~960 2.520 Engineering Personnel 10.6T6 5.840_
17.920_
Routine Maintenance Maintenance Personnel 51.870 171.460 293.290 Operations Personnel 3.140 0
0 Health Physics Personnel 7.fl0 1.770 0
Supervisory Personnel 3.590 11.420 18.840 Engineering Personnel 6.200 7.940 32.420 Inservice Inspection Maintenance Personnel 0
8c820 4280 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
_QJ00 0 _ _ _
Engineering Personnel 0
0 0 3E0__
Special Maintenance flaintenance Personnel 13.710 39.540 3EJER_
Operations Personnel 3.890 Q
_Q 9
Health Physics Personnel 3.550 OJ80 0
m Supervisory Personnel 1.210 3.9 10 0
i Engineering Personnel 8.000 1.660 26.700 Waste Processing Maintenance Personnel 6.300 0.330 2.070 Operations Personnel 1.460 0
0 Health Physics Persornel 0.730 0
0 Supervisory Personnel 0
0 1.440 Engineering Personnel 0
0 0.130 Refueling Maintenance Personnel 0
0 10.570 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel
_0 0
0 Engineering Personnel 0
0 2.120 l
Totals Maintenance Personnel 75.46 220.68 358.44 Operations Personnel 23.85 0
0 Health Physics Personnel 19.59 _.
3.53 0
Supervisory Personnel 6.15 16.81 22.8 Engineering Personnel 24.71 15.44 80.25 Grand Totals-Man-Rems 149.76 256.46 461.49 2305 120 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION i
Plant:
Surry 1, 2 Total: 2417.323 Total Man-Rem Station Utility l
Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance 315.441
- 6.233
- 43.097
- Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Routine Maintenance 296.440
- 44.732
- 53.226
- Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Inservice Inspection Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Special Maintenance 109.663
- 95.978
- 1204.776
- Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Waste Processing 62.436
- 0 19.144
- Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Refueling 31.374
- 9.544
- 125.239
- Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Totals Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel
~
Engineering Personnel Grand Totals - Man-Rems 815.354 156.487 1445.482
- Breakdown by job function not provided by licensee.
2305 121 APPENDIX C STANDARD FORMAT FOR ANNUAL. REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
Three Mile Island 1 Total: 239.742 Total Man-Pei Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance P.ntenance Personnel 0.559 0.015 0.030 Operations Personnel 6.234 0
0 Health Physics Personnel 0.876 0.003 0
Supervisory Personnel
- 2.055 0.020 0.112 Engineering Personnel 0.200 0.074 0.066 Routine Maintenance Maintenance Personnel 15.751 0.928 0.13R Operations Personnel 2.137 0.090 0
Health Physics Personnel OJ98 0.030 0
Supervisory Personnel
- 1.293 OJ05 0.035 Engineering Personnel 0.073 0.D88 0.043 Inservice Inspection Maintenance Personnel 0.345 0.023 11.936 Operations Personnel 2.090 0
0 Health Physics Personnel 0.292 0.002 0.014 Supervisory Personnel
- 0.281 0.103 0.635 Engineering Personnel 0.293 0.227 0.056 Special Maintenance Maintenance Personnel 21.122 2.376 60.735 Operations Personnel 4.638 0.020 0
Health Physics Personnel 3.266 0.001 0.605 Supervisory Personnel
- 5.430 0.107 3.874 Engineering Personnel 0.287 0.814 1.019 Waste Processing Maintenance Personnel 16.269 1.869 3.91 9 Operations Personnel 3.995 0
0 Health Physics Personnel 0.308 0.020 0
Supervisory Personnel
- 3.272 0.133 0.203 Engineering Personnel 0.097 0.079 0.050 Refueling Maintenance Personnel 21.282 6.220 1.170 Operations Personnel 16.321 0
0 Health Physics Personnel 0.772 0
0 Supervisory Personnel
- 9.975 0.266 0.037 Engineering Personnel 0 612 0.202 0.607 Totals Maintenance Personnel 7E.328 11.431 78.128 Operations Personnel 3!.415 0.110 0
Health Physics Personnel b.912 0.056 0.619 Supervisory Personnel *
?L305 0.634 4.916 Engineering Personnel 1.562 1.484 1.841 Grand Totals - Man-Rems 140.523 13.715 85.504
- Includes exposures reported for " Administrative Personnel" by licensee.
m oa c '22 g:
APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM BY WORK AND JOB FUNCTION Plant:
Trojan Total: 151.318 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 0.522 0.141 0.060 Operations Personnel 8.588 0 -
0.022 Health Physics Personnel 13.114 0
0.020 Supervisory Personnel 0.962 0.010 0.079 Engineering Personnel 0.291 0.081 2.628 Routine Maintenance
- Maintenance Personnel 1.355 9.614 15.355 l
Operations Personnel 0.015 0.010 0
Health Physics Personnel 0
0.025 5.251 Supervisory Personnel 0.008 0.420 0.292 Engineering Personnel 0.143 0.611 0.495 Inservice Inspection Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Special Maintenance Maintenance Personnel 3 002 6.458 62.544 Operations Personnel 0.070 0.008 0
Health Physics Personnel 0.597 0
0.102 Supervisory Personnel 0.229 0.070 2.861 Engineering Personnel 0.488 0.213 0.233 Waste Processing Maintenance Personnel 0
0 0.021 Operations Personnel 0
0 0
Health Physics Personnel 0.096 0
0.109 Supervisory Personnel 0
0 1.071 Engineering Personnel 0.024 0
0.010 Refueling Maintenance Personnel 0
0 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Totals Maintenance Personnel 17.879 16.213 77.980 Operations Personnel 8.673 0.018 0.022 Health Physics Personnel 13.807 0.025 5.482 Supervisory Personnel 1.199 0.500 4.301 Engineering Personnel 0.946 0 g05 3.366 Grand Totals - Man-Rems 47.504 17.661 91.151
- Includes Inservice Inspection Exposures 2305 123 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM AND NUMBER OF PERSONNEL BY WORK AND JOB FUNCTION Plant:
Turkey Point 3. 4 Total: 1455.79 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 3.58 22.44 426 Operations Personnel 55.96 0
0 Health Physics Personnel 2.73 0
25 d8 Supervisory Personnel 0
0_
4.78 Engineering Personnel 12.38 Q
0 Routine Maintenance Maintenance Personnel
- 398.14 156.64 hL30 Operations Personnel 8.56 0
0 Health Physics Personnel 2.44 0
0 Supervisory Personnel 5.42 0
0 86 Engineering Personnel 3.32 0_
0 Inservice Inspection Maintenance Personnel 0
0 601.78 Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel
_ _0 0
8m32__
Engineering Personnel 24.48 0
_0 Special Maintenance fiaintenance Personnel 0.24 0 _ _.
29 02 2
Operations Personnel 0
0
_q__
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 3.12 0
0 Waste Processing Maintenance Personnel 0
0 0
Operations Personnel 0.42 0
0 Health Physics Personnel 1.64 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 11.76 0
n Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 n
Engineering Personnel 8J2 0
0 Totals Maintenance Personnel R3.72 179 08 690.36 Operations Personnel 64.94 0
0 Health Physics Personnel 6.81 0
25.48 Supervisory Personnel 5.42 0
17.96 Engineering Personnel 52.02 0.
O Grand Totals-Man-Rems _
542.91 179.08 733.8 2305 124 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING OF MAN-REM AND NUMBER OF PERSONNEL BY WORK AND JOB FUNCTION Plant:
Vermont Yankee Total: 256.181 Total Man-Rem Station i
Utility Contract Work and Job Function Employees Employees Eg loyees Reactor Operations & Surveillance Maintenance Personnel 14.391 0.725 5.069 Operations Personnel 29.925 0
0.334 Health Physics Personnel 11.031 0
870s Supervisory Personnel 0.297 0
0 Engineering Personnel 8.262 2727 1.069 Routine Maintenance Maintenance Personnel
_ _ 24.272 62.117 65J33 Operations Personnel 2.793 0
ORO Health Physics Personnel 0.235 0
2.093 Supervisory Personnel 0
0 0
Engineering Personnel 0.225 Od54 0.166 Inservice Inspection Maintenance Personnel 0JH2 1,313 2.397 Operations Personnel 0.020-0 0
Health Physics Personnel 0J05 0
0.202 Supervisory Personnel 0
0 0
Engineering Personnel 0
0.376 0.405 Special Maintenance Maintenance Personnel 0.166 0.452 1.055 Operations Personnel Q.218 0
0_
Health Physics Personnel 0.162 0
0.121 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0.024 Waste Processing Maintenance Personnel 0.105 0.130 0
Operations Personnel 2.050 0
0 Health Physics Personnel 0
0 0.125 Supervisory Personnel 0.004 0
0 Engineering Personnel 0
0 0
Refueling Maintenance Personnel 1.411 3.061 0.82/
Operations Personnel 0.569 0
0.025 Health Physics Personnel 0.143 0
1.171 Supervisory Personnel 0
0 0
Engineering Personnel 0.228 0.049 0.040 Totals Maintenance Personnel 40.527 67.798 14.361 Operations Personnel 35.575 0
0.379 Health Physics Personnel 11.576 0
12.419 Supervisory Personnel 0.301 0
0 Engineering Personnel 8.715 2.806 1./U4 Grand Totals-Man-Rems 96.694 70.604 88.883 2305 125 APPENDIX C STANDARD FORMAT FOR ANNUAL RE>ORTING OF t1AN-REM AND NUMBER OF PERSONNEL BY W(RK AND JOB FUNCTION Plant: Yankee Rowe To tal_: 314.914 Total Man-Rem Stulon Utility Contract Work and Job Function Employees Employees Emp_loyees_
Reactor Operations & Surveillance Maintenance Personnel 2J06
_ 0.489 _
0.21T Operations Personnel 9.139 0
0 Health Physics Personnel 7.581 Od44 2J3_2 Supervisory Personnel 0.19_5 0_._09_0 0 318 _
Engineering Personnel 0.749 0.459 0.038 Routine Maintenance Maintenance Personnel 7.900 T3361 5.425 Operations Personnel 0.816 0
0 Health Physics Personnel 1.196 0
0.4_07 Supervisory Personnel 0.057 0.255 0.983 Engineering Personnel 0.007 0.303 0.010 Inservice Inspection Maintenance Personnel 1.451 13.774 9.128 Operations Personnel 3.763 0
0 Health Physics Personnel 03T8 0.020 0.300 Supervisory Personnel 4.102 1.669 0.882 Engineering Personnel 2.985 1.963 2.31 0 Special Maintenance flaintenance Personnel 16.098 24.688 77.120 ~~~
Operations Personnel 0.627 0
0_
Health Physics Personnel 3.227 0
8.656
_a Supervisory Personnel 1.183 0.357 17.7_50 i
Engineering Personnel 0.129 2.475 0.122 i
Waste Processing Maintenance Personnel 0.237 0.315 0.109 Operations Personnel 1.565 0
0 -
Health Physics Personnel 0.195 0.058 4.095 Supervisory Personnel 0
0 0.805 Engineering Personnel 0
0 0 lioF-Refueling Maintenance Personnel 6.612 14.197 7_ 695 Operations Personnel 10_.134 0
0 Health Physics Personnel 0.912 0.l_07_
14,_931 Supervisory Personnel 0.716 0.825 0.42_0____
Engineering Personnel 0.264 0.237 0.043 Totals Maintenance Personnel 34.604 66.844 99.774 Operations Personnel 26.044 0
0 Health Physics Personnel 13.629 0.629 307f/
Supervisory Personnel 6.253 3.lf6 21.158 Engineering Personnel 4.134 5.437 2.525 Grand Totals-Man-Rems 84.664 76.106 154.184 2305
!26 APPENDIX C STANDARD FORMAT FOR ANNUAL REPORTING 0F MAN-REM BY WORK AND JOB FUNCTION Plant:
Zion 1, 2 Total: 978.4 Total Man-Rem Station Utility Contract Work and Job Function Employees Employees Employees Reactor Operations & Surveillance Maintenance Personnel 1.4 0
0 Operations Personnel 4.2 0
0 Health Physics Personnel 4.0 0
0 Supervisory Personnel 3.1 0
0 Engineering Personnel 29.5 0
0 Routine Maintenance
- Maintenance Personnel 176.6 0
547 Operations Personnel 78.6 0
Health Physics Personnel 33.2 0
Supervisory Personnel 45.7 0
Engineering Personnel 0
0 Inservice Inspection Maintenance Personnel Operations Personnel Health Physics Personnel Supervisory Personnel Engineering Personnel Special Maintenance Maintenance Personnel 0
10.9 0
Operations Personnel 0
0 0
Health Physics Personnel 0
0 0
Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Waste Processing Maintenance Personnel 0
0 0
Operations Personnel 14.0 0
0 Health Physics Personnel 12.3 0
0 Supervisory Personnel 0
0 0
Engineering Personnel 0
0 0
Refueling Maintenance Personnel 0
0 0
Operations Personnel 12.2 0
0 Health Physics Personnel 0
0 0
Supervisory Personnel 5.7 0
0 Engineering Personnel 0
0 0
Totals Maintenance Personnel 178.0 10.9 547 Operations Personnel 109.0 0
0 Health Physics Personnel 49.5 0
n Supervisory Personnel 54.5 0
0 Engineering Personnel 20_R n
n Grand Totals - Man-Rems 420.5 10.9 547
- Includes Inservice Inspection exposures.
2305 127
U.S. NUCLE AR REGUL ATORY COMMISSION BIBLIOGRAPHIC DATA SHEET NUREG-0482
- 4. TITLE AND SUBTITLE (Add Volume No.,4/ apprqorsare)
- 2. (Leave blank /
OCCUPATIONAL RADIATION EXPOSURE AT LIGHT WATER COOLED POWER REACTORS - 1977
- 3. RECIPIEN T'S ACCESSION NO.
- 7. AUTHOR (S) 5 OAT E RE PORT COMPLE TE D
^"
Linda Johnson Peck April 1979
- 9. PERFORMING ORGANIZATION NAME AND MAILING ADDRESS (loctude lep Codel DATE REPORT ISSUED I^"
U.S. Nuclear Regulatory Commission Office of Management & Program Analysis Washington. D.C.
20555 6d "*"
- 8. (L eave blan k )
- 12. SPONSORING ORGANIZ ATION N AME AND M AILING ADDRESS (include lip Cudel
- 10. PROJECT / TASK / WORK UNIT NO U.S. Nuclear Regulatory Commission Office of Management & Program Analysis
- 11. CONT R ACT NO.
Washington, D.C.
20555
- 13. TYPE OF REPORT PE 9100 COVE RE D (/nclussve datesJ Annual Report Calendar Year 1977
- 15. SUPPLEMENTARY NOTES
- 14. (Leave 6/ank)
- 16. ABSTR ACT (200 words or less)
This report presents an updated compilation of occupational radiation exposures at commercial light water cooled nuclear power reactors (LWRs) for the years 1969 through 1977. Data from 57 U.S. nuclear power plants that completed at least one full year of commercial operation as of January 1,1978 are included.
The number of personnel monitored at LWRs increased approximately 10% in 1977, and the average collective dose to personnel (man-rems per reactor-year) increased 14% over the 1976 average. The average number of personnel receiving measurable exposure per reactor increased 11%, and the average exposure per individual in 1977 was 0.8 rem per person.
2305 128
- 17. KE Y WORDS AND DOCUME NT AN A LYSIS 17a. DESCRIPTORS Not Applicable.
17b. IDEN TIFIE RS/OPEN EN DE D TERMS
- 18. AV AILABILITY STATEMEN T
- 19. SECURI TY CLASS (T/,,s reporrl
- 21. NO. OF P AGES Un1imited*
- 20. SECURITY CLASS (Th,s pap /
- 22. PRICE S
N RC f ORM 3M 17 7 7)
UNITE D ST ATES f
]
NUCLE AR REGULATORY COMMISSION WASHING TON. O. C. 20$56 rogr aGa amo r g e s raio u5 MuCLgam ngGuLaTORY OF F ICI A L BUSI N E SS comuission PE N AL.T Y F O R PRtV AT E USL, $300 L
J 120555031837 2 COC3NRAN US NRC SEC Y PUBLIC DOCUMENT ROOM BRANCH CHIEF HST LOBBY WASHINGTON DC 20555 2305 129