e~ s e r e SourH CAnoLINA ELECTRIC a gas COMPANY woss ore,cs eon ras CotumalA Souts,CApouwA aerie E, H. Ca tws, J n.

v <. 4.........

. c.. c.,m.

February 13, 1979 c....,.c..,,....

Mr. James P. O'Reilly, Director United States Nuclear Regulatory Commission Region II, Suite 1217 230 Peachtree Street, N. W.

Atlanta, Georgia 30303

Subject:

Virgil C. Sunner Nucicar Station Inspection & Enforcement Bulletin 78-04 Docket No. 50-395 NE File 2.8950

Dear Mr. O'Reilly:

Our correspondence to you dated April 18, 1978, on action required in IEB 78-04 indicated that specific actions needed to satisfy the concerns were still under study.

Since that time our investigation has been com-pleted and the corrective action we are taking is outlined in our response to FSAR Ouestion 031.57, a copy of which is attached.

This action satisfies the concerns of this IEB and is considered our final report.

Ifyouhaveanyfurtherquestiokconerningouractionsinthiscase, please do not hesitate to contact u.

x Ver t

yours,

/

w; C s, Jr.

j SMC:EHCJr:msd CC: Messrs.

V. C.

Summer E. H. Crews, Jr.

D. A. Nauman M.

B. Whitaker, Jr.

H. T. Babb T. B. Ccnner NPCF/Dixon File

]YOO$Y OFFICIAL COPY 7903146 50'/

031.57 In a letter to the NRC Staff dated August 17, 1977 Westinghouse described a deficiency in their seismic and environmental qualification tests of stem mounted limit switches used on safety related motor operated valves and air operated valves.

This letter, number NS-CE-1489, REF: NS-CE-692 (7/10/75) was sent from Mr. C. Eiche1dinger to Mr. John F. Stoltz of the NRC Staff.

We request that the applicant review the Virgil C. Summer design for all safety related motor operated and air operated valves and verify that all deficiencies identified in the Westinghouse letter have been rectified if any existed. Also identify all deficiencies which still exist. Amend the FSAR to include the results of the review and a description of all changes to correct the deficiencies.

RESPONSE

Ste mounted '.imit switches within the scope of I&E Bulletin 78-04 have been or are being replaceil at the manufacturer's facility or will be replaced at the plant site for the following valves:

a.

XVB-0001B-AH b.

XVB-00028-AH c.

XVG-503A-BD, XVC-503B-BD, XVG-503C-BD d.

XVG-9627A-CC, XVC-9627B-CC e.

XV' -1678A-FW, XVT-1678C-FW f.

XVT-2660-IA g.

XVT-2662A-IA, XVT-2662B-IA h.

XVM-2801A-MS, XVM-2801B-MS, XVM-2801C-MS 1.

XVT-2843A-MS, XVT-2843B-MS, XVT-2843C-MS j.

XVT-2869A-MS, XVT-2869B-MS, XVT-2869C-MS k.

XVT-2877A-MS, XVT-2877B-MS 1.

XVA-9311A-SS, XVA-9311B-SS

m.

XVA-9312A-SS, XVA-9312B-SS n.

XVT-6384A-VU, XVT-6384B-VU o.

XVT-6385A-VU, XVT-6385B-VU p.

LCV-459, LCV-460 q.

7126 r.

6047 s.

8149A, 8149B, 8149C t.

8701B u.

8702A v.

8871

.