ML19260D867

From kanterella
Jump to navigation Jump to search

Forwards B&W Rept, Potential Reactor Sys Voiding During Anticipated Transients, in Response to NRC .Util Review of B&W Investigation Concludes No Voiding Occurs
ML19260D867
Person / Time
Site: Davis Besse 
Issue date: 02/07/1980
From: Crouse R
TOLEDO EDISON CO.
To: Reid R
Office of Nuclear Reactor Regulation
Shared Package
ML19260D868 List:
References
588, TAC-45218, NUDOCS 8002120529
Download: ML19260D867 (1)


Text

3 TOLEDO

%mm EDISON m n:..n P Cacuss Docket No. 50-346 a;- -t License No. NPF-3 4 ' m N2 '

Serial No. 588 February 7, 1980 Director of Nuclear Reactor Regulation At tention :

Mr. Robert N. Reid, Chief Operating Reactors Branch No. 4 Division of Operating Reactors United States Nuclear Regulatory Commission Washington, D.

C.

20555

Dear Mr. Reid:

This is in response to your letter to all licensees of Babcock and Wilcox (B&W) nuclear steam supply systems, dated January 9,1980, expressing a concern on the potential for reactor coolant system voiding during transients on B&W plants.

Attached is a discussion titled " Potential Reactor System Voiding During Antici-pated Transients" dated January, 1980, which is our response on this matter re-lative to Davis-Besse Nuclear Power Station Unit 1, (DB-1).

B&W has investigated the concern, reviewed the data from the transients referenced by the NRC Of fice of Inspection and Enforcement (I&E),and prepared the attached report in response.

Our review of the investigation concludes that voiding does not occur in the reactor coolant system during anticipated transients.

Toledo Edison Company considers this matter resolved and plans no additional analyses or submittals.

Very truly yours,

l RPC:TKR: cts k

Attachment 0 9\\

t 8002120 529 THE TCLECO ECISCN CCMPANY EC;SCN PLAZA 300 VACISCN AVENUE TCtEDO, OHIO 43652 P