ML19260D862

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 70-1151/79-17 on 791127-30 & Notice of Violation
ML19260D862
Person / Time
Site: Westinghouse
Issue date: 12/12/1979
From: Kenna W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Damore M
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML19260D858 List:
References
NUDOCS 8002120520
Download: ML19260D862 (2)


Text

.

  1. pn neo

'o,,

UNITED STATES NUCLEAR REGULATORY COMMISSION n

,E REGION 11

((

101 MARIETTA ST N.W.. SUITE 3100 0,

ATLANTA, GEORGIA 303o3 DE C 121979 In Reply Refer To:

RII:GPC 70-1151/79-17 Westinghouse Electric Corporation ATTN:

M. D'Amore, Manager Columbia Plant Nuclear Fuel Division Drawer R Columbia, SC 29205 Gentlemen:

This refers to the inspection conducted by G. P. Coryell of this office on November 27-30, 1979 of activities authorized by hPC License No. SNM-1107 for the Columbia Nuclear Fuel facility, and to the discussion of our findir gs held with R. J. Wiggins at the conclusion of the inspection.

Areas examined dur!ng the inspection and our findings are discussed in the enclosed inspectica report.

Within these areas, the inspection consisted of selective examina'. ions of procedures and representative records, interviews with personnel, and ofservations by the inspector.

During Lne inspection, it was found that certain activities under your license appear to be in noncompliance with NRC requirements.

This item and references to pertinent requirements are listed in the Notice of Violation enclosed herewith as Apperdix A.

This notice is sent to you pursuant to the provisions of Sec-tion 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations. Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, a written statement or explanation in reply including:

(1) corrective steps which have been taken by you and the results achieved; (2) corrective steps which will be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.

If this report contains any information that you (or your contractor) believe to be proprietary, it is necessary that you make a written application within 20 days to this office to withhold such information frbm public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that pyoprietary information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placesLin the Public Document Room.

ggh 1

3002 20 520

DE C 121979 Westinghouse Electric Corporation.

Should you have any questions concerning this letter, we will be glad to discuss them with you.

Sincerely, w::

n. B. Kenn Chief Safeguards Branch

Enclosures:

1.

Appendix A, Notice of Violation 2.

Inspection Report No. 70-1151/79-17 f

o P