h; -

License No. 35-11132-01 NOTICE OF VIOLATION Based on the results of the NRC inspection conducted on October 17, 1979, certain activities appear to be in noncompliance with NRC regulations and the conditions of your hTC License No. 35-11132-01 as indicated below:

1.

License Condition 14.A requires that sealed sources shall be tested for leakage and/or contamination at intervals not to exceed six months.

Contrary to this requirement, a 300-microcurie strontium-90 source in use at the facility of the licensee had not been tested since January 1966.

This is an infraction.

2.

Contrary to 10 CFR 19.11(a) or (b), neither the documents required by 10 CFR 19.11(a) nor the notice required by 10 CFR 19.11(b) were posted at the time of the inspection.

This is a deficiency.

1954 163 8002120 M