Appendix A NOTICE OF VIOLATION Consumera Pswer Company Docket No. 50-330 s
Based on the results of an NRC inspection conducted on October 9-12, 1979, it appears that certain of your activities were not conducted in full com-pliance with NRC requirements as noted below. This item is an infraction.
10 CFR 50, Appendix B, Criterion V, states, in part, that, " Activities affecting quality shall be prescribed by documented instruction, proce-
- dures,
.. and shall be accomplished in accordance with these instruc-tions, procedures, Bechtel Quality Assurance Manual ASME Section III Nuclear Components Division 1, paragraph 5148, states in part, that,
. Requirements for receipt, inspection, stcrage, icaue and return to stock of welding filler materials are in WFMC-1.
Bechtel Power Corporation Procedure Specification No. WFMC-1, Revision 6, Amendment 2, paragraph 6.5.8.1, states, in part, that, "The portable warmers shall be energized within three hours of the electrode issuance from the rod room.
Contrary to the above, the inspector established the following:
On October 9, 1979, approximately 3:00 p.m. a portable oven with a.
I.D. No. 288, containing approximately 30 sticks of 3/32" diameter E7018 welding rods was left unenergized in the Unit 2 Containment Building adjacent to the Emergency Personnel Hatch.
The welding rods were cold to touch. The welding rods were issued to be used on weld No. M326-2880W, of Systems No. 10"-2HBC-110-H9 on drawing No. 619-2-9.
b.
On October 10, 1979, approximately 2:00 p.m.,
a portable oven with I.D. No. 286, containing approximately 60 sticks of 3/32" and 1/8" diameter E7018 welding rods was left unenergized in the Unit 2 Con-tainment Building at approximately elevation 611'-0" and 270 azimuth.
The welding rods 9ere cold to touch. The welding rods were issued to be used on weld No. M326-2496W, of system No. 10"-2HBC-110-H28, on drawing No. 619-2-30.
c.
The portable ovens were issued to the welders at 7:00 a.m. on the days in question according to the logs kept at the rod room.
d.
No welding has been performed at the time when the conditions were noted because no weld rod stub was in the stub can.