-.bg n,,

Ut!!TED STATES

}

sn ATOMIC EN"RGY COMM!SSION

NGY.\\

nnnonu nr enupuwcr 201 sas.

,1 -

  • < /Yl nccion i e

h #"/

970 DROAD STREET 3942 NEWARK. NEW JERSEY G7102 MAY 101972 i

i 11etropolitan Edison Company Docket No. 50-289 i

Attcution: tir. J. G. }Iiller Vice President P. O. Box 542 Reading, Pennsylvania 19603 D

D N

Mh Centlemen:

JT WbuGu@j'/t_a This refers to the inspection conducted by 11r. S. A. Folsom of this office on April 4-5, 1972 of construction activitics authorized by 3

AEC Construction Permit No. CPPR-40 and to the discussions of our findings held by fir. Folsom with !!r. E. W. Allen of your secff at the conclusion of the inspection.

The area examined duri g this inspection was the audit conducted by O

co=R Associates and General Public Utilities Corporation of the Crane IIP P =7.

ca P=== otvi ta=. s== tit 7 a

=r==ce Prosr====d record -

Within this area, the inspection consisted of selective examinations of procedures and representative records, intervicus with plant per-

"sonnel, and observations by our inspector.

i Ro items of nonconformance were identified by our inspector during this inspection.

During our observations of your audit, it was found that deficiencies in procedures and documentation were identified by your audit team; however, we understand, based on discussions with cechers of your staff at the conclusion of the inspection, that you will obtain resolution of these deficiencies by taking the necessary corrective actions. These i'

actions will be reviewed during our next inspection of your Three tiile Island Unit 1 facility.

l No reply to this letter is necescary; houever, should you have any questions concerning this '.nspection, we will be pleased to discuss them with you.

Very truly yours, Jancs P. O'ReGly

/

CO:I:SAF Director

'J N910290]6h

~

1480 232