TESN fg no%jo, UNITED STATES

+

I,h.n NUCLEAR REGULATORY COMMISSION

.g") iE WASHINGTON, D. C. 20555 k

January 22, 1980 Docket No. 50-313 Mr. William Cavanaugh, III Vice President, Generation and Construction Arkansas Power & Light Company P. O. Box 551 Little Rock, Arkansas 72203

Dear Mr. Cavanaugh:

SUBJECT:

REQUEST FOR INFORMATION ON THE EFFECTS OF CERTAIN VALVE LINE-UP PROCEDURAL CHANGES Based upon design review, we have determined that Arkansas 1, Crystal River 3, Oconee 1, 2, and 3, Rancho Seco and Three Mile Island I have two check valves in series with a closed motor operated valve (MOV) to isolate the low pressure safety injection system from the reactor coolant system. We have recently completed a study of this configuration (0conee) and its contribution to the risk of core melt.

The results show a higher value contribution to the risk of core melt from a loss of coolant accident outside of containment than previously found for Surry (WASE-1400). We are studing this matter and pursuing interim and permanent resolutions.

Tne pennanent fix, which is being addressed as part of the review of your Inservice Testing Program, requires a leak test of the check valves or an equivalent test. The proposed interim resolution seeks to place the check valves under continuous test by requiring that the plant be started up and operated with the MOV open. Before we adopt this temporary fix, we wish to be assured that this interim approach carries no unacceptable adverse safety impact.

We have, in the past, discussed the following questions with members of y:ur staff:

1.

What is the adverse safety impact of starting up the plant with the MOV in the open position?

2.

What is the adverse safety impact of operating the plant with the MOV in the open position?

In order to assess the impact of the proposed MOV position and to allow your comments to be considered prior to our resolution of this issue, kindly submit your response to the two questions above within 45 days of receipt of this letter.

lbb Si ncerely,

Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors cc:

See next pace 8002040 OY L

Arkansas Power & Light Company cc:

Mr. David C. Trimble

~ Manager, Licensing Arkansas Power & Light Company P. O. Box 551 Little Rock, Arkansas 72203 Mr. James P. O'Hanlon General Manager Arkansas Nuclear One P. O. Box 608 Russellville, Arkansas 72801 Mr. William Johnson U. S. Nuclear Regulatory Commission P. O. Box 2090 Russellville, Arkansas 72801 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 420, 7735 Old Georgetown Road Bethesda, Maryland 20014 Troy B. Conner, Jr., Esq.

Conner, Moore & Corber 1747 Pennsylvania Avenue, N.W.

Washington, D.C.

20006 Arkansas Polytechnic College Russellville, Arkansas 72801 Director, Bureau of Environmental Health Services 4815 West Markham Street Little Rock, Arkansas 72201 1864 160

.