ML19257B025

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 79-36, Computer Code Defect in Stress Analysis of Piping Elbow. No Specific Action or Response Required
ML19257B025
Person / Time
Site: Sterling
Issue date: 12/31/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Arthur J
ROCHESTER GAS & ELECTRIC CORP.
References
NUDOCS 8001150118
Download: ML19257B025 (1)


Text

,# f~,necog ge.

jo,,

UNITED STATES

,y ', ) e 3 g NUCLEAR REGULATORY COMMISSION

... t REGION I

]%['
  • s>[o,8 o

631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA 19406 Docket No. 50-485 DEC 3 1 1979 Rochester Gas & Electric Corporation ATTN: Mr. J. E. Arthur Chief Engineer 89 East Avenue Rochester, New York 14649 Gentlemen:

The enclosed IE Information Notice No. 79-36 provides information on a coinputer code defect which can result in incorrect stress values for piping elbows.

Sincerely, sY bb 23

.j Boyce H. Grier Director

Enclosures:

1.

IE Information Notice No. 79-36 2.

List of Recently Issued IE Information Notices CONTACT:

L. E. Tripp (215-337-5282) cc w/encls:

C. R. Anderson, Manager, QA Lex K. Larson, Esquire N. A. Petrick, Executive Director, SNUPPS Gerald Charnoff, Esquire 1745 065 800115011f

ENCLOSURE 1 UNITED STATES SSINS No.:

6870 NUCLEAR REGULATORY COMMISSION Accession No:

OFFICE OF INSPECTION AND ENFORCEMENT 7910250519 WASHINGTON, D.C.

20555 mn cgge'

v es J

asu e9W b

IE Information Notice No. 79-36 Date: December 31, 1979 Page 1 of 1 COMPUTER CODE DEFECT IN STRESS ANALYSIS OF PIPING ELB0W Description of Circumstances:

The NRC was informed on December 17, 1979 that a computer code, NUPIPE, used in the stress analysis of piping systems contained a defect which could result in incorrect stress values at one end of piping elbows.

Inis defect was iden-tified from discussions with a user of NUPIPE and the NUPIPE code developers.

The stress calculation error can occur when a flexible joint is modeled at the end of an elbow (ELBOW-ELAST0JT connection in NUPIPE terminology).

This defect in the NUPIPE code is in the transformation of the loads in the ELAST0JT coordin-ate axis to the piping ELBOW coordinate axis.

The incorrect coordinate axis transformation may incorrectly interchange the torsion and bending moment loads on the piping elbow.

This can result in the incorrect assignment of the stress intensification factor for the individual moments.

The correct stress may be higher or lower than calculated by NUPIPE, depending on the loading condition.

Four conditions must exist for the possibility of the calculation of an incorrect stress in the NUPIPE code:

1.

an USAS B31.1.0 - 1967 Code analysis is being done, and 2.

an ELBOW-ELAST0JT connection exists, and 3.

an absolute sum of two load cases is being calculated, and 4.

the ELBOW torsional moment axis does not align with the ELAST0JT local x-axis.

Possible users of the NUPIPE code include the code developer, Stone and Webster, EG&G (Idaho Falls), and those using the Cybernet system.

The NRC is currently reviewing the extent of usage of the NUPIPE code and the generic implications for other facilities.

There is a potential for a similar defect to occur in other piping analysis computer codes.

This Information Notice is provided as early notification of a possible signif-icant matter.

It is expected that recipients will review the information for possible applicability to their facilities.

No specific action is requested in response to this Information Notice.

If NRC evaluations so indicate, further licensee actions may be requested or required.

If you have any questions regarding this matter, please ccatact the Director of the appropriate NRC Regional Office.

No written response to this IE Information Notice is required.

1745 066

ENCLOSURE 2 IE Information Notice No. 79-36 Date:

December 31, 1979 Page 1 of 1 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued to Notice No.

Issued 79-12A Attempted Damage to New 11/9/79 All Fuel Facilities, Fuel Assemblies Research Reactors and Power Reactors with an Operating License (OL) or Construction Permit (CP) 79-27 Steam Generator Tube 11/16/79 All Power Reactor Faci-Rupturas at Two PWR liti:.. with an OL or CP Facilities 79-28 Overloading of Structural 11/16/79 All Power Reactor Faci-Elements Due to Pipe Support lities with an OL or CP Loads 79-29 Loss of Nonsafety Related 11/19/79 All Power Reactor Faci-Reactor Coolant System In-lities with an OL or CP strumentation During Operation 79-30 Reporting of Defects and 12/6/79 All Power Reactor Faci-Noncompliances, 10 CFR lities with an OL Part 21 or CP 79-31 Use of Incorrect Amplified 12/13/79 All Power Reactor Faci-Response Spectra (ARS) lities with an OL or CP 79-32 Separation of Electrical 12/21/79 All Power Reactor Faci-Cables for HPCI and ADS lities with an OL or CP 79-33 Improper Closure of Primary 12/21/79 All Power Reactor Fr.ci-Containment Access Hatches lities with an OL or CP 79-34 Inadequate Design of Safety-12/31/79 All Power Reactor Faci-Related Heat Exchangers lities with an OL or CP 79-35 Control of Maintenance 12/31/79 All Power Reactor Faci-and Essential Equipment lities with an OL or CP 1745 067