Advises That Operation Under Tech Specs 3.6.1.1 & 3.6.1.4 Conforms W/Nrc Interim Position Re Qualification of Containment Purging & Venting Valves
ML19256G131
Person / Time
Site: North Anna Dominion icon.png
Issue date: 12/20/1979
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton
Office of Nuclear Reactor Regulation
References
922-103079, NUDOCS 7912270494
Download: ML19256G131 (2)


Text

.

D**D T Q' A kifh wo o

VrnorsIA Er.ucruxc Ann Powna Cosmxy RICHMOND,VIBOINIA QUn61 December 20, 1979 Mr. Harold R. Denton, Director Serial No.

922/103079 Office of Nuclear Reactor Regulation P0/FHT:baw Attn:

Mr. A. Schwencer, Chief Docket No.

50-338 Operating Reactors Branch #1 License No. NPF-4 Division of Operating Reactors U. S. Nuclear Regulatory Commission Washington, D. C.

20555

Dear Mr. Denton:

North Anna Power Station Unit 1 Containment Purging and Venting During Normal Operation We have reviewed your letter of October 30, 1979 on the above subject and have determined that we presently operate in conformance with your Interim Position.

North Anna Technical Specifications, section 3.6.1.1., Primary Containment Inte-grity, require that the purging and venting valves (MOVs-HV 100A,100B, 100C, 100D, 101 and 102) be closed when the reactor coolant temperature is above 200*F.

Technical Specifications, section 3.6.1.4., containment Internal Pressure, require the contad~nt to be subatmospheric when the reactor coolant system temperature is above 200*F.

For the containment to be maintained subatmospheric, the purging and venting valvas must be closed.

Since these valves are maintained in the closed position under any reactor coolant system temperature condition that could result in containment pressurization during a DBA-LOCA, we believe no further action is required.

Very truly yours, h > &,.,$ / a f i c w, &

n C. M.

Stallings Vice President-Power Supply and Production Operations cc:

Mr. James P. O'Reilly Region II 1644 340 Y9 f

g 7912270

COMMONWEALTH OF VIRGINIA

)

)

S. S.

CITY OF RICHMOND

)

Before me, a Notary Public, in and for the City and Common-wealth aforesaid, today personally appeared C. M. Stallings, who being duly sworn, made oath and said (1) that he is Vice President-Power Supply and Production Operations, of the Virginia Electric and Power Company, (2) that he is duly authorized to execute and file the foregoing statements in behalf of that Company, and (3) that the statements are true to the best of his knowledge and belief.

Given under my hand and notarial seal this 24'rdday of D s e e a },, c'

,)979 My Commission expires Jo,,,, g y s) 20 / F4 /

YtllW ksY Notary Public (SEAL) 1644 341