OPFFf, TING DATA FFFORT DOCFET rJO.

50-302 DATE DECEMDER 5 COMPLETED by:

M W CULVER TELEPHONE (904) 795-6486

- QE 3 A T ] t_T. S T AIUS l

I tJO T E S I

AIT NAnt C R v ST AL PTVER N3 l

l

'EFORTING PERIOD 11/1/79 + 11/3II/70 I

I LICEtJCED THE RnAL POWER (MWT) 2452 I

I "AME PLATC PnT itG (GPO55 MWE) 000 I

I IiE E 10tJ f.LE C T F I C AL P A T I rJG (NET MWE) 825 I

I

.M I nU M DEFENDABLE CAPACIT( (GROSS MWE) 835 I

I nA/IMUM DEFENDADLE CAPACITY tNET MWE) 707 i

Ir CHANGET. OCC'IR IN CAPACIT( FATINGS ( ITEh3 NilMBER 3 THROUGH 7) SINCE LAST REFORT, GIVE F E ASON' _ - _ _ _ _ -. _ _ _ _. _ _ _ _ _ _ _ - - _ _ _ _ - - _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - - _ _ - - -. _ _ _ - _ _ - -. - _ - _ _ _ _

FOWER I.EVEL TO WHICH RESTRICTED.IF ANY(tJET nWE): NONE PCASONS FOR PESTRICTIONS, IF ANY _-_-._________.__-__-_-__-._._.__-______-_.___- _--.____

THIS MONTH YR.-TO-DATE CUMULATIVE 11 HOURS Irf RE PORTING PERIOD 720 0016 23032 MJ h[ E F Or HOUF5 PEACTOR WA5 CRITICAL 720.0 4561.9 14410.1 K T AC T r.P FTT.FPVE SHUTDOWN HnUPS 0.0 743.5 1116.'

.4, HTK GL 4hATOR. ;N - L. J NE 7 0. 0 4435.0 1MTo 15-Ut!I T REGERVE SHUTDOWN HOURS 0.0 0.0 0.L 16 GROSS THEPMAL ENERGY GENERATED (MWH) 1726425 13601623 34278771 17 GRO35 ELECTRICAL ENEPGY GENERATED (hWH) 583315 3385639 103S%85 13.

NEl ELECTRICAL ENEPGY GENERATED (MWH' 555728 3201503 9031568 1 '; UNIT SERVICE FACTOP 100.0 /*

55.3 /+

58.7 /t IIN I T

.W., T L Ab lL I T Y FACTOR 100.0*/*

55.3./.

58.7-/*

UNI-CAI..:'i FACIOF (USING hDC NET)

C6.0 /*

50.1 /-

51.n- -

Hi
93. M /
  • 40.4*/*

SL.a 36..

3 l bH T F0r ciD bbiAGE FsiE 0.0 /.

25.7c 24 GHuiDOWrd %rHFDU yE.THE NEDT 6 MONTHS (T F DAT A D. DURATION Or EACH) ce m.-t

'y D OFtef e-_ -

_ _ _.ff.dep. Wreh_m --_- ------ -. ---- -- _ -. _ _ -- - _ - _

EN REPORT FERIOD. ESTIMATED DATE OF STARTUP:.. ---__ __.- - -________

25 ;r SHUT DOWN AT

, t, UrJ I T S l tJ TEST STATUS (PRIOR TO COMMEPCIAL OPERATION)

FORECAST ACHIEVED INIT!AL LPITICALITY 1/14/77 INITIAL ELEETRICITY 1/30<77 COMnEPCIAL OPERATION 3/13/77 1608 158 m yg mg q g

M u

A h, r

q912180

/

., %.e.e..

a,

.g.

AVER AGE D AILY UNIT POWER LEVEL DOCKET NO.

50-302 FLCRP-3 UNIT DATE 12/10/79 COMPLETED BY M. W. culver TELEPilONE (904)795-6486 MONTil NOVEMBER DAY AVER AGE DAILY POWER LEVEL DAY AVER AGE DAILY POWER LEVEL (MWe Net t (MWe-Net!

790 17 795 2

799 18 795 3

784 in 789 4

793 20 761 786 5

21 723 43 6

2; 771 7

657 23 792 g

784 24 786 g

789 25 790 10 793 26 786 786 27 788 790 12 28 797 l3 808 29 7AA 34 662 774 30 15 667 3

i.

792 INSTRUCTIONS On this format. hst the cerage dr v -

ine! m MWe. Net for each day in the reporting month. Compute to w

the neareu whoie meF'*31 1608 159

""77' pee p m gyg feeM of JLllnim M

r e e l

h l

t g

o n

r d

s6 r

g i

nt n

G eR e

n e

a vA s

i eb o

I 0

l6 nd n

t h

W d c R

u i e ed r

a Rt nF e l

Cb an d n e;

l sS i

n N

1 7

l i

2 f

0 P n a

ma na t x l aMd ae e e

3 R

i

.7 e

o ao i w nrh v

e i p

e

- r f u hl cd wb c

eadTo e el s

s i e

?

)

gc e

r. ssh l

nt nF rc a

0 i

5 F

1

.A i

at t esoit rr s

ioa eI u

ak DiR o

c Mn hd a

l tk h

ee.

o n

rc aaanTnl t yw n tufLE S

c

(

aa i o swea ol al a

r or e

e v

c L

e ti n

al l

oel rt ts o

nf I m

c e

od p

or o. t rHae noi o

r I

r a

.EEYE e nr t e ee t edt rf t ul n ta ts i S

O D O i u t

rr s e einWnli r ep MTBN ron c ea e

ent et roF aoa Gah r

e N A A e

i I

T P i R ul ow uecuad c mrr ti e tn1 iN e

N D Co pS R ti I

l Ei

&t d o t

dd ed e e

td E

)

r b

s s

nr H nlhd n bi P

>r u

c t K

E F

eAn ni nk norn i et eor h

tnv1 L

e6 I

C N L

s e

E u

s o

oa ocooWav scS xr O U P

o EfEE0 i ;.i e i

ciFgeno M

I T

a e

D M

C P

tT xtl t "A d t

l ol n d

r O

oc c

cB a cie e

c4b 5

u u;

u" nuS kr ah t

C d rrdk

.d ad yneyrt s

eeeead en enb alld u

rst reerid ri tll n

j na l r e

d oaro d

rewr irst rl enrie a

ed eeaek aeesit t t n wn wbpwacwvuanrai s

o o "D oueoeooearoaea a

P c" Pt rPllPl cd c pH g w

S N

m)

O H

H H

H ar n C

C C

C mci I

%3U X

X X

X aSl T

a C

r p

!S E

E E

E c

U T

T T

T StaE cix D

H H

H H

R

.l l

m (r E

a a E

duu oe R

B o nnt h R

M ha a ut E

E g7C C

C C

H e M M A. O t

W V

E,, @

H H

H H

Ml 234 O

O N

P 1

D 1

N T

A NO r

S e

s N

M et t

A A

A A

s nr W

T n e o e v p

/

/

/

/

O R

c n

i. F e N

N N

N o

D O

R ta P

i 1

I E

n U

im R

l i

S ax l

~hk5 gd F

i N

Ysg A

A A

A

)n e

)

/

/

/

/

ia n

in U

s h2j N

N N

N lp c

lp e

a x

niL x

E ic&

I o

(t t

E 345 s

e e r

ig r

B A

A H

uT n

o) r a

lif tsi r

e net n ao F

Ri sI i ai a

e yT a l lp r

l a

5 c

?8E 7

tnn 2

4 3

2 mn int o t

nx 7

r ea gor r 9

8 5

s io1 35$

mt

(

el at a

pt el a ninu ur i r er o uif gemeh s qa e e pd pt aEMRROA.OO e -

h*

F F

F F

RABCDliFGIl i

s a

6 4

0 0

e 0

1 2

3 1

1 1

1 la 1

1 1

1 D

9 9

9 9

d 7

7 7

7 le du ed c e roh c

D 2

3 4

5 F S

)

N".

2 2

2 2

7 FS 7

9 9

9 9

/

7 7

7 7

3 O O " C O

'l

i MONTHLY STATUS REPORT REFUELING INFORMATION REQUESf 1.

Name of Facility:

Crystal River Unit 3 2.

Scheduled date of next refueling, shutdown:

Apri l, 1980.

3.

Scheduled date for restart following refueling:

June, 1980.

4.

Will refueling or resumption of operation thereafter require a technical sr cification change or other license amendment? Yes.

In general, changes to the CR #3 technical specifications will include:

a.

Moderator Temperature Coefficient (3.1.1.3) b.

Control Rod Insertion Limits (3.1.3.6) c.

Control Rod Group Assignments (3.1.3.7) d.

Axial Imbalance Limits (3.2.1) e.

Refueling Boron Concentration (3.9.1)

These specifications will be reviewed and changed as necessary based on the reactivity of the second cycle as compared to that of the first cycle.

S.

Scheduled date(s) for submitting proposed licensing action and supporting information:

Februa ry, 1980.

6.

Impartant licensing considerations associated with refueling, e.g.,

new or dif ferent fuel design or supplier, unreviewed design or performance analysis methods, significant changes in f uel design, or new operating procedures.

Florida Power Corporation is presently discussing with the NRC staf f our intent to request that the power level of CR #3 be raised from the present level of 2452 MW (t) to the ultimate core power level of 2544 MW (t) as described in the CR #3, FSAR. FPC submitted, on February 28, 1979, our reload report justifying Cycle 2 operation of CR #3 at 2544 MW (t). On May 25, 1979, FPC modified its Cycle 2 reload report justifying continued operation of 2452 MW (t).

It is our intent to continue our discussions with the NRC in order to obtain the power upgrade at a later date.

7. ' The number of fuel assemblies (a) in the core and (b) in the spent fuel storage pool.

a.

17/ assemblies b.

60 assemblies, 8.

The present licensed spent fuel pool storage capacity and the size of any increase in licensed storage capacity thr.c has been requested or is planned, in number of fuel assemblies.

a.

Present storage capacity - Pool A - 120 plus 8 f ailed fuel assemblies.

Pool B - 120 plus 8 failed fuel assemblies.

WPSemhW01

s a
w..

m.

8.

(Continued) b.

Filed request on January 9,1978 with NRC concerning expansion of Pool A fran 120 to 544 assemblies plus 6 failed fuel assemblies and expansion of Pool B from 120 to 609 assemblies. Expansion of Pool A is to occur at the refueling in April,1980.

The Pool B expansion will occur at a Ifter refueling outage (approximately 1986).

Additional detailed design information concernin9 our fuel pool expansion was submitted to the Commission on March 3 and March 28, 1978, January 18, 1979, March 16, 1979, June 29, 1979, September 5, 1979 and October 10, 1979.

9.

The projected date of the last refuelin9 that can be discharoed to the spent fuel assuming the present licensed capacity.

1981-Ir 1.

1608 162 WPSemhW01 C5

.