Forwards IE Bulletin 79-17, Pipe Cracks in Stagnant Borated Water Sys at PWR Plants. No Action Required
ML19256B542
Person / Time
Site: Humboldt Bay
Issue date: 07/26/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Crane P
PACIFIC GAS & ELECTRIC CO.
References
NUDOCS 7908060144
Download: ML19256B542 (1)


Text

,

s r

p * ** %

4'

,c, UNITFD STATES

'[ 'y, r 7 ' j NUCLEAR REGULATORY COMMISSION REGION V d~.E t

[

1990 N CALIFORNI A BOULEVARD o,

p.

,o?

SulTE 202, WALNUT CRE E K PLAZA

'3

'b o...e WALNUT CR E E K. CALIFORNIA 94596 July 26, 1979 Docket No. 50-133 Pacific Gas and Electric Ccmpany 77 Beale Street San Francisco, California 94106 Attention:

Mr. Philip A. Crane, Jr. '

Assistant General Counsel Gentlemen:

The enclosed Bulletin No. 79-17 is forwarded to you for information. No written response is required. However, the potential corrosion behavior of safety related systems as it regards your plant over the long term should be taken into consideration.

If you desire additional infonnation concernirg this matter, please contact this office.

Sincerely,

.i i. ~[ I a --- -.-

R. H. Engelken Director

Enclosure:

IE Bulletin No. 79-17 cc w/ enclosure:

W. Barr, PG&E E. Weeks, PGSE, Humboldt Bay W. A. Raymond, PG&E

/d/O

)

~908080 4

p)

UNITED STATES NUCLEAR REGULATORY CORtISSION CFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D. C.

20555 July 26, 1979 IE Bulletin No,. 79-17 PIPE CRACKS IN STAGNANT BORATED WATER SYSTEMS AT PWR PLANTS Description of Circumstances:

During the period of November 1974 to February 1977 a number of cracking incidents have been experienced in safety-related stainless steel piping systems and portions of systems which contain oxygenated, stagnant or essentially stagnant borated water. Metallurg%1 investigations revealed these cracks occurred in the weld heat affected ane of 8-inch to 10-inch type 304 material (schedule 10 and 40), initiating on the piping I.D. surface and propagating in either an intergranular or transgranular mode typical of Stress Corrosion Cracking. Analysis indicated the probable corrodents to be chloride and oxygen contamination in the affected systems.

Plants affected up to this time were Arkansas Nuclear Unit 1, R. E. Ginna, H.B. Robinson Unit 2, Crystal River Unit 3, San Onofre Unit 1, and Surry Units 1 and 2.

The NRC issued Circular 76-06 (copy attached) in view of the apparent generic nature of the problem.

During the refueling outage of Three Mile Island Unit I which began in February of this year, visual inspecticns disclosed five (5) through-wall cracks at welds in the spent fuel cooling system piping and one (1) at a weld in the decay heat renoval system. These cracks were found as a result of local boric acid build-up and later confimed by liquid penetrant tests.

This initial identification of cracking was reported to the NRC in a Licensee Event Report (LER) dated May 16, 1979. A preliminary metallurgical analysis was performed by the licensee on a section of cracked and leaking weld joint from the spent fuel cooling system.

The conclusion of this analysis was that. cracking was due to Intergranular Stress Corrosion Cracking (IGSCC) originating on the pipe I.D.

The cracking was localized to the heat affected zone where the type 304 stainless steel is sensitized (precipitated ca.rbides) during welding.

In addition to the main through-wall crack, incipient cracks were observed at several locations in the weld heat affected zone including the weld root fusion area where a miniscule lack of fusion had occurred. The stresses responsible for cracking are believed to be primarily residual welding stresses in as much as the calculated applied stresses were found to be less than code design limits.

There is no conclusive evidence at this time to identify those aggressive chemical species which promoted this IGSCC attack.

Further analytical efforts in this area and on other system welds are being pursued.