Forwards Response to Unresolved Items Re Inservice Insp Program from 781115-6 Meetings.Provides List of Valves Requiring Inservice Testing & Justification for Deleting Certain Valves from the Insp Program
ML19256B163
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 01/15/1979
From: David Williams
ARKANSAS POWER & LIGHT CO.
To: Reid R
Office of Nuclear Reactor Regulation
References
1-019-6, 1-19-6, NUDOCS 7901240188
Download: ML19256B163 (21)


Text

i s.

~-

ARKANSAS POWER & LIGHT COMPANY POST OFFICE BOX 551 LITTLE ROCK. ARKtNSAS 72203 (501) 371-4000 January 15, 1979 1-019-6 Director of Nuclear Reactor Regulation ATTN:

M.

R. 'd. Reid, Chief Operating Reactor Branch #1 U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Arkansas Nuclear One - Unit 1 Docket No. 50-313 License No. DPR-51 Inservice Testing Program (File:

3065)

Gentlemen:

In October, 1977, we submitted our Inservice Inspection and Inservice Testing Programs which incorporated the 1974 AoME B6PV Code,Section XI through the Summer 1975 Addenda. Your April 20, 1978, letter granted interim approval, and on September 13, 1978, you requested additional in-formation in order to complete your evaluation. Attached are responses to those items c the IST Program which were not resolved during the meet-ings at Arkansas Nuclear One (ANO) on November 15 and 16,1978. These responses include a list of valves requiring IST (Enclosure 2), Relief Requests (Enclosure 1) for the equipment we feel that we cannot reasonably inspect and/or test, and explanation of why some valves cannot be quarterly stroked (fully or partially) during normal plant operation (Enclosure 3),

and justification for the deletion of certain valves from our IST Program.

Ver truly yours, W

v/

Daniel H. Williams Manager, Licensing DHW: ERG:nj 7ef 790124 o/#f 9

__ e_ m1_e e e_

ENCLOSURE 1 INSERVICE INSPECTION RELIEF REQUESTS 1.

Component:

Reactor Coolant Pumps ASME Class 1 Table IWB-2600 Item Category Description B.5.6 B-L-1 Pump Casing Welds Impractical Code Requirement: Table IWB-2500 Category B-L-1 "The volumetric examination of 100% of the. pressure-retaining welds in at least one pump in each group of pumps performing similar~

functions in a system."

Raason for Relief:

The examination of reactor coolant pump casing welds by means of UT is, at present, beyond the " State of the Art".

The use of RT is not practical, since the radioactive source must be placed inside the reactor coolant pump.

Such an examination would expose personnel involved to dangerously high radiation IcVels.

Surface preparation and decontamina-tion problems prohibit surface examination.

Alternate Examination:

A visual examination for evidence of leakage, structural distress, or corrosion.

2.

Component:

Buried Portions of the Service Water System ASME Class 3 Impractical Code Requirement:

IWD-2600(b)

"A. system pressure. test in lieu of visual examinacion."

Reasons for Relief:

1.

Valves provided for isolation were not designed for pressure testing and are not adequate for this service.

2.

S ufficient service water flow during normal operation. assures suf ficient flow during any emergency condition. (See FSAR s ection 9.3).

Alternate Examination:

Confirm service water flow is adequate during normal operation.

3.

Component: CF 1 A S B Valvb Category: C P G ID # 230 t

Impractical Code Requirement:

INV-3520 (b)

"Normally closed check valves... shall be full-stroke exercised during each cold shutdown."

Reason for Relief:

Full-stroking of these valves during cold shutdown could delay

. start-up more than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and create as much as 28,000 gallons of liquid waste.

Testing in lieu of Code Requirement:_

.These valves shall be partial. stroke exercised during each refueling outage.

4.

Component: BS 4ASB Valve Category: C P G ID #236 Impractical Code Requirement:

IWV-3520 (b)

"Normally closed check Valves...shall be full-stroke exercised during each cold' shutdown."

Reason for Reli.cf:

These valves are immediately upstream of the RB spray nozzels.

Water Flow cannot be used for stroking these check valves because the system is open ended into containment.

Alternate test procedures require more manpower and equipment than is normal.ly available during cold shutdown.

Testing in lieu of Code Requirement:

These valves shall be partial-stroke exercised during each re-fuelinF outage.

9

Page 1 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING 1

LIrllTING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE PROCEDURE VALVI; N_0.

_SYSTEtt DESCRI_PTION (IN)

TYPE CAT CLASS _ POS POS tit!E EXERCISE LEAK EXERCISE _

PSV-1001 RCS Relief Pzr 3

Relief C

1 C

0 NA-CODE NA 1401.03 PSV-1002 RCS Relief Pzr 3

Relief C

1 C

0 NA CODE NA 1401.03 Core Flood 1104.01 CF-1A RCS Discharge 14 Check

  • C 1

C 0

NA

+

NA Supp. 1 Core Flood 1104.01 CF-1B RCS Discharge 14 Check C

1 C

0 NA

+

NA Supp. 3 1104.04 DH-13A RCS LP Injection 12 Check C

1 C

0 NA CSD*

NA Supp. 3 1104.04 Dil-13B RCS LP Injection 12 Check C

1 C

0 NA CSD

  • NA Supp. 3 l

1104.01 Dil-14A RCS LP Injection 14 Check C

1 C

0 NA CSD*

NA Supp. 1 1104.01 Dil-14B RCS LP Injection 14-Check C

1 C

0 NA CSD

  • NA Supp. 1 1104.01 DIl-17 RCS LP Injection 8

Check C

1 C

0 NA CSD

  • NA Supp. 1 1104.04 Dif-18 RCS-LP Injection C

Check C

1 C

0 NA CSD

  • NA Supp. 1 1104.02 t!U-34A RCS IIP Injection 2

Check C

1 C

0 NA CSD

Check C

1 C

0 NA CSD

  • NA Supp. 5 Revision'0 1005.08 December 19, 1978

Page 2 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING

}

~~

~~

f LIMITING SIZE

[WV NOR ACC CLOSE TESTING PROCEDURE PROCEDURE VALVE NO._

SYSTEM DESCRIPTION (IN)_

TYPE CAT CLASS POS POS TIME EXERCISE LEAK EXERCISE 1104.02 MU-34C RCS IIP Injection 2

Check C

1 C

0 NA CSD*

NA Supp. 5 1104.02 MU-34D RCS

]IP Injection 2

Check C

1 C

0 NA CSD*

NA.

Supp. 5 Main Steam to 1106.06 CV-2617 MS EFW Turbine 4

Gate

  • B 2

C 0

70 see CODE NA Supp. 4 Main Steam to 1106.06 CV-2666 MS EFW Turbine Bypass 3

Gate B

2 C

NA 80 see CODE NA Supp,. 3 Main Steam to' 1106.06 CV-2667 MS EFW Turbine 4

Gate B

2 C

0 70 see CODE NA Supp. 3 Main Steam 1102.01 CV-2691 MS Isolation 36 Gate B

2 0

C 10 sec CSD

  • NA Supp. E

'tr in Steam 1102.01 CV-2692 MS lsolation 36 Gate B

2 0

C 10 see CSD

  • NA Supp. E,

PSV-2684 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01 PSV-2685 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01 PSV-2686 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01 PSV-2687 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01 PSV-2688 MS Relief Main Steam l 10 Relief C

2 C

0 NA CODJ NA 1404.01 Revision'0 1005.08 December 19, 1978 i

Page 3 of 15 ENCLOSURE 2 UNIT 1 V'TNES REQUIRING INSERVICE TESTING LIrlITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE PROCEDURE VALVE NO.

SYSTEM DESCRIPTION (IN)

TYPE CAT CLASS POS P03 TIME EXERCISE LEAK EXERCISE PSV-2689 t1S Relief Main Steam 10 Relief C

2 C

0 NA CODE

.NA 1404.01 l

PSV-2690 MS Relief Main Steam 10 Relief C

2 C

.0 NA CODE NA 1404.01 PSV-2691 MS Relief Main Steam 10 Reliel C

2 C

0 NA CODE NA 1404.01 PSV-2692 MS Relief Main Stean 10 Relief C

2 C

0 NA CODE NA 1404,.01 PSV-2693 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01 PSV-2694 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01 l.

PSV-2695 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01,

PSV-2696 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01 PSV-2697 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01 PSV-2698 MS Relief Main Steam 10 Relief C

2 C

0 NA CODE NA 1404.01.

I PSV-2699 MS Relief Main Steam 10 Relief C

2 C

0 NA' CODE NA 1404.01 1304.23 1304.70

' CV-1214 MU RCS Letdown 2

Ca t:-

A 2

0 C

20 sec CSD*

Table 3 Supp. 2 g

Revision'0 1005.08 December 19, 1978

Page 4 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING

]-

LIMITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE' PROCEDURE

_ VALVE NO.

SYSTEM DESCRIPTION (IN)

TYPE CAT CLASS POS POS

' TIME EXERCISE LEAK EXERCISE 1304.23 1J04.20 CV-1216 MU RCS Letdown 2

Gate A

2 0

C 20 see CSD*

Table 3 Supp. 2 l ---

CSD*

1104.02 CV-1219 MU IIP Injection 2

Globe B

2 C

0 20 see NA Supp. 1 CBD

  • 1404.02 CV-1220 MU IIP Injection 2

Globe B

2 C

0 20 see NA-Supp. 1 CSD*

1403.23 1304.70 CV-1221 MU RCS Letdown 2

Gate A

2 0

C 20 sec Table 3 Supp. 1 SD*

1104.02 CV-1227 MU HP Injection 2

Globe B

2 C

0 20 sec NA Supp. 1 CSD*

1104.02 CV-1228 MU IIP Injection 2

Globe B

2 C

0 20 see NA Supp. 1 l

1304.70 CV-1234 MU RCS Makeup -

2 Gate B

2 0

C 20 see CODE NA Supp. le 1304.23 1104.02 CV-1270 MU RCP Seal Bleed Off 1

Globe A

2 0

C 20 sec CSD*

Table 3 Supp. 5 1304.23 1104.02 CV-1271 MU-RCP Seal Bleed Off 1

Globe

'A 2

0 C

20 see CSD

  • Table 3 Supp. 5 1304.23 1104.02 CV-1272 MU RCP Seal Bleed Off 1

Globe A

2 0

C

'20 sec CSD

  • Table 3 Supp. 5 1304.23 1104.02 CV-1273 MU RCP Seal Bleed Off 1

Globe

  • A 2

0 C

20 see CSD

  • Tabic 3 Supp. 5 1304.23 1104.02 CV-1274 MU RCPSealBleedOffj 1 Globe A

2 O

C 20 see CSD

  • Table 3 Supp. 5 Revision 0 1005.08 December 19, 1978

Page 5 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING LIMITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE' PROCEDURE VALVE NO.

SYSTEM DESCRIPTION (IN>

TYPE CAT CLASS POS POS TIME EXERCISE LEAK EXERCISE 1104.02 CV-1300 MU MU Pump Recirc 2

Globe A

2 0

C 20 see CSD*

NA Supp. 5 1104.02 CV-1301 MU MU Pump Recirc 2

Globe A

2 0

2 20 sec CSD*

NA Supp. 5 1104.02 MU-19A MU Pump Discharge 4

Check C

2 C

0 NA CODE NA Supp. 4 1104.02 l HU Pump Discharge.

4 Check C

2 C

0 NA CODE NA Supp. 3 MU-19B 1104.02 MU-19C MU Pump Discharge 4-Check C

2 C

0 NA CODE NA Supp. 2 1304.70 CV-1400 Dil Pump Isolation 10 Gate B

2 C

0 20 see CSD

  • NA Supp. 2 1304.70 CV-1401 Dl!

Pump Isolation 10 Gate B

2 C

0 20 see CSD

  • NA Supp. 2 1304.70 CV-1405 Dli Pump Suction 14 Gate B

2 C

0 90 sec CSD

  • NA Supp. 2 1304.70 CV-1406 Dii-Pump Suction 14 Gate

'B 2

C 0

90 see CSD

  • NA Supp. 2 1104.04 CV-1407 Dli BWST Outlet 14 Gate B

2 C

0 20 see CODE NA Supp. 1 1104.04 CV-1408 DII BWST Outlet 14 Gate

  • B 2

C 0

20 see CODE NA Supp. 2 1104.04 711-2A Dil Pump Discharge 10 Check C

2 C

0 NA CODE NA Supp. 1 g

Revision 0 1005.08 December 19, 1978

Page 6 of 15

. ENCLOSURE 2' UNIT 1 VALVES REQUIRIP: INSERVICE TESTING LIMITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE ^

PROCEDURE (VALVE NO.

SYSTEM DESCRIPTION (IN)

TYPE CAT CLASS POS POS TIME EXERCISE LEAK EXERCISE 1104.04 DH-2B Dil Pump Discharge 10 Check C

2 C

0 NA CODE NA Supp. 2 1104.05 CV-2400 BS Puiup Discharge.

8 Globe B

2 C

0 20 sec CODE NA Supp. 4 1104.05 CV-2401 ES Pump Discharge 8

Globe B

2 C

0 20 sec CODE NA Supp. 4 Stop 1104.05 CV-2410 BS N Thio Sulfate 4

Check C

2 C

0 NA CODE NA Supp. 4 Stop 1104.05 CV-2411 BS Na Thio Sulfate 4-Check C

2 C

0 NA CODE NA Supp. 5 1104.05 BW-6A

,BS Pump Suction 10 Check C

2 C

0 NA CODE NA Supp. 3 1104.05 BW-6B BS Pump Suction 10 Check C

2 C

0 NA CODE NA Supp. 9 BS-4A BS Pump Discharge 8

Check C

2 C

0 NA

+

BS-4B BS-Pump Discharge 8

Check

'C 2

C 0

NA

+

1102.01 CV-2630 FW MFW 18 Ga'e B

2 0

65 sec CSD

  • NA Supp. E 1102.02 CV-2680 FW MFW 18 Gate B

2 0

65 sec CSD

  • NA Supp. E 1102.02 Check C

2 0

C NA CSD

  • NA Supp. 2

} 18

, FW-7A FW FEV Revision 0 1005.08 December 19, 1978

Page 7 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING LIMITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE' PROCEDURE

_ IN)

_ TYPE CAT CLASS POS POS TIME EXERCISE LEAK EXERCISE

(

VALVE NO.

, SYSTEM DESCRIPTION 1102.02 FW-7B FW MFW 18 Check C

2 0

C NA CSD*

NA Supp._2 1106.06 FW-13A EFW EFW 4

Check C

2 C

0 NA CSD*

NA Supp. 4 1106.06 FW-133 EFW EFW 4

Check C

2 C

0 NA CSD*

NA Supp. 4 1106.06 CV-2617 EFW MS to EFW Pump.

4 Gate B

2 C

0 70 see CODE NA Supp. 4 1106.06

~

CV-2620 EFW CV-2626 Bypass 4-Gate B

2 C

0 30 see CODE NA Supp. 3 1106.06 CV-2626 EFW EFW Control 4

Gate B

2 C

0 30 see CODE NA Supp. 3 1106.06 CV-2627 EFW CV-2670 Bypass 4

Gate B

2 C

70 see CODE NA Supp.e4 1106.06 CV-2670 EFW EFW Control.

4 Gate B

2 C

0 30 sec CODE NA Supp. 3 1404.05 CV-1616 CA-NaOH Tank Outlet 4

Gate B

2 C

0 30 sec CODE NA Supp. 2 1404.05 CV-1617 CA NaOH Tank Outlet 4

Gate B

2 C

0 30 sec CODE NA Supp. 2 Stop 1404.05 CA,-61 CA NaOH Discharge 4

Check

'C 2

C 0

NA CODE NA Supp. 2 Stop 1404.05 CA-62 CA NaOH Discharge 4

Check C

2 C

0 NA CODE NA Supp. 2 Revision 0 1005.08 December 19, 1978

Page 8 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING l

LIrllTING SIZE IWV NOR ACC -

CLOSE TESTING PROCEDURE' PROCEDURE VALVE NO.

SYSTEf!

DESCRIPTION (IN)

TYPE CAT CLASS POS.

POS TIrlE EXERCISE LEAK EXERCISE Stop 1104.05 CA-90A CA Na Thio Discharge 4

Check C

2 C

0 NA CODE NA Supp. 2.

Stop 1104.05 CA-90B CA Na Thio Discharge 4

Check C

2 C

0 NA CODE NA Supp. 1 Stop 1104.02 BW-2 BW HU Pump Suciion 6

Check C

2 C

0 NA CSD*

NA Supp. 5 Stop 1104.02 BW-3 BW MU Pump Suction 6

Check C

2 C

0 dA CSD*

NA Supp. 5 1104.04 BW-4A BW BWST Outlet 14 Check C

2 C

0 NA CODE NA Supp. 1 1104.04 BW-4B

,BW BWST Outlet 14 Check C

2 C

0 NA CODE NA Supp. 2 t

1304.23 1304.70 CV-2214 ICW Letdown Cooler Iso 8

Gate A'

2 0

C 20 see CSD*

Table 3 Supp. 2' 1304.23 1304.70 CV-2215 ICW Letdown Cooler Iso 8

Gate A

2 0

C 90 see CSD*

Table 3 Supp. 2 CRD/RCP 1304.23 1304.70 CV-2220 ICW Cooling Iso 8

Cate A

2 0

C 90 sec CSD*

Table 3 Supp. 2 CRD/RCP 1304.23 1304.70 CV-2221 ICW Cooling Iso 8

Gate A

2 0

C 60 sec CSD*

Table 3 Supp. 2 Letdown 1304.23 1304.70 CV-2233 ICW Cooler Iso 8

Gate

'A 2

0 C

60 sec CSD*

Table 3 Supp. 2 1304.23 1304.70 CV-2234 ICW RCP Motor Iso I8 Globe A

2 0

C 30 sec CSD*

Table 3 Supp. 2 Revision 0 1005.08 December 19, 1978

Page 9 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING

~

~~

lit!ITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE' PROCEDURE VALVE NO.

SYSTEM DESCRIPTION (lN)

TYPE CAT CLASS POS POS title EXERCISE LEAK EXERCISE 1304.23 1304.70 CV-2235 ICW CRD Iso 3

Globe A

2 0

C 30 sec CSD*

Table 3 Supp. 2 1304.23 1304.70 CV-1052 CZ Quench Tank Drain 3

Gate A

2 0

C 1 sec CODE Tabie 3 Supp. 2 1304.23 1304.70 CV-1053 CZ Quench Tank Drain 3

Gate A

2 0

C 20 see CODE Table 3 Supp. 2 1304.23 1304.70 CV-1054 SS Quench Tank Drain 1

Gate A

2 0

C 30 sec CODE Table 3 Supp. 2 1304.70 CV-1814 SS Pz Steam Sample Globe B

1 0

C 20 sec CODE NA Supp. I 1304.70 CV-1816 SS Pz Water Sample Globe B

1 0

C 20 sec CODE NA Supp. 1 1304.23 1304.70 CV-1845 SS Quench Tank Sample Globe A

2 0

C 20 sec CODE Table 3 Supp. le 1304.23 1304.70 CV-5611 FIRE RB Iso 3

Gate A

2 0

C 30 see CODE Table 3 Supp. 1 1304.23 1304.70 CV-5612 FIRE RB Iso 3

Gate

'A 2

0 C

30 sec CODE Table 3 Supp. 1 1304.23 1304.70 CV-1065 CS Quench Tank Iso 3

Gate A

2 0

C 20 see CODE Table 3 Supp. 1 1304.23 1304.70 CV-1667 N2 N2 Supply 1

Globe

'A 2

0 C

20 see CODE Table 3 Supp. I 1304.23 1304.70 CV-6202 CW Inlet Iso i 6

' ate A

2 0

C 30 see CSD*

Table 3 Supp. 2 Revision 0 1005.08 December 19, 1978

Page 10 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING LitlITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE' PROCEDURE VALVE NO.

SYSTEtl DESCRIPTION (TN)

TYPE CAT CLASS POS.

POS

' TI tlE EXERCISE LEAK EXERCISE 1304.23 1304.70 CV-6203 CW Outlet Iso 6

Gate A.

2 0

C 30 sec CSD*

Table 3 Supp. 2 1304.23 1304.70 CV-6205 CW Outlet Iso 6

Gate A

2 0

C 60 sec CSD*

Table 3 Supp. 2 "D" Dil Rm 1104.04 CV-3800 SW Cooler Inlet 3

Gate B

3 C

0 90 cec CODE NA Supp. 2 "B" DII Rm,

1104.04 CV-3801 SW Cooler Inlet 3

Gate B

3 C

0 90 see CODE NA Supp. 1 "C" DII Rm 1104.04 CV-3802 SW Cooler Inlet 3-Gate B

3 C

0 90 see CODE NA Supp. 1 "A" Dl! Rm 1104.04 CV-3803

,SW Cooler Inlet 3

Gate B

3 C

0 90 see CODE NA Supp. 2 1104.05 CV-3804 SW E47A Spray'P 1

Gate B

3 C

0 20 sec CODE NA Supp. 3 1104.05 CV-3805 SW E47B Spray P 1

Gate B

3 C

0 2 sec CODE NA Supp. 5 1104.05 CV-3805 SW-E47B Spray P li Gate B

>3 C

0 20 see CODE NA Supp. 5 1104.02 Emergency Diesel CV-3806 SW "A" Cooler Inlet 6

Gate B

3 C

0 120 see CODE NA Supp. 2 Emergency Diesel CV,-3807 SW "B" Cooler Inlet 6

Gate B

3 C

0 120 sec CODE NA MU Pump LO 1104.02 CV-3808 SW Clr Inlet A 3

Cate B

3 C

0 90 see CODE NA Supp. 4 l

Revisiou 0 1005.08 December 19, 1978

Page 11 of 15

_ ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING

~~~

LIMITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE' PROCEDURE VALVE N0.

_ SYSTEM DESCRIPTION (IN)

TYPE CAT CLASS POS POS TIME EXERCISE LEAK EXERCISE MU Pump LO 1104.02 CV-3809 SW Cooler Inlet B 3

Gate B

3 C

0 90 sec CODE NA Supp. 2 MU Pump LO 1104.02 cv'-3810 SW Cooler Inlet C 3

Gate B

3 C

0 90 sec CODE NA Supp. 3 1104.04 CV-3821 SW B-DH Cooler Outlet 12 Btfly B

3 C

0 45 see CODE NA Supp. 2 1104.04 CV-3822 SW A-DH Cooler Outlet 12 Btfly B

3 C

0 45 sec CODE NA Supp. 1 A-DIf. Lube Oil 1194.04 CV-3840 SW Cooler Outlet 1

Gate B

3 C

0 20 sec CODE NA Supp. 1 A-DH Lube Oil 1104.04 CV-3S41

,SW Cooler Outlet 1

Gate B

3 C

0 20 sec.

CODE NA Supp. 2 l VUC-2B ES SW 1304.70 CV-3900 SW Gear Rm Clr Inlet 3

Gate B

3 C

0 20 see CODE NA Supp. 'l VUC-2B ES SW 1304.70 CV-3902 SW Gear Rm Clr. Outlet 3

Gate B

3 C

0 20 see CODE NA Supp. 1

-t VUC-2D ES 1304.70 CV-3903 SW-Gear Rm Clr Inlet 3

Gate B

3 C

0 20 see CODE NA Supp. 1 VUC-2D ES SW 1304.70 CV-3905 SW Gear Rm Clr Outlet 3

Gate B

3 C

0 20 sec CODE NA Supp. 1 SW Loop II 1304.70 CV-3811 SW Iso to ICW 14 Btf y B

3 0

C 60 sec CSD*

NA Supp. 2 SW Loop I 1304.70 CV-3320 SW Iso to ICW 14 Btfly B

3 0

C 60 see CSD*

NA Supp. 2 Revision 0 1005.08 December 19, 1978

Page 12 of 15 ENCLOSURE 2 UNIT 1 VALVES REQU'ETNG INSERVICE TESTING 7

Lit!ITING

(

SIZE IWV NOR ACC CLOSE TESTING PROCEDURE' PROCEDURE VALVE NO.

SYSTEM DESCRIPTION (IN)

TYPE CAT CLASS POS POS TIllE EXERCISE LEAK EXERCISE Cross-tie SW

'1304.70 CV-3640 SW B to C Discharge 18 Btfly B

3 C

60 sec CSD*

NA Supp. 2 1304.70 CV-3641 SW Loop II Iso 18 Btfly B

3 C

'9 see CSD*

NA Supp. 2 Cross-tie SW 1304.70 CV-3642 SW B to C Discharge 18 Btfly B

3 C

60 sec CSD*

NA Supp. 2 1304.70 CV-3643 SW Aux C1g Loop Iso 18 Btfly B

3 0

C 60 see CSD*

NA Supp. 2 Cross-Tie SW 1304.70 CV-3644 SW A to B Discharge 18 Btfly B.

3 C

60 see CSD*

NA Supp. 2 1304.70 CV-3645 SW Loop I Iso 18 Btfly B

3 0

60 see CSD*

NA Supp. 2 Cross-tie SW 1304.70 CV-3646 SW A to B Discharge 18 Btfly B

3 C

60 sec CSD*

NA Supp. 2 RB Cooler 1104.33 CV-3812 SW SW Inlet 10 Btfly B

2 C

0 30 see CODE NA Supp. 3 RB Cooler 1104.33 CV-3813 SW SW Inlet 10 Btfly B

2 C

0 30 see CODE NA Supp. 3 1104.33 RB C<,oler CV-3814 SW SW Outlet 10 Btfly B

2 C

0 30 sec CODE NA Supp. 3 RB Cooler 1104.33 CV-3815 SW SU Outlet 10 Btfly B

2 C

0 30 see CODE NA Supp. 3 1304.23 1304.70 2

Gate A

2 C

0 30 sec coaa Table 3 Supp. 1 CV-7443 HVAC Hydrogen Purge j

Revision 0 1005.08 December 19, 1978

Page 13 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING 1

LIMITING VALVENO.l SYSTEM SIZE IWV NOR ACC CLOSE TESTING PROCEDURE PROCEDURE DESCRIPTION (IN)

TYPE CAT CLASS POS POS TIME EXERCISE LEAK EXERCISE 1304.23 1304.70 CV-7444 IIVAC IIydrogen Purge 2

Gate A.

2 C

0 30 sec icoog Table 3 Supp. 1 1304.23 1304.70 CV-7445 IIVAC llydrogren Purge 2

Gate A

2 C

0 30 sec CODE Table 3 Supp. 1 1304.23 1304.70 CV-7446 IIVAC IIydrogen Purge 2

Gate A

2 C

0 30 sec CODE Table ~3 Supp. 1 1304.23 1304.70 CV-7447 IIVAC Ilydrogen Purge-2 Gate A

2 C

0 30 sec CODE Table 3 Supp. 1 1304.23 1304.70 CV-7448 IIVAC IIydrogen Purge 2

Gate A

2 C

0 30 sec CODE Table 3 Supp. 1 1304.23 1304.70 CV-7449

, IIVAC lIydrogen Purge 2

Gate A

2 C.

0 30 sec.

CODE Table 3 Supp. 1 1304.23 1304.70 CV-7450 llVAC llydrogen. Purge 2

Gate A

2 C

0 30 sec CODE Table 3 Supp.el Air Particulate 1304.23 1304.70 CV-7453 IIVAC Monitor 1

Globe A

2 0

C 30 sec CODE Table 3 Supp. 1 Air Particulate 1304.23 1304.70 CV-7454 IIVAC Monitor' 1

Globe A

2 0

C 60 see CODE Table 3 Supp. 1 PSV-1000 RCS Pz Relief 2

1 0

j CV-1404 Dil Dll Pump Suction 12 Gate 2

0 Operator Controlled g

gg Dil Removal CV-1410 Dil From Reactor 12 Gate Operator Controll :d

_.___1_____

Revision 0 1005.08 December 19, 1978

Page 14 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING

~~~

~~

LIMITING SIZE IWV NOR ACC CLOSE TESTING PROCEDURE' PROCEDURE VALVEhj0._

SYSTEM DESCRIPTION (TN)

TYPE CAT CLASS POS POS

~ TIME EXERCISE LEAK EXERCISE RCB CV-1414 DH Sump Suction 14 Gate 0pc ator Con. rolled 77 jg,y 7

RCB jg7 CV-3415 DH Sump Suction 14 Gate Ope cator Con trolled

_7 CV-1428 DH Cooler Outlet 10 Globe Ope rator Controlled pgq

~

CV-1429 DH Cooler Outlet 10 Globe Operator Controlled jpg, p g,j CV-2415 CF CFT Outlet 14 Gate Locked in Position CV-2419 CF CFT Outlet 14 Gate Locked in Position 1304.23 CV-4100 DWD RB Sump Drain 4

Gate A

?

C C

NA NA Table 3 NA e 1304.23 CV-4446 DWD RB Sump Drain 4

Gate A

2 C

C NA NA Table 3 NA RB Vent to 1304.23 CV-4803 GZ-Gaseous Waste 2

Globe

'A 2

C C

NA NA Table 3 NA RB Vent to 1404.23 CV-4804 GZ Gaseous Waste 2

Globe A

2 C

C NA NA Table 3 NA 1304.23 CV-7401 VSF RB Purge Air 54 Btfly

  • A 2

C C

NA NA Table 3 NA 1304.23

!CV-7402 VSF RB Purge Air 54 Btfly A

2 C

C NA NA Table 3 NA Revision 0 1005.08 December 19, 1978

Pdge 15 of 15 ENCLOSURE 2 UNIT 1 VALVES REQUIRING INSERVICE TESTING

~

LltilTING

~

SIZE IWV NOR ACC CLOSE TESTING PROCEDURE PROCEDURE

, VALVE NO.

SYSTEf!

DESCRIPTION (IN)

TYPE CAT CLASS POS.

PDS TIllE EXERCISE LEAK EXERCISE 1304.23 CV-7403 VSF RB Purge Air 54 Btfly A

2 C

C NA NA Table 3 NA

[___

1304.23 CV-7404 VSF RB Purge Air 54 Btfly A

2 C

C NA NA Table 3 NA Ci.-49 CA Na0l! Tank Outlet 4

Gate E

2 Loc ked Open NA NA Combined SW Loop gg 7 CV-3823 SW Discharge to Pond 18 Btfly E

3 Opc rator Cor trolled Combined SW Loop ggg g C'!-3824 SW Discharge to Flume 18 Btfly E

3 Opera to r. Cor trolled g

ggg l

P

-~

Revision 0 1005,08 December 19, 1978

FOOTNOTES FOR ENCLOSURE TWO This indicates that we have requested relief in Enclosure 1.

+

These valves cannot be operated during normal plant operation and shall be full-stroke exercised during each cold shutdown as required by IWV-3520 (b).

O 4

O e

4 O

e e

ENCLu..URE 3 EXPLANATION OF WHY VALVES CANNOT BE STROKED DURING NORMAL PLANT OPERATION CF 1 A 6 B, DH 13 A 6 B, DH 14 A 6 B, DH 17 and DH 18 - Valves cannot be lifted against reactor pressure.

MU 34 A, B, C 6 D - Testing would the: mally shock HPI -nozzels.

CV 2691 6 2692. Stroking during normal oepration would cause a reactor trip due to high RC pressure and/or temperature.

CV 1214, 1216, 1221 - Failure of these valves in closed position during test would necessitate stopping RC pwnp seal injection and the RC pimps.

CV 1219, 1227, 1228 - If RCS pressure exists down stream of these valves, one check' valve is all that protects low pressure piping upstream.

CV 1220 - RCS pressure exists downstream of this valve due to make-up in-jection.

Testing during normal oepration would result in high pressure.

bcing applied to upstream check valve, and if this check valve failed, the pressure in piping upstream would exceed design conditions.

CV 1270,.1271,1272,1273 and 1274 - Failure of these valves in a closed

- position during test could result in damage to the RC pump seals.

CV 1300, 1301 - Closing either of these valves during normal. operation would damage the operating make-up pump.

CV 1400, 1401 - If RCS pressure exists downstream of these valves, opening them would damage the. low pressure injection system.

CV 1405, 1406-Stroking these valves would allow a partial draining of LP.I and HPI pump suction piping.

Should ES actuation occur during a test, the HPI and LPI pumps would be damaged.

BS 4 A 6 B - These valves are immediately upstream of the RB. spray nozzels.

Water flow cannot be used for stroking these. check valves.

Stroking requires draining lines inside the reactor building which is impractical.during normal operation.

CV 2630, 2680 - Stroking during normal operation would result in a reactor trip due to high power or high pressure.

FW 7 A.6 B - Closing these valves during normal oepration would stop feedwater flow to a steam generator.

Loss of heat sink to either RCS loop would cause high pressure and temperature.

Eittar.of these conditions would trip the reactor.

FW 13 A 6 B - Cold emergency feedwater cannot be introduced into a steam generator without upsetting the feedwater control system and causing a-reactor trip.

CV 2214, 2215, 2233 - Closing these valves during normal operation would increase letdown temperature and cause isolation of the letdown system.

Without letdown, seal injection would raise the pressurizer level above safe operating limits.

CV 2220, 2221 - Failure of either valve in a closed position would require stopping all RC pumps and de-energi ing the control rod drives.

CV 2234 - Failure in a closed position would result in the loss of cooling for the RC pump motor air and lube oil coolers. Without this cooling, all RC pumps would have to be stopped.

CV 2235 - Failure in a closed position would require de-energizing the control rod dri.es.

CV-6202, 6203, 6205 - Failure of one of these valves in a closed position would trip the main chillers.

CV 3640, 3641, 3642, 3643, 3644, 3645, 3646, 3811, 3820 - Testing these valves during normal operation would result in inadequate flow to components at high elevations due to reductions in service water flow.

BW 2, BW 3 - Testing during normal operation would berate the RCS and cause control rod positioning outside Tech. Spec. limits.

4

.