ML19256A602

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Deviation Noted in Insp Rept 70-754/78-09
ML19256A602
Person / Time
Site: 07000754
Issue date: 12/29/1978
From: Book H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Darmitzel R
GENERAL ELECTRIC CO.
Shared Package
ML19256A592 List:
References
NUDOCS 7901090079
Download: ML19256A602 (1)


Text

. p [ I ",, %

UrJt T ED STATES

[

NUCLEMI It EGU LATOf t Y COMMISSION

,,k j',,,,

h ' k l.3,.

.h HEGIOfJ V

'F4 LUt T E 202. W ALr4U T C RE E K PL AZ A

'[

3990 N. C AllF OHtil A BOULEV ARD Y

  1. eep9 W AlfeUT CREEK, C AllFORNI A 94$96 Docket flo.70-754 DEC 2 91978 General Electric Company Vallecitos ttuclear Center P. O. Box 460 Pleasanton, California 94566 Attention:

Mr. R. W. Darr:1tzel, Manager Irradiation Processing Operation Gentlenien:

Thank you for your letter dated December 18, 1978 informing us of the steps you have taken to correct the item which we brought to your attention in our letter dated flovember 2, 1978.

Your corrective actions will be verified during a future inspection.

Your cooperation with us is appreciated.

Sincerely, H. E. Book, Chief Fuel Facility and Materials Safety Branch 790100007S