ML19256A552
| ML19256A552 | |
| Person / Time | |
|---|---|
| Site: | Westinghouse |
| Issue date: | 12/14/1978 |
| From: | Damore M, Goodwin W WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP. |
| To: | Kenna W NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| Shared Package | |
| ML19256A549 | List: |
| References | |
| NUDOCS 7901090004 | |
| Download: ML19256A552 (1) | |
Text
s
.)
Westinghouse Electric Corporation aun I, a: bt "tr,y g;;,.3 7,mg)
C
j P:R //62613 Decarber 14, 1978 U. S. Nuclear Ibgulatory Conmission Attn:
Mr. W. B. Kenna, Chief Ibgion II Safeguards Branch Office of Inspection and EnforccTent 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 IE : RII: JWB 70-1151/78-13
Dear Mr. Kenna:
In response to your letter of Novater 22, 1978, concerning your inspection of our facilities conducted Novmber 1-3, 1978, and pursuant to the provisions of Section 2.201 of the NIC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, Westinghouse ccTents are transmitted herewith as Appendix A.
This appenchx should be withheld fran public disclosure in accardance with Section 2.790(d) of the NIC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations.
If you should have any questions regarding this nutter, please write to Mr. Harold Foster or me at the above address, or telephone either of us on (803) 776-2610.
Sincerely, WESTINGIOUSE ELEC1'RIC 03RPORATION h/
7hc W. L. Goodwin, Bhnager Pegulatory Ct;rpliance f}rj'o) ldv w~
bbad D'Anore, Fhracer Funufacturing and Coltrabia Plant amh Attactrent 790109000'
smuttmHSWfsihRMM cogpD sT ATEsnD WOREDON ja mico
'o NUCLEAR REGULATORY COMMISSION
[
g REGloNil
{
, f. (
g 101 M ARIETT A STREET, N.W
' ' r ATL ANT A. GEORGI A 30307 o
's,..... J In Reply Refer To:
NOV 221978 RII:JWB 70-1151/78-13 Westinghouse Electric Corporation Attn:
Mr. M. D'Amore, Manager Columbia Plant Nuclear Fuel Division Drawer R Columbia, South Carolina 29205 Gentlemen:
This refers to the inspection conducted by J. W. Bates of this office on of activities authorized by NRC License No. SNM-1107 November 1-3, 1978, at Westinghouse Electric Corporation and to the discussion of our findings the conclusion of the insoection.
held with Mr. M. D'Amore at The area examined during this inspection was your program for safeguarding special nuclear material under the acolicable provisions of Title 10, Code of Federal Regulations, Part 70, "Special Nuclear Material," and specific Within this area, the inspection con-requirements of the above license.
sisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspectors.
We have examined actions you have taken with regard to previously identi-These are discussed in the enclosed inspection fied enforcement taatters.
report.
During the inspection, it was found that certain activities under your These items license appear to be in noncompliance with NRC recuirements.
and references to pertinent requirements are listed in the Notice of This notice is sent to you Violation enclosed herewith as Appendix A.
to the provisions of Section 2.201 of the NRC's " Rules of Practice,"
pursuant Section 2.201 recuires you 2, Title 10, Code of Federal Regulations.
Part of this notice, to this office, within 20 days of your receipt to submit (1) corrective steps a written statement or explanation in reply including:
(2) corrective steps which have been taken by you and the results achieved; the date when which will be taken to avoid f urther noncompliance; and (3)
Details of activities involving safe-full compliance will be achieved.
from disclosure in accordance with guards and security measures are exemptTherefore, your response should be incorp 10 CFR 2.793(d).
separate paper and referenced in your reply.
bd5 15 \\>l& cW{
O m m ut musufa ga m m 90 MORET)0N
~
MATalAlTRANSMTflIDliGEWIDI C0H1 AINS 2.790INFORMADON Westinghouse Electric Corporation NW 22 WM In accordance with Section 2.790(d) of the NRC's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, activities involving safeguards and security measures are exempt from public disclosure; therefore, the enclosures to this letter with the exception of the report cover page, which is an inspection summary, will not be placed in the Public Document Room.
Should you have any questions concerning this letter, we will be glad to discuss them with you.
Sincerely,
/
/
.y4 W
'f Av'. B. Ken a, Chief Safeguard Branch
Enclosures:
1.
Appendix A, Notice of Violation (Exempt from Disclosure) 2.
Inspection Report No. 70-1151/78-13 (Exempt from Disclosure) 3.
Inspection Summary (Not Exempt) e TERIAlTRANSMM N COMIMMS 2.190 MW